FP-X Series Strengthened Product Lineup to Meet Diversified Demands Programmable Controllers 01/2008.
High performance Network Inside of FP-X Comment memory Program memory Independent Max. 3 Ports Ethernet PLC-Link Computer Link Modbus-RTU General purpose serial communications Maximum number of I/O points Since up to 8 expansion units can be connected to 1 control unit, the maxi- mum number of I/O points is 300.
Positioning Product lineup 14 points 30 points 60 points 16 points 30 points � � � � � � � � � � � � � � � � � � � � � � � � � (Wi th ou t a p ow er s.
4 The highly expandable lineup satisfies a wide range of demands. Product lineup DC power supply AC power supply DC power supply AC power supply AFPX-C14RD AFPX-C14R AFPX-C14TD (NPN) AFPX-C14PD (PNP) .
5 Name and function of each part FP-X series RS232C tool port Expansion Unit (Model: Relay output type AFPX-E16R) Add-on Cassette (Model: Analog input cassette AFPX-AD2) I/O status monitor LED Connector for expansion unit Securing hole Connector for expansion unit Connector for double-stacked mounting * Only the communication cassette can be upper.
C14 C30, C60 C14 32 k 10 k 16 k FP0 FP-X C30/C60 FP-X 10k 20k 30k steps Processing speed of the basic instructions (ST , OR, AND, OT etc) 0.5 1.0 0.32 µ sec 0.9 µ sec µ sec FP-X FP0 Max. 8 units E30 E30 E30 C60 6 Equipped with an independent comment memory Equipped with an independent comment memory separate from the program memory .
C60 E16 E16 C60 E16 E30 NG O K C60 E16 E16 C60 E16 E30 NG O K E30 E30 C60 Max. 7 units (210 points) Max. 96 points E30 E30 C60 7 When further expansion or functions are required, use the existing FP0 expansion units All control units can be expanded by up to 3 FP0 expansion units via an adapter .
C14 A, upper A, lower C30 C60 B (Not attachable) A, upper A, lower A, upper A, lower B C Add-on Cassette Communication Cassette (Only one of these cassettes can be attached.) Part number Specifications Attachable position (see the figure below) A, lower A, upper B C Application Cassette Only a backup battery can be attached.
Tool port Tool port Tool port Ethernet RS232C Measuring instrument Measuring instrument Measuring instrument Touch panel Touch panel Touch panel Operation data managing software PCWAY RS232C RS232C Et.
10 FP-X perfectly fits the need for low cost “multi-axis positioning control in small-scale equipment”. Built-in 4-axis pulse output (T ransistor output type) The transistor output type C14 comes with 3-axis while C30/C60 comes with 4-axis pulse output inside the control unit.
Modbus-RTU Multiple temperature controllers Easy unification of data management FP-X T/C T/C T/C T/C T/C PI-D mode I-PD mode Time Target value Time Target value Time Target value Overshoot suppression.
* USB port is equipped with C30 and C60. PC P C USB cable direct connection The conventional RS232C port can also be used. AFPX-C30/C60 USB conversion cable RS232C/422 conversion adapter Previous Mode.
Master/ slave Master/ slave Master/ slave Master/ slave 13 FP-X series Another available application When 17 or more FP-X units need to be linked, the use of Modbus in - stead of MEWNET -W0 (see above) can accommodate up to 99 FP-X units.
FPWIN GR/Pro FP-X FP-X Master memory To the field operation Program transfer Program transfer Password used m Password locked Upload prohibited set m Upload prohibited Upload prohibited not set m Uplo.
15 FP-X series The most important highlights at a glance: 1 software for all FP Series PLCs. 5 programming languages (instruction list, ladder diagram, function block diagram, sequential function chart, structured text) available for all PLCs. Program organization units, task and project management provide clear structure.
16 FP-X series FP-X control unit FP-X expansion unit Product number list 100 to 240VAC 24VDC Power supply 24VDC 100 to 240VAC 24VDC 100 to 240VAC 24VDC Expansion FP0 Adapter FP-X E16R Expansio.
17 FP-X series FP-X add-on cassette FP-X options and service parts Product number list FP-X Input /Output cassette FP-X Input cassette FP-X Output cassette FP-X Pulse I/O cassette FP-X Analog .
18 FP-X series FP0 expansion units FP0 intelligent units FP0 link units Product number list Product name Connection type Product number Specifications Number of I/O points Power supply vol.
19 FP-X series Programmable display GT series FP memory loader FPWIN pro PLC programming software according to IEC 61 131-3 Other software tools Specifications Product name Product num.
20 FP-X series General specifications Power consumption, weight Specifications Item Description Rated voltage Operating voltage range Service power output Rush current Allowed momentary power .
Item Specifications Program method Control method Program memory Program capacity Operation processing speed Basic instructions Applied instructions External inputs (X) External outputs (Y) Internal r.
22 FP-X series Input specifications (control unit, expansion unit and add-on cassette) Relay output specifications (control units, expansion units) Note: *2 Please refer to the user manual for Y0 to Y7 of the transistor output type. Item Description Insulation method Output type Rated load voltage Load voltage allowable range Max.
Mounting dimension diagram H L2 2-M4 or 2-5 dia. Mounting dimensions for expansion (mm) L2 8 Type C14, E16 C30, E30 C60 L2 52 92 182 (Tolerance: ± 0.5) H 82 Panasonic Panasonic Panasonic L N max. min. max. min. max. min. max. min. FP-X C60 V1 V3 COM D Y12 Y1 1D PROG.
Global Network Copyright © 2007 • Printed in Ger many 4176 euen 11/07 Asia Pacific China Japan North America Europe Panasonic Electric W orks Please contact our Global Sales Companies in: Europe Headquarters Panasonic Electric Works Europe AG Rudolf-Diesel-Ring 2, 83607 Holzkirchen, T el.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Panasonic FP-X Series è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Panasonic FP-X Series - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Panasonic FP-X Series imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Panasonic FP-X Series ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Panasonic FP-X Series, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Panasonic FP-X Series.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Panasonic FP-X Series. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Panasonic FP-X Series insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.