Manuale d’uso / di manutenzione del prodotto SunDual 10GbE XFP del fabbricante Oracle Audio Technologies
Vai alla pagina of 86
Sun Dual 10GbE XFP PCI Express Card User’ s Guide P ar t No . 820-0184-14 May 2010, Re vision A.
Please Recycle Copyright © 2009, 2010, Oracle and/or its affiliates. All rights reserved. This software and related documentation ar e provided under a license agr eement containing restrictions on use and disclosure and ar e protected by intellectual property laws.
iii Contents Using This Documentation vii 1. Product Overview 1 Components 1 Product Description 1 Hardware and Software Requirements 3 Features 3 Declaration of Conformity 5 2.
iv Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 Verifying the Hardware Installation 20 ▼ T o V erify the Hardwar e Installation 20 Rebooting the System 22 4.
Contents v Setting Parameters on a Linux Platform 44 ▼ T o Set Parameters Using the ethtool Utility 44 ▼ T o Set Parameters Using the Bundled configtool Utility 48 T uning for Maximum Performance on a Linux Platform 49 6.
vi Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 A. Specif ications 67 Connectors 67 Performance Specifications 68 Physical Characteristics 69 Power Requirements 69 B.
vii Using This Documentation This guide provides instructions for installing both the har dware and software for the Sun Dual 10GbE XFP PCI Express car d from Oracle. This manual also describes how to configur e the nxge driver , which controls the card.
viii Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 Shell Pr ompts Shell Prompt C shell machine-name % C shell superuser machine-name # Bourne shell and Korn shell $ Bourne shell and .
Using This Documentation ix Related Documentation The documents listed as online are available at: http://docs.sun.com/app/docs/prod/dual.xfpsr2.pci Documentation, Support, and T raining These web sites provide additional r esources: Documentation Feedback Submit comments about this document by clicking the Feedback[+] link at http://docs.
x Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010.
1 CHAPTER 1 Pr oduct Overview This chapter provides an overview of the Sun x8 Expr ess Dual 10 Gigabit Ethernet Fiber XFP Low Prof ile Adapter, including: ■ “Components” on page 1 ■ “Product.
2 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 FIGURE 1- 1 shows the adapter . FIGURE 1-1 Sun x8 Express Dual 10 Gigabit Ethernet Fiber XFP Low Pr ofile Adapter Har dware and Softwar e Requir ements Before installing the adapter , make sure your system meets the hardwar e and software r equirements.
Chapter 1 Product Overview 3 Featur es The Sun x8 Express Dual 10 Gigabit Ethernet Fiber XFP Low Pr ofile Adapter provides the following features: ■ T wo full-duplex 10 gigabit Ethernet interface that use a 10 gigabit Ethernet small form factor pluggable (XFP), optical transceiver with duplex LC fiber connector ■ IEEE 802.
4 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 Declaration of Conformity EMC USA—FCC Class A This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This equipment may not cause harmful interference.
Chapter 1 Product Overview 5 /S/ /S/ Dennis P . Symanski DA TE W orldwide Compliance Engineering Sun Microsystems, Inc. 4150 Network Circle, MPK15-102 Santa Clara, CA 95054 U.S.A. T el: 650-786-3255 Fax: 650-786-3723 Donald Cameron DA TE Program Manager/Customer Quality Sun Microsystems Scotland, Limited Blackness Road, Phase I, Main Bldg.
6 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010.
7 CHAPTER 2 Installing and Setting Up the Driver This chapter explains how to download and install the nxge driver . The nxge gigabit Ethernet driver ( nxge (7D)) is a multi-threaded, loadable, clonable, GLD-based STREAMS driver .
8 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 2. Uncompress the gzipped tar f ile: 3. Unpack the tar f ile: a. For SP ARC systems, change to the following directory: b. For x86 systems: 4. For SP ARC systems, determine which architecture your system is running: a.
Chapter 2 Installing and Setting Up the Driver 9 6. Select the packages you want to install: ■ Press Return or type all to accept the default and install all packages. ■ T ype the specific numbers, separated by a space, if you pr efer not to install any optional packages.
10 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 Downloading and Installing the Driver on a Linux Platform 1. Login to your system. 2. Download the driver RPM for your operating system: http://www.sun.com/download/products.xml?id=44eb1efd For example: 3.
Chapter 2 Installing and Setting Up the Driver 11 Note – In RHEL5.0 and later releases, the driver is packaged in the kmod driver binary package format. This packaging allows forward and backward driver binary compatibility within the same flavors of RHEL5 releases.
12 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 7. Use the ethtool command to check the parameter conf igurations that apply to the nxge driver . ▼ T o Remove the Driver Fr om a Linux Platform ● T o remove the driver packages from a Linux Platform use the rpm -e command: (For 10G) # ethtool -i eth4 driver: nxge version: 2.
13 CHAPTER 3 Installing the Adapter This chapter describes how to install the Sun x8 Express Dual 10 Gigabit Ethernet Fiber XFP Low Prof ile Adapter in your system and verify that it has been installed correctly .
14 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 Caution – Sun x8 Express Dual 10 Gigabit Ethernet Fiber XFP Low Profile Adapter mechanical fit limitations: Do not install the Sun x8 Express Dual 10 Gigabit Ethernet Fiber XFP Low Pr ofile Adapter in slot-2 of a Sun Fire T2000 system.
Chapter 3 Installing the Adapter 15 Note – These illustrations show the Sun x8 Express Dual 10 Gigabit Ethernet Fiber XFP Low Prof ile Adapter being installed into a Sun Fire T2000, which requir es a standard height bracket for the low prof ile adapter .
16 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 9. Secure the retaining clip Caution – Do not use excessive force when installing the adapter into the PCI-E slot.
Chapter 3 Installing the Adapter 17 1 1. Install the optical transceivers. Note – Illustrations for installing the adapter and installing the optical transceiver show differ ent systems. This difference in systems pr ovides the maximum clarity for installing the optical transceiver and shows the most complicated adapter installation.
18 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 ▼ T o Install an Optical T ransceiver 1. Pull the white locking handle into the full horizontal position.
Chapter 3 Installing the Adapter 19 4. Push the handle closed to lock the optical transceiver in place. 5. Repeat Step 1 through Step 4 to install the second optical transceiver 6.
20 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 7. Connect the Ethernet cables. V erifying the Har dware Installation After you have installed the Sun 10-Gigabit Ethernet adapter , but before you boot your system, perform the following tasks to verify the installation.
Chapter 3 Installing the Adapter 21 3. V iew the device that you installed. Using the previous example, type: 4. Use the .properties command to display a list of device properties. The . properties command displays the specific information about the device.
22 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 5. T ype the following when you f inish looking at the .properties values: Rebooting the System After verifying the adapter installation, use the boot -r command to perform a reconf iguration boot on your system.
23 CHAPTER 4 Network Conf iguration This chapter describes how to edit the network host files after the adapter has been installed on your system. This chapter contains the following sections: ■ “.
24 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 1. At the command line, use the grep command to search the /etc/path_to_inst f ile for nxge interfaces. In this example, the device instance is from a Sun x8 Expr ess Dual 10 Gigabit Ethernet Fiber XFP Low Prof ile Adapter installed in slot 1.
Chapter 4 Network Configuration 25 ■ The host name must be differ ent from any other host name of any other interface, for example: /etc/hostname.nxge0 and /etc/hostname.nxge1 cannot share the same host name. The following example shows the /etc/hostname.
26 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 ▼ T o Set Up a 10-Gigabit Ethernet Port on a Diskless Client 1. Locate the root directory of the diskless client on the host server .
Chapter 4 Network Configuration 27 Installing the Solaris Operating System Over a 10-Gigabit Ethernet Network The Solaris Advanced Installation Guide describes the full procedure for installing the Solaris Operating System over the network.
28 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 2. Find the root directory of the client system. The client system’s root dir ectory can be found in the install server ’s /etc/bootparams file. Use the grep command to sear ch this file for the r oot directory .
Chapter 4 Network Configuration 29 5. Shut down and halt the client system. Use the shutdown command to go to the OpenBoot ( ok ) prompt. 6. At the ok prompt, use the show-nets command to f ind the device path of the 10-Gigabit Ethernet device. The show-nets command lists the system devices.
30 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 ■ If the software is installed, the pr evious command will return the package name you typed in. In that case, skip to Step 10 . ■ If the software is not installed, install the software fr om the download center .
Chapter 4 Network Configuration 31 4. Plug the Ethernet cable to the adapter port. 5. Power on the system. 6. Press the F2 key or the Control/E keys to go to the BIOS. 7. Check and make sure that the boot order of Hard Drive is higher than network devices.
32 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 10. Press the F12 key to install the OS from the network. If the cable is connected to the right port, you should see the MAC address that you assigned to your PXE server displayed by BIOS.
33 CHAPTER 5 Conf iguring the nxge Device Driver Parameters The nxge device driver controls the Sun x8 Express Dual 10 Gigabit Ethernet interfaces. Y ou can manually set the nxge driver parameters to customize each device in your system. This chapter lists the available device driver parameters and describes how you can set these parameters.
34 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 processing. The Sun 10-Gigabit Ethernet Adapter utilizes Sun’s own innovative MAC Controller to map the 10-Gigabit XAUI interface onto the PCI Express form factor . It supports 10 Gb/sec bandwidth using eight transmit and eight receive lanes.
Chapter 5 Configuring the nxge Device Driver P arameters 35 ▼ T o Specify Device Instances for the ndd Utility Before you use the ndd utility to get or set a parameter for a nxge device, you must specify the device instance for the utility . 1. Check the /etc/path_to_inst f ile to identify the instance associated with a particular device.
36 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 After you enter the parameter name, the ndd utility prompts you for the parameter value. 2. T o list all the parameters supported by the nxge driver , type ? . Setting Parameters Using the nxge.
Chapter 5 Configuring the nxge Device Driver P arameters 37 ▼ T o Set Driver Parameters Using an nxge.conf File 1. Obtain the hardware path names for the nxge devices in the device tree. a. Check the /etc/driver_aliases f ile to identify the name associated with a particular device: b.
38 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 # 10 gigabit related parameters ( i.e adv_10gfdx_cap) # apply only to 10gigabit ports. # Half duplex is not supported on any NIU card. # # adv-autoneg-cap # Advertise auto-negotiation capability.
Chapter 5 Configuring the nxge Device Driver P arameters 39 # # #------- Receive DMA Configuration ---------------------------- # # rxdma-intr-time # Interrupts after this number of NIU hardware ticks have # elapsed since the last packet was received.
40 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 b. The following parameters operate on a per port basis and can be set using the /platform/sun4u/kernel/drv/nxge.
Chapter 5 Configuring the nxge Device Driver P arameters 41 d. The following example shows ports on two different cards being set. Only one node needs to be specif ied.
42 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 3. Add the following to a startup script, or use ndd before plumbing the interface: Utilizing more soft-rings provided by the Solaris TCP/IP stack signif icantly improves bulk thr oughput for Rx.
Chapter 5 Configuring the nxge Device Driver P arameters 43 ▼ T o Obtain Higher Thr oughput Using the Generic T unables for the Solaris TCP/IP Stack ● T o obtain higher throughput, add the followi.
44 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 Setting Parameters on a Linux Platform ▼ T o Set Parameters Using the ethtool Utility 1. Determine which parameters are available using the ethtool utility: # ethtool -help eth4 ethtool version 1.
Chapter 5 Configuring the nxge Device Driver P arameters 45 [ rx-jumbo N ] [ tx N ] ethtool -i DEVNAME ethtool -d DEVNAME ethtool -e DEVNAME [ raw on|off ] [ offset N ] [ length N ] ethtool -E DEV.
46 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 Following are some common parameters that can be changed: rx-usecs and rx-frames control the RX interrupt rate per RX DMA channel.
Chapter 5 Configuring the nxge Device Driver P arameters 47 2. T o change RX interrupt Coalesce parameters use the ethtool -C command: 3. T o get status of L4 HW checksumming, use the ethtool -k comma.
48 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 ▼ T o Set Parameters Using the Bundled configtool Utility 1. T o get a list of tunable parameters, use the nxge_config if_name get command: These classification variables define how each IP class is conf igured.
Chapter 5 Configuring the nxge Device Driver P arameters 49 3. T o set a particular variable, use the /usr/local/bin/nxge_config if_name set param_name value : T uning for Maximum Performance on a Lin.
50 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 2. Set up the sysctl utility . # sysctl -p /etc/sysctl_nxge.conf.
51 CHAPTER 6 Conf iguring the Jumbo Frames Featur e This chapter describes how to configure the Jumbo Frames featur e. It contains the following sections: ■ “Jumbo Frames Overview” on page 51 .
52 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 ▼ T o Show the Driver Statistics in a Solaris Envir onment 1. Use the kstat command to display driver statistics, for example: The previous example displays the r eceive packet counts on all of the eight Receive DMA channels on interface 1.
Chapter 6 Configuring the Jumbo F rames Feature 53 Enabling Jumbo Frames in a Solaris Envir onment This section describes how to enable jumbo frames in both a SP ARC and an x86 environment. ▼ T o Enable Jumbo Frames in a Solaris Envir onment Using nxge.
54 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 ▼ T o Check Layer 3 Conf iguration ● Check the Layer 3 conf iguration by using the dladm command with the show- link option, as shown in the following example: Enabling Jumbo Frames in a Linux Envir onment This section describes how to enable jumbo frames in a Linux environment.
Chapter 6 Configuring the Jumbo F rames Feature 55 ▼ T o Show the Driver Statistics in a Linux Envir onment 1. Use the ifconfig utility to display driver statistics, for example: 2. Use the ethtool utility with -S option to get more detailed information.
56 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 3. T o get more specif ic statistics, use the grep command on the output of ethtool - S: # ethtool -S eth9 |grep tx_pac tx_packets: 8.
57 CHAPTER 7 Conf iguring Link Aggregation This chapter describes how to configure link aggr egation. It contains the following sections: ■ “Overview of Link Aggregation” on page 57 ■ “Confi.
58 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 Conf iguring Link Aggregation in a Solaris Envir onment This section explains how to configure link aggr egation in a Solaris environment. ▼ T o Conf igure Link Aggr egation in a Solaris Envir onment 1.
Chapter 7 Configuring Link Aggregation 59 2. Plumb up the interface aggr key , which is aggr33 is this case: 3. Show link-aggregation status again, and now the state should become attached: 4. Use the dladm show-aggr -s command to display statistics: 5.
60 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 Conf iguring Link Aggregation in a Linux Envir onment This section explains how to configure link aggr egation in a Linux environment. ▼ T o Conf igure Bonding for Multiple nxge Interfaces 1.
61 CHAPTER 8 Conf iguring VLANs This chapter explains V irtual Local Area Networks (VLANs) in detail and pr ovides configuration instructions and examples.
62 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 FIGURE 8-1 shows an example network that uses VLANs. FIGURE 8-1 Example of Servers Supporting Multiple VLANs W ith T agging Adapters The example network has the following features: The physical LAN network consists of a switch, two servers, and five clients.
Chapter 8 Configuring VLANs 63 Gigabit Ethernet ports, which is configured for VLANs 1, 2, and 3. Both the adapter and the connected switch port have tagging turned on.
64 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 FIGURE 8-2 Ethernet T ag Header Format By default, a single VLAN is configur ed for every port. This groups all ports into the same broadcast domain, just as if ther e were no VLANs at all, VLAN tagging for the switch port is turned off.
Chapter 8 Configuring VLANs 65 2. Use the ifconfig(1M) to conf igure a VLAN virtual device, for example: The output of ifconfig -a on a system having VLAN devices nxge123000 and nxge224000 : 3. On the switch, set VLAN tagging and set VLAN ports to coincide with the VLANs you’ve set up on the server .
66 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 2. Plumb Oracle’ s Sun x8 Express Dual 10 Gigabit Ethernet Fiber XFP Low Prof ile Adapter interface: where xxx.xxx.xx.xxx = the IP addr ess of the interface. 3. Insert the VLAN module: 4.
67 APPENDIX A Specif ications This appendix lists the specif ications for the Sun x8 Express Dual 10 Gigabit Ethernet Fiber XFP Low Prof ile Adapter. It contains the following sections: ■ “Connect.
68 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 T ABLE A-1 lists the characteristics of the f iber connectors used by the Sun x8 Express Dual 10 Gigabit Ethernet Fiber XFP Low Prof ile Adapter.
Appendix A Specifications 69 Physical Characteristics Power Requir ements T ABLE A-3 Physical Characteristics Dimension Measurement Length 167.65 mm (6.6 inches) W idth 68.90 mm (2.713 inches) Height Component side = 14.48 mm (0.57 inches) maximum Solder side = 2.
70 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010.
71 APPENDIX B Diagnostic Softwar e This appendix provides an overview of the SunVTS diagnostic application and instructions for updating the SunVTS software to r ecognize the adapter .
72 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010 http://www.sun.com/products-n-solutions/hardware/docs/Software /system_administration/tools/testing_valid/sunvts/index.html Select the document for the Solaris release on your system. Updating SunVTS to Recognize the Adapter Use SunVTS 6.
Appendix B Diagnostic Software 73 Using the SunVTS netlbtest Y ou must have the Ethernet card and the device driver installed, a loopback connector in place, and Intervention mode enabled before running netlbtest .
74 Sun Dual 10GbE XFP PCI Express Card User’s Guide • May 2010.
75 Index Symbols /etc/hostname.nxge number f ile ,2 4 A assigning an IP address, 24 C configuring the network host files, 23 configuring VLANs, 63 D diskless clients, 25 documentation SunVTS, 72 E .
76 Sun Dual 10GbE XFP PCI Express Card User’ s Guide • May 2010.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Oracle Audio Technologies SunDual 10GbE XFP è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Oracle Audio Technologies SunDual 10GbE XFP - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Oracle Audio Technologies SunDual 10GbE XFP imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Oracle Audio Technologies SunDual 10GbE XFP ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Oracle Audio Technologies SunDual 10GbE XFP, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Oracle Audio Technologies SunDual 10GbE XFP.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Oracle Audio Technologies SunDual 10GbE XFP. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Oracle Audio Technologies SunDual 10GbE XFP insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.