EH4700 Series Envir onmental Enclosur es Installation/ Operation Manual C1405M-E (11/03) Pelco • 3500 Pelco Way, Clovis • CA 93612-5699 USA • www.
2 Pelco Manual C1405M-E (1 1/03) CONTENTS Section Page GENERAL....... ................................................................................................... 3 IMPORT ANT SAFEGUARDS AND WARNINGS ....................................... 3 DESCRIPTION .
Pelco Manual C1405M-E (1 1/03) 3 Please thoroughly familiarize yourself with the information in this manual prior to installation and operation. GENERAL IMPORT ANT SAFEGUARDS AND W ARNINGS Prior to installation and use of this product, the following W ARNINGS should be observed.
4 Pelco Manual C1405M-E (1 1/03) DESCRIPTION Environmental enclosures in the EH4700 Series are used with pan/tilt units or fixed mounts. The enclosures are constructed of aluminum. Y ou can install cameras with either fixed focal length lenses or motorized zoom lenses (up to 10X).
Pelco Manual C1405M-E (1 1/03) 5 INST ALLA TION 1. Unlatch and raise the enclosure lid. The gas spring will hold the lid in place when it is fully opened. 2. Remove the camera sled from the rail: a. Loosen the screws. b. Slide the sled so that the screws are in the large part of the mounting holes.
6 Pelco Manual C1405M-E (1 1/03) c. Move the fan out of the way and remove the fan shroud. d. T urn the fan around so that it blows toward the viewing window (refer to the arrows on the fan). e. Reinstall the fan on the back of the enclosure. f. Close the enclosure lid.
Pelco Manual C1405M-E (1 1/03) 7 Figure 2. EH4700 Series Input Wiring Diagram CAMERA POWER 24/120/230 V AC (SUPPLIED WITH PCB) * CAMERA POWER INPUT TO CAM 2* CAMERA POWER (SUPPLIED WITH PCB) * * CONNECT CAM 1 TO CAMERA WHEN CAMERA'S POWER IS THE SAME AS THE AC POWER INPUT .
8 Pelco Manual C1405M-E (1 1/03) b. Wire the 10-connector INPUTS terminal on the circuit board to the lens controller as follows: • Lens Common - Connector 1 • Focus - Connector 2 • Zoom - Conne.
Pelco Manual C1405M-E (1 1/03) 9 Maximum distance from transformer to load T able A. 24 V AC Wiring Distances The following are the recommended maximum distances for 24 V AC applications and are calculated with a 10-percent voltage drop. (T en percent is generally the maximum allowable voltage drop for AC-powered devices.
10 Pelco Manual C1405M-E (1 1/03) 13. EH4718-1, -2, -3 Models, and EH4722-1, -2, -3 Models Only - Wire power to the enclosure to operate accessories (and the camera if its power is con- nected to CAM 1 on the circuit board) as follows: a. Remove the plastic cover over the power supply section of the circuit board.
Pelco Manual C1405M-E (1 1/03) 11 OPERA TION If your enclosure has a thermostatically controlled blower , the thermostat is set to turn the fan on between 77 ° and 93 ° F (25 ° and 34 ° C) and to turn the fan off between 62 ° and 78 ° F (17 ° and 26 ° C).
12 Pelco Manual C1405M-E (1 1/03) MAINTENANCE Perform the following maintenance at regularly scheduled intervals to prolong the operational life and appearance of the equipment. 1. Clean the window with a mild nonabrasive detergent in water and a soft cloth to maintain picture clarity .
Pelco Manual C1405M-E (1 1/03) 13 ELECTRICAL Input Voltage: 24, 120 or 230 VAC, 50/60 Hz Electrical Connections: One each of the following when equipped with optional circuit board (O/I-PCB): 3-connec.
14 Pelco Manual C1405M-E (1 1/03) (43.18 x 13.97 x 10.80 cm) EH4718-1, -2, -3 13" L x 4.75" W x 4.25" H (33.02 x 12.07 x 10.80 cm) EH4722 21" L x 5.5" W x 4.25" H (53.34 x 13.97 x 10.80 cm) EH4722-1, -2, -3 17" L x 4.
Pelco Manual C1405M-E (1 1/03) 15 increase inside enclosure with heater operating: With vent grills installed: 17 ° F (9.5 ° C) increase With vent covers and TI47 thermal installation: 25 ° F (13.8 ° C) increase With vent covers, TI47 thermal insulation and WD47 defroster installed: 35 ° F (19.
16 Pelco Manual C1405M-E (1 1/03) REVISION HISTOR Y Manual # Date Comments C1405M 10/94 Original version. C1405M-A 12/94 Revised to include new PCB9000276 wiring diagram and parts list as per ECO#94-578. C1405M-B 8/95 Revised Figure 1 to include new PCB9000277ASSY per ECO# 95-255.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Pelco c1405M-E è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Pelco c1405M-E - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Pelco c1405M-E imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Pelco c1405M-E ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Pelco c1405M-E, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Pelco c1405M-E.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Pelco c1405M-E. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Pelco c1405M-E insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.