IPD1-A2-GZ40-10 July 2005 1 12000E IP Br oadband Loop Carrier Installation Instructions Document Number IPD1-A2-GZ40-10 Ju ly 2005 Contents Softwar e and Firmware License Ag reement .......... ................ ............. ............... 1 Introductio n .
2 July 2005 IPD1-A2-GZ40-10 e xecuted a separ ate wr itten agreem ent cov ering the Software supplied to you under this purchase , such separate written agr eement shall gov er n.
IPD1-A2-GZ40-10 July 2005 3 9. Upon such termination, the Licensee shal l refrain from an y fur ther use of the Softwar e and destro y the original and all copies of the Softw are in the possession of L icensee togethe r with all documentat ion and relate d materials.
4 July 2005 IPD1-A2-GZ40-10 If there is visib le damage, do not attempt to conne ct the de vice. Contact y our sales representat ive . Installation Options The 12000E BL C is designed f or installation in a Restricted Access area where admittance is limited t o trained and author ized se r vice personel.
IPD1-A2-GZ40-10 July 2005 5 Installing in a Rack Procedur e 1. Using a Phillips screwdriv er , attach the two provided r ac k mo unt brac kets to the sides of the 1200 0E with eight of the ten pr ovided br acket scr ews .
6 July 2005 IPD1-A2-GZ40-10 2. Mount the chassis onto the r ac k and secure the rac k mount brac kets to the sides of the rack using one of the two provided set s of eight rac k screws (whichev er size fits the rack being utiliz ed).
IPD1-A2-GZ40-10 July 2005 7 Procedur e 1. Select a slot f or installation. The 12000E is a f our teen slot chassis: slots 1–12 are reserved f or interf ace modules and slots U1–U2 are rese r ved f or management modules .
8 July 2005 IPD1-A2-GZ40-10 2. With the manageme nt module printed circu it board (PCB) f acing right and the management mo dule model name upright, align the upper and lo wer edges of the PCB with the slot module guides . 3. Slide the management mo dule firmly into the chassis .
IPD1-A2-GZ40-10 July 2005 9 Installing Y our Interface Module(s) Interf ace modules prov ide the subscriber connections f or an 12000E; up to twelv e interf ace modules may b e installed in the 1200 0E (slots 1–12).
10 July 2005 IPD1-A2-GZ40-10 3. Slide the interf ace module firmly into the chassis . Tighten the f astening scre ws on the interface module f aceplate.
IPD1-A2-GZ40-10 July 2005 11 P owering Up Y our 12000E CA UTION: T ur n your DC po wer source(s) OF F until y ou hav e completed connection of the 12000E as outlined in the f ollowing sections . Do not opera te the 12000E withou t a ground conn ection.
12 July 2005 IPD1-A2-GZ40-10 3. Select a terminal bloc k. Either ter minal bloc k on the back of the 12000E ma y be used to power the chassis; only one te rm inal bloc k is required f o r operat ional purposes. The two terminal b locks on the 12000E are independent f eeds.
IPD1-A2-GZ40-10 July 2005 13 4. Using a Phillips screwdriv er , remov e th e left-hand screw from the chosen terminal bloc k (labeled "+" on the chassis). Slide the ring terminal of your positiv e power lea d around the sh aft of the scre w and insert the scre w into the same "+" terminal from which it was remov ed.
14 July 2005 IPD1-A2-GZ40-10 7. V er ify the connection. T ur n your po wer source(s) on. The PWR (po wer) LED on the interf ace module and management module f a ceplates will illuminate solid green to indicate the m odules are receiving po wer .
IPD1-A2-GZ40-10 July 2005 15 Connecting Y our Subscriber Lines No configuration is necessary f or the interf ace module(s) installed in y our 12000E to operate at def ault settings . How ev e r , if you wish to run y our subscriber connections at se ttings other than the de f aults, co nfigure the interf ace module(s) prior to connection.
16 July 2005 IPD1-A2-GZ40-10 2. Detach the hook-an d-loop f astener strap fr om the f emale RJ21 connector port: lift the hook -and-loo p fastener tab on the le ft and pull t he strap open towards the r ight, leaving it loop ed under th e r ight side o f the conn ector frame.
IPD1-A2-GZ40-10 July 2005 17 5. V er ify the connection(s). The LK (Link) LED f or each por t being connected with a remote modem will illuminate solid or flashing green (depending on the interf ace module model) to indicate a connection has be en established .
18 July 2005 IPD1-A2-GZ40-10 Conf iguration and Management Although no configu ration is necessary to run subscriber lines at the defa ult settings , all 12000E parameter settings are software se lect.
IPD1-A2-GZ40-10 July 2005 19 F an Module The 12000E f an module is installed horizontally abo ve the interf ace module slots. It comes pre-installed an d should not be remo ved unless it is being replaced.
20 July 2005 IPD1-A2-GZ40-10 Specif ications T able 1. Specifications Specif ication Criteria Environment Operatin g T emperature: –40° F to 149° F (–40° C to 65° C) Storage T emperature: –40° F to 158° F (–40° C to 70° C) Humidity: 5 % to 95 %, non-condensing Altitude: –200 ft to 16,500 ft (–60 m to 5,000 m) Physical 15.
IPD1-A2-GZ40-10 July 2005 21 Important Safety Instructions 1. Read and f ollow all warning notices an d instructions marked on the produ ct or included in the man ual. 2. Do not attempt to ser vice this product y ourself, as opening or remo ving cov ers ma y expose you to dangerous hig h voltage points or o ther r isks.
22 July 2005 IPD1-A2-GZ40-10 12. In addition, if the equipment is to be used with telecommuni cations circuits , take the f ollowing precautions: — Ne v er install telephone wiring during a lightning storm. — Nev er install telephone jacks in wet lo cations unless the jack is specifically designed f or wet locations .
IPD1-A2-GZ40-10 July 2005 23 CANAD A – EMI NO TICE: ! This Class A digi tal apparatus meet s all requirements of the Canadian interferen ce-causing equipment regula tions. Cet appareil n umérique de la c lasse A respecte toutes les e xig ences du règlement sur le matérial br ouilleur du Canada.
24 July 2005 IPD1-A2-GZ40-10 *IPD1-A2-GZ40-10* *IPD1-A2-GZ40-10*.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Paradyne 12000E è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Paradyne 12000E - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Paradyne 12000E imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Paradyne 12000E ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Paradyne 12000E, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Paradyne 12000E.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Paradyne 12000E. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Paradyne 12000E insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.