2 1 Safety Precautions • Read the following “SAFET Y PRECAUTIONS” carefully before perform any servicing. • Electrical work must be installed or serviced by a licen sed elec trician. Be sure to u se the corr ect rating of the power pl ug a nd main circuit for the model installed.
3 17. After completion of installation or service, confirm ther e is no leakage or refrigerant gas. It may gener ate toxic gas when the refrigerant contacts with fire. 18. Ventilate if there is refrigerant gas leakage during operation. It may cause toxic gas when refrigerant contacts with fire.
4 2 S pecifications 2.1. CS-E9GFEW- 2 CU-E9GFE-2 ITEM UNIT INDOOR UNIT OUTDOOR UNIT Performance T est Condition ISO5151 C O O L I N G Capacity kW 2.50 (0.80 ~ 3.00) kcal/h 2150 (690 ~ 2580) BTU/h 8500 (2700 ~ 10200) EER W/W 4.39 (4.57 ~ 3.85) kcal/hW 3.
5 1. Cooling capacities are based on indoor tempera ture of 27 ° C Dry Bulb (80.6 ° F Dry Bulb), 19.0 ° C Wet Bulb (66.2 ° F W et Bulb) and outdoor air temperature of 35 ° C Dry Bulb (95 ° F Dry Bulb), 24 ° C W et Bulb (75.
6 2.2. CS-E12GFEW -2 CU-E12GFE-2 ITEM UNIT INDOOR UNIT OUTDOOR UNIT Performance T est Condition ISO5151 C O O L I N G Capacity kW 3.50 (0.80 ~ 3.80) kcal/h 3010 (690 ~ 3270) BTU/h 1 1900 (2700 ~ 13000) EER W/W 3.63 (4.32 ~ 3.33) kcal/hW 3.12 (3.73 ~ 2.
7 1. Cooling capacities are based on indoor tempera ture of 27 ° C Dry Bulb (80.6 ° F Dry Bulb), 19.0 ° C Wet Bulb (66.2 ° F W et Bulb) and outdoor air temperature of 35 ° C Dry Bulb (95 ° F Dry Bulb), 24 ° C W et Bulb (75.
8 2.3. CS-E18GFEW -2 CU-E18GFE-2 ITEM UNIT INDOOR UNIT OUTDOOR UNIT Performance T est Condition ISO5151 C O O L I N G Capacity kW 5.00 (0.90 ~ 5.60) BTU/h 17100 (3100 ~ 19100) kcal/h 4300 (770 ~ 4820) EER W/W 3.23 (3.53 ~ 2.93) kcal/hW 2.77 (3.02 ~ 2.
9 1. Cooling capacities are based on indoor tempera ture of 27 ° C Dry Bulb (80.6 ° F Dry Bulb), 19.0 ° C Wet Bulb (66.2 ° F W et Bulb) and outdoor air temperature of 35 ° C Dry Bulb (95 ° F Dry Bulb), 24 ° C W et Bulb (75.
10 3 Location of Controls and Component s 3.1. Indoor Unit 3.2. Out door Unit 3.3. Remote Control.
11 4 Dimensions 4.1. Out door Unit 4.1.1. CU-E9GFE-2 CU-E12GFE-2.
12 4.1.2. CU-E18GFE-2.
13 5 Refrigeration Cycle Diagram 5.1. CS-E9GFEW -2 CU-E9GFE-2 CS-E12GFEW -2 CU-E12GFE-2 If piping length is over rated length , ad ditional refrigerant should be added as shown in the table. Model Piping size Rated Length (m) Max. Elevation (m) Min. Piping Length (m) Max.
14 5.2. CS-E18GFEW -2 CU-E18GFE-2 If piping length is over rated length, additional refrigerant should be added as shown in the table. Model Piping size Rated Length (m) Max. Elevation (m) Min. Piping Length (m) Max. Piping Length (m) Additional Refrigerant (g/m) Gas Liquid E18GFE-1 1/2” 1/4” 7.
15 6 Wiring Connection Diagram 6.1. Out door Unit 6.1.1. CU-E9GFE-2 CU-E12GFE-2.
16 6.1.2. CU-E18GFE-2.
17 7 Electronic Circuit Diagram 7.1. Out door Unit 7.1.1. CU-E9GFE-2 CU-E12GFE-2.
18 7.1.2. CU-E18GFE-2.
19 7.1.3. Main Printed Circuit Board CU-E9GFE-2 CU-E12GFE-2.
20 7.1.4. Main Printed Circuit Board CU-E18GFE-2.
21 8 Disassembly and Assembly Instructions 8.1. Out door Unit 8.1.1. CU-E9GFE-2 CU-E12GFE-2 1. Remove the 3 screws of the T op Panel. Fig. 13 2. Remove the 6 screws of the Front Panel. Fig. 14 3. Remove the screw of the T erminal Board Cover . 4. Remove the T op Cover of the Control Board by 4 hooks.
22 8.1.2. CU-E18GFE-2 1. Remove the 4 screws of the T op Panel . Fig. 19 2. Remove the 10 scre ws of the Front Panel. Fig. 20 3. Remove the T op Cover of the Ele ctronic Controller . Fig. 21 4. Remove the Control Board. Fig. 22 5. Remove the 8 screws of the Electronic Controller .
23 9 T echnical Dat a 9.1. Operation Characteristics CS-E9GFEW-2 CU-E9GFE-2.
24.
25.
26.
27 CS-E12GFEW -2 CU-E12GFE-2.
28.
29.
30.
31 CS-E18GFEW -2 CU-E18GFE-2.
32.
33.
34.
35 9.2. Sensible Cap acity Chart O CS-E9GFEW -2 CU-E9GFE-2 O CS-E12GFEW-2 CU-E12GFE-2 O CS-E18GFEW-2 CU-E18GFE-2 220V Outdoor T emp. ( ° C) 230V 30 ° C3 5 ° C4 0 ° C4 6 ° C 240V TC SHC IP TC SHC IP TC SHC IP TC SHC IP D.B. W .B. kW kW kW kW kW kW kW kW kW kW kW kW 27 17.
36 10 Exploded V iew and Replacement Part s List 10.1. Indoor Unit.
37 REF . NO. P ART NAME AND DESCRIPTION QTY . C S-E9GFEW-2 CS-E12GFEW-2 CS-E18GFEW-2 REMARKS B1 EV APORA TOR ASS'Y 1 CW1786554 ← CW1800652 B1-7 FLARE NUT 1 CW1723546 ←← B2 FITTING SPRING / .
38 (Note) • All parts are supplied from ACBU, Japan. • "O" marked parts are recommended to be kept in stock. F10 CASING (LEFT ) 1 CW1768075 ←← F1 1 FIXTU RE, REF .
39 10.2. CU-E9GFE-2 CU-E12GFE-2 Note: The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not k ept as standard service part s.
40 (Note) • All parts are supplied from PHAAM, Malaysia (V endor Code: 061). • "O" maked parts are recommended to be kep t in stock. REF .
41 10.3. CU-E18GFE-2 Note: The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not k ept as standard service part s.
42 (Note) • All parts are supplied from PHAAM, Malaysia (V endor Code: 061). • "O" maked parts are recommended to be kep t in stock. [PHAAM] Printed in Malaysia SFSC0804-00 REF .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Panasonic CS-E9GFEW-2 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Panasonic CS-E9GFEW-2 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Panasonic CS-E9GFEW-2 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Panasonic CS-E9GFEW-2 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Panasonic CS-E9GFEW-2, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Panasonic CS-E9GFEW-2.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Panasonic CS-E9GFEW-2. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Panasonic CS-E9GFEW-2 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.