Manuale d’uso / di manutenzione del prodotto Metal Weather Station BAR908HG del fabbricante Oregon Scientific
Vai alla pagina of 21
EN 1 CONTENTS Product Overvi ew .......................................................... 3 Front View ..................................................................... 3 Back View .................................................................
EN 2 Specifications ................................................................ 18 About Oregon Scientific ............................................... 20 EU-Declaration of Conformity ..................................... 20 FCC Statement ..
EN 3 1. Weather Forecast Area: Animated weather forecast 2. Temperature / Humidity / Comfort Zone Area: Readings and trend lines; comfort zone; sensor channel number 3. UVI / Barometer Area: UV level and barometric pressure bar chart; UV Index and barometric readings 4.
EN 4 1. ALARM: View alarm status; set alarm 2. SELECT: Switch Areas 3. UP: Increase setting / activate radio-controlled clock 4. CHANNEL: Switch remote sensor display 5. MODE: Change settings / display 6. HISTORY: View historical barometer and UV readings 7.
EN 5 Weather Forecast Area 1. Low battery icon for main unit 2. Weather display T emperature / Humidity / Comfort Zone Area 1. Selected Area icon 2. Heat Index 3. Indoor / Outdoor channel number (IN, 1-5) / reception status 4. Low battery icon for remote sensor 5.
EN 6 UVI / Barometer Area 1. Barometric pressure is showing 2. UV is showing 3. Low battery icon for UV sensor 4. UVI value is showing 5. UV exposure time countdown has started 6. UV index level 7. UV exposure time for user 8. Barometer / UV chart 9. SPF applied to user for UV exposure 10.
EN 7 REMOTE SENSOR RTGN318 / RTGN318D 1. RESET 2. EU / UK radio signal format switch (RTGN318D only) 3. Double sided adhesive tape 4. CHANNEL switch (1-5) 5.
EN 8 RTGN318A 1 3 2 4 5 1. RESET 2. Double sided adhesive tape 3. CHANNEL switch (1-5) 4. Wall mount 5. Battery compartment.
EN 9 GETTING STARTED BATTERIES Batteries are supplied with this product: • Main unit 3 x UM-4 (AAA) 1.5V • Remote unit 1 x UM-3 (AA) 1.5V Insert batteries before first use, matching the polarity as shown in the battery compartment. For best results, install batteries in the remote sensor before the main unit.
EN 10 2. Insert the batteries. 3. Set the channel and radio signal format (RTGN318D only). The switches are located in the battery compartment. SWITCH OPTION Channel If you are using more than one sensor , select a different channel for each sensor . Radio Signal Format EU (DCF) / UK (MSF) (RTGN318D only) 4.
EN 1 1 next to the Area. Then, simultaneously press and hold MEM and CHANNEL for 2 seconds. NOTE If the sensor is still not found, check the batteries. CLOCK AND CALENDAR This product tracks the time and date based on radio- controlled signals from the RTGN318 / RTGN318D / RTGN318A remote sensor , or manual settings that you enter .
EN 12 TURN RADIO-CONTROLLED CLOCK ON / OFF If you wish to manually set the clock, you must first disable the radio-controlled feature. T o do this, navigate to the Clock / Alarm Area. Then, press and hold DOWN on the main unit for 2 seconds. T o enable it, navigate to the Clock / Alarm Area, then press and hold UP for 2 seconds.
EN 13 4. Select the hour and minute. Press UP or DOWN to change settings. 5. Press ALARM to confirm. 6. The Daily Alarm icon will appear when the alarm is set. SET PRE-ALARM The Pre-Alarm can be set to sound 15, 30, 45, or 60 minutes before the Daily Alarm.
EN 14 SELECT MEASUREMENT UNIT Slide the mb / inHg switch (in the clock battery compartment), to change the display unit. VIEW BAROMETER HISTORY Navigate to the Barometer Area. Then press HISTOR Y repeatedly to scroll through the measurements. The number shown in the HR box indicates how long ago each measurement was taken (e.
EN 15 NOTE The night time icon displays from 6 PM to 6 AM. Whe n th e C han nel 1 se nso r r eco rds a te mpe rat ure of 2°C (35.6°F) or lower , the RAINY icon becomes SNOWY . UV MEASUREMENT The UVR128 Ultra-Violet Radiation Sensor is available as an optional item for BAR908HG / BAR908HGU / BAR908HGA.
EN 16 MAXIMUM / MINIMUM MEMOR Y FOR UVI T o view the maximum and minimum memory for UVI: 1. Press SELECT to navigate to the Barometer Area. 2. Press MODE to select the UV display. 3. Press MEM to show maximum, minimum and current UVI readings. 4. Press and hold MEM for 2 seconds to clear the UVI memory.
EN 17 COMFORT ZONE The Comfort Zone indicates how comfortable the climate is, based on current temperature and humidity measurements. ZONE TEMPERA TURE HUMIDITY WET Any >70% COM 20-25°C (68-77°F) 40-70% DR Y Any <40% NOTE This information is shown in the Humidity Area when the current measurement is displayed.
EN 18 separately for special treatment and not as normal household waste. • Placement of this product on certain types of wood may result in damage to its finish for which Oregon Scientific will not be responsible. Consult the furniture manufacturer’s care instructions for information.
EN 19 (4 .6 1 x 3 .1 5 x 6. 73 i n) Weight 80 g (2.82 oz) without battery T emperature Unit °C or °F Indoor Range -5 °C to 50 °C (23 °F to 122 °F) Outdoor Range -20 °C to 60 °C (-4 °F to 140 °F) Resolution 0.
EN 20 Batteries 3 x UM-4 (AAA) 1.5V Thermo / Hygro Remote Unit Batteries 1 x UM-3 (AA) 1.5V NOTE It is recommended that you use alkaline batteries with this product for longer performance. ABOUT OREGON SCIENTIFIC Visit our website (www .oregonscientific.
EN 21 This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However , there is no guarantee that interference will not occur in a particular installation.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Oregon Scientific Metal Weather Station BAR908HG è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Oregon Scientific Metal Weather Station BAR908HG - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Oregon Scientific Metal Weather Station BAR908HG imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Oregon Scientific Metal Weather Station BAR908HG ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Oregon Scientific Metal Weather Station BAR908HG, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Oregon Scientific Metal Weather Station BAR908HG.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Oregon Scientific Metal Weather Station BAR908HG. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Oregon Scientific Metal Weather Station BAR908HG insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.