FP2/FP2SH Series Programmable Controllers 09/2007.
T op Performance, Full Range of Functions CPU Units 2 CPU units Selectable from six types, according to the application There are six types of CPU units, including the standard type and the type with preinstalled commonly-used advanced functions. This selection allows for more economical system development according to the application.
T op Performance, Full Range of Functions 3 Flexible Expandability Memory and I/O Control Memory and I/O control Equipped with an adequate program memory and operating memory capacity The body is compact; however , the standard program memory capacity of FP 2/FP2SH is as large as 16k/60k steps, and when optional memory is added, 32k/120k steps.
4 Optimal Combination with Servo Drives Positioning 4 "RTEX" positioning units Compatible with Realtime Express MINAS A4N* network servo systems. Facilitate multi-axis high precision positioning High-accuracy multi-axis positioning control achieved by high-speed 100Mbps communication.
Optimal Combination with Servo Drives 5 High-Speed, High-Precision Positioning Positioning 2 axes: FP2-PN2AN 4 axes: FP2-PN4AN 8 axes: FP2-PN8AN Monitoring LEDs • Status indicator • Link status • Error indicator • Pulser input status Positioning units High-speed, high-accuracy pulse output type positioning unit.
6 Accurate Process Control Analog Control 6 x Analog control Multi-range control of a variety of equipment is possible. The units can be directly connected with thermocouples and resistance temperature detectors Support voltage/current/temperature sensor ranges The analog input unit supports voltage, current, and temperature sensors.
Accurate Process Control 7 Connect all PLCs with Each Other Networking FP2 multi-wire link unit FP2 multi-wire link unit FP2 multi-wire link unit FP2 multi-wire link unit Inverter Support a wide varie.
8 Continuous Communication in Industrial Applications Flexible Network Slave Unit 8 The Flexible Network Slave (FNS) unit is a powerful, modular network unit used together with the programmable con- trollers FP2 and FP2SH.
Continuous Communication in Industrial Applications Program/Operate the PLC using an Ethernet Network FP W eb-Server 9 The multifunctional FP W eb-Server provides users with the option of connecting any FP Series PLC to the Internet/Intranet for bi-directional communication via Ethernet.
10 Flexible Layout of I/O Devices Remote I/O Systems 10 Remote I/O systems MEWNET -F mode The number of I/O points can be increased up to 8192 and the transmission distance can be extended up to 700m by using the multi-wire link units. MEWNET -F is a remote I/O system that connects I/O units in separate locations with twisted-pair cables.
Flexible Layout of I/O Devices 1 1 Connect to V arious Serial Devices Serial Communication Serial communication control The CPU units have an RS232C port as standard equipment. The communication unit enables connections with RS232C/RS485/ RS422-compatible devices CPU units All CPU units have an RS232C port as standard equipment.
12 Basic CPUs FP2 12 The functions for a medium-scale PLC are squeezed into a compact body . Perfect when combining various devices. Features 1. Compact body The functions for a medium-scale PLC are squeezed into a compact body which requires minimal installation area (H: 100, W: 140, D: 108.
Basic CPUs 13 High-Performance CPUs FP2SH Serial Up to 1 backplane Units: 25 max. I/O points: 1,600 max. Remote I/O points: 8,192 max. Up to 3 backplanes Units: 32 max.
14 14 FP2/FP2SH Product Line and Accessories FP2/FP2SH system configurations and unit lineup Unit combinations Most units occupy one slot, i. e. module each, though some units occupy two slots. When selecting a backplane, carefully consider the units and number of slots you need.
15 Product Line and Accessories FP2/FP2SH FP2/FP2SH Product Line and Accessories Power supply units Input and output units Opti onal memor ies For FP2SH T ype of memory unit Analog input/output units Positioning units Multi- communication unit Pulse input/ output units Link-related units CPU units FP2SH Back plane s H type backplanes 100V AC, 2.
16 Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx 16 Control FPWIN Pro Programming According to the International Standard IEC 61 131-3 FPWIN Pro is the Panasonic programming software developed according to the international standard IEC 61 131-3 (for Windows 98, NT V4.
Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx 17 FP OPC Server and FP Data Analyzer Other software tools FP OPC Server Connects your favorite industrial application to FP2 or other FP Series PLCs The Panasonic FP OPC.
18 Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx 18 FP2-C2 FP2-C2P FP2-C3P F-ROM/EP-ROM Item Available Available 0.35 µ s or more 0.93 µ s or more 16k steps 32k steps Max.
Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx 19 Specifications FP2/FP2SH Note 1: Current inputs can be converted into voltage inputs by attaching the supplied external resistor to the input terminal section.
20 Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx 20 Note 1: Current inputs can be converted into voltage inputs by attaching the supplied external resistor to the input terminal section.
Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx 21 Specifications FP2/FP2SH ET -LAN units Multi-communication units Performance Specification T ransmission specifications for communication interface 16 − − − − − − Start-stop synchronization − − − − RS232C RS485 Note 1: The protocol can be downloaded from: www .
22 Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx 22 Multi-wire link units Performance Specification T ransmission specifications for communication interface 16 − − − − − − Start-stop synchronization − − − − RS232C RS485 Note 1: The protocol can be downloaded from: www .
Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx Item Transistor Line driver Output type Number of axes controlled Position command Speed command Acceleration/ deceleration command Home return Operation mode Startup time Output interface Feedback counter Other functions Internal current consumption (at 5 VDC) External power supply Command units Max.
24 Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx 24 CPU units (Built-in RAM) FP2 For FP2 FPSH From 0.35 µ s From 0.03 µ s 16k steps FP2-C1 FP2-C1D FP2-C1SL FP2-C2 FP2-C2P FP2-C3P 60k steps 60k steps 120k steps Not available Not available Not available Not available Available (See below .
Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx FP2-MW FP2-C1SL FP2-SL2 Number of I/O points Not insulated V oltage: 1 to 5V , -10 to +10V Current: 4 to 20mA, -20 to +20mA Insulated V oltages, currents, thermocouples, resistance thermometer devices R.
26 Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx 26 FP OPC Server FP OPC Server license FP Data Analyzer PCWA Y CommX Product name Description Product number Standardized connectivity to FP Series PLCs.
Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx 27 Dimensions FP2/FP2SH DIN rail mounting groove (35-mm wide DIN EN50022) * The illustration shows a conventional 7-module type backplane.
Copyright © 2007 • Printed in Germany 4193 euen 08/07 Asia Pacific China Japan North America Europe Global Network Panasonic Electric Works Please contact our Global Sales Companies in: Europe Headquarters Panasonic Electric W orks Europe AG Rudolf-Diesel-Ring 2, 83607 Holzkirchen, T el.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Panasonic FP2 Series è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Panasonic FP2 Series - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Panasonic FP2 Series imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Panasonic FP2 Series ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Panasonic FP2 Series, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Panasonic FP2 Series.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Panasonic FP2 Series. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Panasonic FP2 Series insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.