OBX -IC2024S -120/60 O wner ’ s Manual Installation and Operation Rugged Water Resistan t Inverter / Charger.
OutBack Po wer S yst ems OutBack Po wer Sy stems is a leader in advanced ener gy conv ersion technology . Our products include true sine wave in ver ter/chargers, maximum po wer point charge c ontrollers , system communica tion components, as w ell as breaker panels , breakers , accessories, and assembled sy stems.
1 T ABLE OF C ONTENTS Welcome to the OutBack Extreme Rugged Water Resistant Inverter/Charger ............................................ 2 P arts I ncluded...............................................................................................
2 W elcome to the OutBack Extreme Rugged W ater Resistant Inv er ter/Char ger The OutBack Extreme Rugged Water Resistant Inverter/Charger (hereafter called the Inverter) provides 120 Vac, 60 Hz, true-sine wave power, from a 24 Vdc battery source. It is designed for rugged operational environments in an unprotected, uncontrolled climate.
3 P ar ts Included Standard with the OutBack Extreme Rugged Wat er Resistant Inverter/Charger , Model OBX-IC2024S-120/60 : • OneOwner ’ sManual • OneDCCov er(DCC) • One.
4 R EA D F IR S T ! SA VE THESE INSTRUCTIONS Read all instructions and cautionary markings on the Inverter, the batteries and all appropriate sections of this installation and user manual as well as other component manuals before using the system. Be cautious around electricity, electrical components, and batteries.
5 Designthebatteryenclosuretopreventaccumulationandconcentrationofhydrogengasin“pockets”at the top of the enclosure. Vent the battery compartment from the highest point to the outside. A sloped lid can also be used to direct the ow of hydrogen to the vent opening.
6 MOUNTING TheInverterweighs57.5lbs(26.08kg)andmustbesecuredwithappr opriatefastenerstoastur dy • mounting sur face capable of supporting its weight. Depending on application, it may be easier for two people to install the unit due to the Inv er ter’ s weight.
7 The equipment ground on each is marked with this symbol: Box lug for grounding the Inverter chassis SY STEM PRO TEC TION Electrical systems are designed to protect you, the wires, the components, and the devices served by the system. Each Inverter must be par t of a permanently grounded electrical system (see below).
8 WIRE C ONNEC TIONS DC Wiring TheInverterusesDCbrassbatteryterminalswith8Mx1.00stainlesssteelthreadedstuds.Youcanaccess the terminals by removing the four screws that attach the DC cover plate, and pulling it o.
9 12 V/200 amp-hours - 12 V/200 amp-hours - 12 V/200 amp-hours - V oltage remains at 12 V 200 Ah + 200 Ah + 200 Ah + 200 Ah = 800 Ah 12 V/200 amp-hours 12 V/200 amp-hours 12 V/200 amp-hours 12 V/200 amp-hours 12 V + 12 V + 12 V + 12 V = 48 V Amp-hours remain at 200 T wostringsofbatteriesinseriesareconnectedinparallel.
10 6 V Batter y Wiring Examples f or a 24-volt system - DC DISCONNECT (FUSE OR CIRCUIT BREAKER) - - - - SERIES: 200 amp-hours - - DC DISCONNECT (FUSE OR CIRCUIT BREAKER) - - - - - - - SERIES STRING 1 .
11 12 V Batter y Wiring Examples f or a 24-volt system - DC DISCONNECT (FUSE OR CIRCUIT BREAKER) - - SERIES: 200 amp-hours - - - - SERIES STRING 1 CONNECTS TO INVERTER’S POSITIVE TERMINAL DC DISCONN.
12 A C Wiring A C OUT SOCKET • — Maxicon circular molded watertight connector supplies power to the loads using the pr ovided A C cable and plug. A C IN SOCKET • — Maxicon circular molded watertight connector supplies incoming AC from the grid or a generat or to the Inverter .
13 Follow these steps to wire the Inverter to your system: Open all DC breakers or remove any fuses before connecting wiring. 1. Open all AC breakers or remove any fuses before connecting wiring. 2. With all power o, connect the AC IN Maxicon plug wires to the AC source.
14 POWERING UP Once all connections are established, it is safe to turn the power on, in the following order: Connect DC power , by closing the DC breaker or c onnecting the fuse. The MA TE will pow er up . • The Inv erter will energize and begin delivering 120 v olts to the output immediately .
15 THE MA TE2 SYSTEM C ONTROLLER AND DISPLA Y The MATE serves several functions: Allows y ou to monitor the Inverter through a series of con venient display scr eens. These display • the status messages, and allow y ou to take both DC (voltage) and A C (voltage and current) meter readings .
16 < OFF > —turns o all Inverters connected to the MATE < SRCH > —the Inverter begins search mode if the AC load connected is smaller than allowed by the programming of the search function. This function is not normally required to be used with the OBX-IC2024S-120/60 Inverter.
17 The AC INPUT C ONTROL screen is called up, allowing the user • to connect or disconnect the Inverter to an AC input source . AC INPUT CONTROL currently: USE DROP USE OK < USE > enables the Inverter to connect to an AC input source.
18 PRESS THREE TIMES: The CHARGER CONTROL scr een appears. This allows the • operation of the Inverter ’ s battery charger to be preset f or an available A C source . CHARGER CONTROL currently: AUTO OFF AUT O ON OK < OFF > disables all charger functions in the Inverter.
19 MAIN-------------------------------- 12:00:30P SUM ST A TUS SETUP ADV The user can press the <SUM> soft key to display the Summary screen. FX T otal 25.
20 SETUP SCREENS The Setup screens allow you to change several settings, to make your system run more smoothly. You can program the amperage size of the AC source, to keep the Inverter from overdrawing a generator. You can program the Summary screen to pop up automatically like a computer screensaver.
21 SETUP/MA TE/SUMMARY --------- summary control BACK T YPE DELA Y ROLL MAIN-------------------------------- 12:00:30P SUM ST A TUS SETUP ADV SETUP/MA TE/PAGE1-------------- mate code rev 4.
22 SETUP/MA TE/SUMMARY ---------- summary control BACK T YPE DELA Y ROLL After selecting FX Only and exiting the SETUP/MATE/SUM/ TYPE screen, the SUMMARY screen will automatically appear whenever the MATE has been inactive for the < DELAY > set point (very much like a screensaver on a computer monitor).
23 SETUP/MA TE/SUMMARY/T YPE-- sum screen 19 minutes delay time BACK INC DEC SETUP/MA TE/PAGE2-------------- choose category: PG1 SUMRY COM MAIN SETUP/MA TE/SUMMARY ---------- summary control BACK T Y.
24 •< REPOLL >forcestheMATEto“rediscover”alltheOutBack devices it is connected to. This must be used any time an OutBack device is moved or added to a HUB. •< PC > and < DEBUG > are not normally used with the OBX-IC2024S-120/60 Inverter.
25 Press < STATUS > on the Main menu to access the STATUS menu. STATUS contains all the meters and mode displays for OutBack products connected to the MATE. The STATUS menu is divided rst by product and then into menu categories, such as meter, modes, and statuses.
26 ST A TUS/FX/PAGE1--------------- choose category MODES METER BA T T PG2 ST A TUS/FX/PAGE2--------------- choose category PG1 ERROR WARN PG3 ST A TUS/FX/PAGE3--------------- choose category PG2 DISC.
27 METER Screens The METER screens displays current, voltage and wattage measurements, Inverter status, and the version of Inverter software, in this order: initial screen, beginning with • charg.
28 ST A TUS/FX/MODE-------------P00 battery 27 .8 vdc actual DOWN ST A TUS PORT ST A TUS/FX/METER-------------P00 absorb 28.8 vdc setpoint DOWN UP TOP PORT ST A TUS/FX/MODE-------------P00 battery 27 .8 vdc temp compensated DOWN UP TOP PORT ST A TUS/FX/BA T T ---------------P00 absorb 00.
29 ST A TUS/FX/PAGE2------------------- choose category: PG1 ERROR W ARN PG3 ERROR Screens Allscreensreadstatusas“No”undernormalconditions.Iftheunitshutsoduetoaspeciederrorcondition,that screenwillchangeto“Yes”.
30 ST A TUS/FX/WARN-------------P00 acin freq No too low DOWN UP T OP PORT ST A TUS/FX/WARN-------------P00 acin freq No too high DOWN ST A TUS PORT ST A TUS/FX/WARN--------------P00 acin voltage No t.
31 ST A TUS/FX/DISCON-----------P00 acin freq No too high DOWN ST A TUS PORT ST A TUS/FX/DISCON-----------P00 acin voltage No > max DOWN UP T OP PORT ST A TUS/FX/DISCON----------P00 acin freq No to.
32 INST ALLA TION DRA WING A 30A input breaker (maximum) must be • used with the AC sourc e A 30A breaker (maximum) must be used to • protect the output circuit A single Inverter can continuously power • up to 2.0 kW of loads depending on the ambient temperatur e.
33 INST ALLA TION CHECK LIST ITEM YES NO Manual read and reviewed? System mount ed with the recommended number and siz ed fasteners? System installed ac cording to r equired codes and r egulations? Sy.
34 OBX -IC2024S-120/60 Inverter/Charger Specications Nominal DC Input Voltage Range 24 Vdc Nominal AC Voltage / Frequency 120 Vac / 60 Hz ContinuousPowerRatingat25°CAmbient 2000 VA ContinuousACRMSOutputat25°C 16.
35 AC Input Operating Voltage Range Note : This is the rec ommended AC input voltage r ange to be supplied to the Inver ter . V oltages outside of this range will not be accepted b y the Inverter.
36 INVERTER DEF A UL T V AL UES (subjec t to change with upgrades) 24 VDC System DEFAULT MINIMUM MAXIMUM Float Voltage 27.4Vdc 24 Vdc 30 Vdc Absorb Voltage 29.4Vdc 26 Vdc 32 Vdc EQ Voltage 28.8V 28Vdc 34 Vdc ReFloat 25Vdc 22 Vdc 26 Vdc LBCO 21 Vdc 18Vdc 24 Vdc Absorb Time 2.
37 Maintenance F ollowing exposure t o salt water , rinse all exposed surfaces to prevent corr osion. Recoat the DC lugs • and other exposed conductors with dielectric grease. P eriodically check that the battery cable lugs are tight and secure accor ding to the recommended • torquesettingsonpage8.
38 1- Y ear Limited W arranty OutBack Extreme Inverter/Chargers OutBackPowerSystems,Inc.(“OutBack”)providesaoneyear(1)limitedwarranty(“Warranty”)against.
39 After receiving the RMA number, pack the Product(s) authorized for return, along with a copy of the original purchase invoice and warranty certicate, in the original Product shipping container(s) or packaging providing equivalent protection and mark the outside clearly with the RMA number.
40 OUTBA CK EX TREME INVERTER/CHARGER LIMITED W ARRANTY REGISTR A TION Complete this form and return it to: OutBack P ower Systems Inc. 19009 62nd Ave .
41.
Corpora te Headquarters 1900962ndAv enueNE Arlington, W A98223USA Phone:(+1)360.435.6030 www.outbackpower .com 900-0046-01-00REVA European Sales Oce Barcelona, España Phone:+34.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Outback Power Systems OBX-IC2024S-120/60 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Outback Power Systems OBX-IC2024S-120/60 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Outback Power Systems OBX-IC2024S-120/60 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Outback Power Systems OBX-IC2024S-120/60 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Outback Power Systems OBX-IC2024S-120/60, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Outback Power Systems OBX-IC2024S-120/60.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Outback Power Systems OBX-IC2024S-120/60. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Outback Power Systems OBX-IC2024S-120/60 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.