Manuale d’uso / di manutenzione del prodotto 9005 del fabbricante Orion
Vai alla pagina of 16
IN 155 Rev . B 02/09 Providing Exceptional Consumer Optical Products Since 1975 Customer Support (800 ) 676-1343 E-mail: support@telescope.com Corporate Offices (831) 763-7000 89 Hangar Way , Watsonvi.
2 T ube rings Objectiv e lens cell Dew cap/lens shade Declination loc k le ver Large counterweight Small counterweight Counterweight lock knobs Counterweight shaft “T oe sa ver” T ripod leg Access.
3 1. Par ts List Qty . Description 1 Optical tube assembly 1 German-type equatorial mount 1 Large counterw eight 1 Small counterw eight 1 Counterweight shaft 3 T r ipod Legs with mounting hardware 1 A.
4 2. Assembly Car efully open all of the bo x es in th e shipp ing con taine r . Mak e sur e all the par ts listed in Secti on 1 are pr esent . Sa ve the bo x es and pack aging material . In th e unlik ely ev ent tha t you need to return the telescope , y ou m ust use the or iginal packag - ing.
on the worm gear shaft. Then tighten the scre w . 12. T o place the finder scope in the finder scope br acket (Figure 3), first unthread the two blac k nylon thumbscrews until the screw ends are flush with the inside diameter of the bracket.
6 3. Balancing the T elescope T o ensure smooth mov ement of the telescope on both axes of the equator ial mount, it is imperative that the optical tube is properly balanced. We will first balance the telescope with respect to the R.A. axis, then the Dec.
The telescope is now balanced on both axes . Now when you loosen the loc k lev er on one or both ax es and manually point the telescope, it should move without resistance and should not drift from where you point it.
T o find P olar is in the sky , look nor th and locate the pattern of the Big Dipper (Figure 7). The two stars at the end of the “bowl” of the Big Dipper point r ight to P olaris. Obser v ers in the Southern Hemisphere aren’t so f or tunate to hav e a bright star so near the south celestial pole (SCP).
9 that is cast into the mount (located directly below the large thumbscrew; see Figure 3). Retighten the thumbscrew . 2. Rotate the date circle until the “0” line on the meridian offset scale lines up with the time meridian indicator mark.
10 loosen the big tripod attachment knob directly under neath the base of the equatorial mount. The fine adjustment knobs work b y loosening one and then tightening the other . When done, retighten the tr ipod attachment knob to fir mly secure the mount and tripod.
11 c. d. Figure 9. This illustration shows the telescope pointed in the f our cardinal directions: (a) nor th, (b) south, (c) east, (d) west. Note that the tripod and mount ha ve not been moved; only the telescope tube has been moved on the R.A. and Dec.
Cooling the T elescope All optical instr uments need time to reach “ther mal equilibr i- um. ” The bigger the instr ument and the larger the temperature change, the more time is needed. Allo w at least a half-hour f or your telescope to cool to the temper ature outdoors.
13 lence causes objects viewed through the telescope to “boil. ” If the stars are twin kling noticeab ly when you look up at the sky with just y our e yes , the seeing is bad and y ou w ill be limited to vie wing with low powers (bad seei ng aff ects images at high pow ers more sev erely).
C. The Planets The planets don’t sta y put like the stars (the y don’t hav e fixed R.A. and Dec. coordinates), so you’ll hav e to ref er to char ts published monthly at our website, www .telescope.com, or in monthly magazines like Astronomy , Sky & T elescope , to locate them.
15 used or the image will be blurred beyond recognition. T r y expo - su re tim es bet w ee n 1 an d 10 sec on ds , d epe nd in g up on the brightness of the planet to be photographed and the ISO of the film being used.
Orion T elescopes & Binoculars 89 Hangar Way , Watsonville, CA 95076 Customer Support Help Line (800) 676-1343 • Day or Evening One-Y ear Limited W arranty This Orion AstroView 120ST Equatorial refractor is warr anted against def ects in materials or workman- ship for a period of one y ear from the date of purchase.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Orion 9005 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Orion 9005 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Orion 9005 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Orion 9005 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Orion 9005, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Orion 9005.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Orion 9005. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Orion 9005 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.