DPG10L LARGE DISPLA Y PRESSURE GAUGE M3367/0606 User’ s Guide http://www .omega.com e-mail: info@omega.com.
Where Do I Find Ever ything I Need for Pr ocess Measurement and Contr ol? OMEGA...Of Course! TEMPERA TURE ✓ Thermocouple, R TD & Thermistor Probes, Connectors, Panels & Assemblies ✓ W ire:.
T able of Contents W arranty/Disclaimer ........................................................................2 Return Requests/Inquiries ................................................................3 Instructions ................................
• W arranty/Disclaimer OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA ’ s W arranty adds an additional one (1) month grace period to the normal one (1) year pr oduct warranty to cover handling and shipping time.
• Return Requests/Inquiries Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBT AIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA ’S CUSTOMER SER VICE DEP AR TMENT (IN ORDER T O A VOID PROCESSING DELA YS).
• Instructions The model DPG10L Digital Pressure Gauge has several features not normally found as standard in Digital Pressure Gauges. These include the Analog Scale, T are, and Peak Holds. The Analog Scale is a 40 segment display that appears around the edge of the liquid crystal display .
2.3 T o disengage Hold press and hold the “MODE” key until the reading starts flashing. Release the “MODE” key then press the “MODE” key once more, the display will read “HOLD”. Press the “ENTR” key , the display will read “NO H” Press the “ENTR” key once more and the display will return to reading the system pressure.
3.5 The alarm set point indicator segment of the bar graph will “blink” when that set point is activated. The hookup of optional outputs is covered later in this manual 4.0 Zero T rimming 4.1 Should it be necessary to readjust the Zero setting, an adjustment has been provided.
• DPG10L Output Options Several output signals are available on the circular 6 pin connector located on the rear of the unit. Depending on the option selected the signals are present on pins as follows.
• Wiring A B C D – EXCITATION + EXCITATION Gauge Connector Typical 4-20 mA Circuit 4-20 mA CURRENT LOOP E F – EXCITATION + EXCITATION Gauge Connector Typical 0-5 VDC Circuit + SUPPLY VOLTAGE + O.
OMEGA ’ s policy is to make running changes, not model changes, whenever an improvement is possible. This af fords our customers the latest in technology and engineering. It is the policy of OMEGA to comply with all worldwide safety and EMC/ EMI regulations that apply .
OMEGAnet ® On-Line Service Internet e-mail www .omega.com info@omega.com Servicing Nor th America: USA: One Omega Drive, P .O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 TEL: (203) 359-1660 F AX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1 TEL: (514) 856-6928 F AX: (514) 856-6886 e-mail: info@omega.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Omega Engineering DPG10L è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Omega Engineering DPG10L - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Omega Engineering DPG10L imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Omega Engineering DPG10L ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Omega Engineering DPG10L, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Omega Engineering DPG10L.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Omega Engineering DPG10L. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Omega Engineering DPG10L insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.