INST ALLA TION 090 Series Camclosure ® Indoor Integrated Camera System C2462M-D (3/08) Surface Mount/In-Ceiling.
.
C2462M-D (3/08) 3 Contents Important Safety Instructi ons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . .
4 C2462M-D (3/08) List of Illustrations 1 How to Remove the Dome Bubble . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2 Ceiling/W all In stallation . . . . . . . . . . . . . . . . . . . . . .
C2462M-D (3/08) 5 Important Safety Instructions 1. Installation and servicing should be d one only by qualified se rvice personnel and conform to all local codes.
6 C2462M-D (3/08) Description The ICS090 Series Camclosure ® integrated camera system integrates a camera and lens package in a small, discreet dome. The system is easy to install and can be mounted or recessed to the surface of a ceiling or wall.
C2462M-D (3/08) 7 Remove the Dome Bubble T urn the dome bubble counterclockwise and lift (refer to Figure 1). Place the b ubble on a nonabrasive surface. If the unit is supplied with a dome liner , remove the li ner b efore installing the un it. T o re move the liner , gently lift it from the unit.
8 C2462M-D (3/08) Install the Back Box The installation methods for the ICS090 Series include the following options: • Mount to the surface of a ceiling or wall • Install in a suspended ceiling .
C2462M-D (3/08) 9 4. Use the 6-32 toggle bolts (not supplied) to at tach the surfa ce mount ring and back box to the mounting surface, refer to Figure 2. NOTE: For a concrete ceiling/wall installation, use 8-32 mounting hardware (not suppl ie d), refer to Figure 3.
10 C2462M-D (3/08) IN-CEILING INSTALLATION: SUSPENDED CEILING Refer to Figure 4 and complete the following steps. 1. Remove the ceiling tile from the ceiling. 2. Cut a 4-inch diameter h ole in the ceiling tile. 3. Remove the surface mount ring from the back box.
C2462M-D (3/08) 11 Figure 5. How to Remove Surfac e Mount Ring from Back Box AC operation only: If you are wiring more than one ICS090 Camclosure to the same transformer , connect one side of the transformer to the red wire on all units, and then connect the other side of the transformer to the black wire on all units.
12 C2462M-D (3/08) IN-CEILING INSTALLATION: FIXED CEILING/W ALL Refer to Figure 6 and complete the following steps. 1. Cut a 4-inch diameter h ole in the ceiling/wall. 2. Remove the surface mount ring from the back box. Refer to Figure 5 and complete the following steps: a.
C2462M-D (3/08) 13 INSTALLATION TO THE SURF ACE OF A 4S STANDARD ELECTRICAL BOX Refer to Figure 7 and complete the following steps. 1. Attach the adapter ring to the 4S box with the two 8-32 x 1.00-inch screws (s upplied). 2. Connect the video cable/wires.
14 C2462M-D (3/08) INSTALLATION IN A 4S DEEP ELECTRICAL BOX Refer to Figure 8 and complete the following steps. 1. Remove the surface mount ring from the back box. Refer to Figure 5 and complete the following steps: a. Place your fingers on the circular marks loca ted on the sides of the surface mount ring.
C2462M-D (3/08) 15 Camera Positioning Manually rotate and tilt th e camera module to positio n the camera. Do not over- rotate the module. Figure 9. Positioning the Camera WAR NI NG : Excessively turning the module in one direct ion could result in damage to the wiring.
16 C2462M-D (3/08) Camera Adjustments SWITCH SETTINGS SWITCH SETTINGS FOR FIXED FOCAL LENGTH LENS WITHOUT AUTO IRIS Refer to the switch drawing. The switch is located n ext to the lens.
C2462M-D (3/08) 17 V ERTICAL PHASE ADJUSTMENT (24 V AC OPERATION ONLY) When using more than one camera power supply, a brief vertical roll may occur on the monitor when a camera view is switched. T o elim inate vertical roll, reverse the 24 V AC connections on one camera.
18 C2462M-D (3/08) Reinstall the Dome Bubble DOME LINER INSTALLATION If the unit is supplied with a dome liner , reinsta ll t he liner before installing the dome bubb le. T o install the liner , refer to Figure 11 comp lete the following steps: 1. Align the studs located on the camera module with the clips on the liner .
C2462M-D (3/08) 19 DOME BUBBLE INSTALLATION T o insta ll the dome bubble refer t o Figure 12 and complete the fo llowing steps: 1. Select the bubble (clear or smoked). 2. Align the standoffs of the bubble with the slots of the back box. 3. T urn the bubble clockwise, until it locks in place.
20 C2462M-D (3/08) Service Connector An optional 4-foot service/monitor cable, part numb er ICS090-SC, is available for on- site setup and adjustments. T o use the cable simply plug one end of the cable directly into the service connector of the ICS090, and then connect the other end to any st andard BNC (VIDEO IN) connector on a monitor .
C2462M-D (3/08) 21 Specifications BACKBOX Electrical Input V oltage 12 VDC or 24 V AC (±10%), autosensing Power Consumption 3 W or less Video Connector BNC General Pan/T ilt Adjustment Pan 360° T il.
22 C2462M-D (3/08) The materials used in the manufacture of this document an d its components are compliant to th e requirements of Directiv e 2002/95/EC.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, witho ut charge, any mer c handise proved defective in ma terial or wo rkmanship for a period of one year after th e date of shipment.
Worl dwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Pelco 90 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Pelco 90 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Pelco 90 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Pelco 90 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Pelco 90, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Pelco 90.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Pelco 90. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Pelco 90 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.