Manuale d’uso / di manutenzione del prodotto Omnitron 8000-0 del fabbricante Omnitron Systems Technology
Vai alla pagina of 25
iConverter ® Network Management Module USER MANUAL Release 3.4.
Page 2 T able of Contents 1.0 Overview .................................................................................................................... 3 2.0 Port S tructure .........................................................................
1.0 OVERVIEW The iConverter ® Network Management Module (NMM) is the heart of the iConverter management system. It features a 32-bit, high performance RISC microprocessor executing a realtime operating system. It supports the SNMP and T elnet protocols and is capable of controlling up to 19 managed chassis.
2.0 PORT STRUCTURE 2.1 OVERVIEW The Network Management Module front panel provides the access to the Management ports. Management can be accessed through the serial port or the UTP port. The module features a backplane Ethernet port for connectivity to adjacent modules.
The illustration below shows how multi-chassis are managed using Omnitron’ s NetOutlook Management Software. From the chassis view screen, each of the chassis are available. NetOutlook Chassis V iew Multi-chassis configuration can also be managed through the serial console port.
The iConverter 19-Module, 5-Module and 2-Module Chassis backplanes provide ethernet data connectivity between adjacent slots. The A and B backplane ports connect the slots as illustrated.
The backplane data bus supports Out-of-Band Management and In-Band Management configurations. Out-of-Band Management Out-of-Band Management is available by directly connecting the Network Management Station (NMS) to the UTP port on the front of the NMM.
3.0 INST ALLA TION PROCEDURE 3.1 OVERVIEW The following steps outline the installation and configuration procedures for the NMM. Refer to the specified sections for detailed instructions. • Configuring Switches (Section 3.2) • Installing the Module and Connecting the UTP Cable (Section 3.
3.4 CONFIGURE THE MODULE VIA COMMAND LINE INTERF ACE T o configure, attach the NMM to a DB-9 serial (RS-232) equipped computer with terminal emulation software such as HyperT erminal. Using a standard serial cable, connect the serial port of the PC and the Serial Console Port of the NMM.
The Management Options screen will be displayed. Management Options iConverter, Serial Agent Network Management 1: Chassis and Module Management 2: Set Module Identifier Management Module Preferences .
3.4.1 Setting IP and Control Preferences An IP address is required for the SNMP or T elnet access. The factory default setting is 192.168.1.220. The IP address can be configured manually or automatically as a DHCP client.
3.4.1.2 Setting IP Parameters as DHCP Client T o configure the IP automatically as a DHCP client, select 9 from the Management Options screen. The Other Networking Features screen will appear .
T o set the Chassis Name, select 5 at the IP and Control Preferences screen, press <ENTER> and follow the instructions to enter the chassis name. IP and Control Preferences Screen iConverter, Serial Agent 1: Set IP 192.168.1.220 2: Set Subnet Mask 255.
3.4.2 Setting SNMP Preferences T o set the SNMP Preferences for the NMM, select 4 from the Management Options screen, press < ENTER > to enter the SNMP Preferences screen.
Page 15 The module supports the three levels of Authentication and Encryption (Security Levels) for User 1 and User 2; noAuthNoPriv , authNoPriv and authPriv . noAuthNoPriv uses username for authentication, authNoPriv provides authentication based on the HMAC-MD5 algorithm and authPriv provides DES 56-bit encryption based on the HMAC-MD5 algorithm.
3.4.3 Management Support 3.4.3.1 VLAN The NMM Management Processor can independently transmit and receive Management Data with an IEEE 802.1Q tag. T o enable and configure this feature, type 9 from the Management Options screen to access the Other Networking Features screen.
switch settings, then the module’ s hardware settings take effect. T o set the Soft-switch Reload function, select 8 at the IP and Control Preferences screen, press < ENTER > and then follow the screen prompts to change the setting. IP and Control Preferences Screen iConverter, Serial Agent 1: Set IP 192.
Page 18 3.4.5 Access the NMM Remotely Remote access to the NMM is provided via SNMP , T elnet, FTP or an external serial modem connected to the Serial Console Port.
IP and Control Preferences Screen iConverter, Serial Agent 1: Set IP 192.168.1.220 2: Set Subnet Mask 255.255.255.0 3: Set Gateway 192.168.1.1 4: Chassis Number 1 5: Chassis Name (also sysName) NMM 6:.
Page 20 3.4.5.4 Up dating the NMM Firmware via FTP Using an FTP application, upload the new firmware into the FTP root directory of the NMM. When the file transfer is complete, the NMM verifies the file and then automatically restarts with the newly loaded firmware.
4.0 MODULE ST A TUS 4.1 OVERVIEW The Module status screen provide information on the NMM. The Module status screen is accessible by selecting the module slot number from the Chassis V iew screen. T o access the Module status screen, select 1 at the Management Options screen, press < ENTER >.
Module - iConverter NMM iConverter, Serial Agent Identifier - Chassis Number = 1 Slot Number = 1 Model Number = 8000-0 Serial Number = xxxxxxxx Manufacturing Date = xxxxxxxx Hardware Revision = xx Sof.
5.0 NMM SPECIFICA TIONS Prot ocol s I P , UD P , S NMP v 1 , S NMP v2c, S NMP v 3 , TC P , AR P , I C M P , T el n et , FT P , 802. 3ah Copper Connect ors R J -4 5 , D B -9 Contr ol s UTP C r o s s o .
6.0 TROUBLESHOOTING GUIDE 6.1 OVERVIEW The NMM module has several LED indicators available to assist in the determination of problems. Refer to Section 3.5, V erify Operation, for LED definitions. 6.1.1 Power Issues Problem: The Power LED does not illuminate after installation is complete or no LED indicators ar e ON Possible Causes: A.
7. 0 WARRANTY This product is warranted to the original purchaser against defects in material and workmanship for a period of TWO YEARS from the date of shipment. A LIFETIME warranty may be obtained by the original purchaser by REGISTERING this product with Omnitron within 90 days from the date of shipment.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Omnitron Systems Technology Omnitron 8000-0 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Omnitron Systems Technology Omnitron 8000-0 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Omnitron Systems Technology Omnitron 8000-0 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Omnitron Systems Technology Omnitron 8000-0 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Omnitron Systems Technology Omnitron 8000-0, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Omnitron Systems Technology Omnitron 8000-0.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Omnitron Systems Technology Omnitron 8000-0. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Omnitron Systems Technology Omnitron 8000-0 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.