Manuale d’uso / di manutenzione del prodotto M165957K del fabbricante North Star
Vai alla pagina of 41
M165957K Owner’s Manual Instructions for Installation/Set-u p, Operation, Serv icing, & Storage Portable, Outdoor Use-Only, Gasoline Generator 6600 Watt Continuous (8000 Watt Surge) Capacity Can.
Hazard Signal Word Definitions 2.
Table of Contents 3 Hazard Signal Word Definitions ................................................................................................. .2 About Your Generator ..............................................................................
About Your Generator 4 Thank you for purchasing your NorthStar portable generator! About Your Generator This engine-driven, portable generator is designed to provide up to 8000 Watts of electrical power (6600 watts continuous, 8000 watts surge). It can supply power: 1.
About Your Generator (cont’d) 5 NorthStar is constantly improving its products. The specifications outline d herein are subject to change without prior notice or obligation. Th e purchaser and/or user shall assume liability for any modification and/or alterations of this equipm ent from original design and manufacture.
Specifications – Item #165957K 6 SPECIFICATIONS Item Number #165957 Maximum Output 8000 Watts (W) Continuous Output 6600 Watts (W) Voltage 120 / 240 Volt (V) Phase Single phase (4-wire) Frequency 56.5-63.3 Hertz (Hz) Power Factor 1.0 p.f. Engine 13 HP Honda GX390 Engine Speed 3390-3800 RPM Fuel Type Unleaded gasoline Fuel Capacity 6.
Safety Label Locations – Item #165957K 7 Always make sure safety labels are in place and in good condition. If a safety label is missing or not legible, order new la bels or unsafe operation could result. To order replacement safety labels , call NorthStar Product Support at 1-800-270-0810.
Machine Component Identification - Item #165957K 8 Figure 1 (Ref. 1-8) 00591 Ref. Description Ref. Description 1 Circuit Breakers 10 Gas Cap with Gauge 2 120/240V 30A Locking device Receptacle 11 6.
Machine Component Identification - Item #165957K 9 REFERENCE GUIDE Reference 1 – Circuit Breakers This portable single phase generator has 1, 15 amp (A) 2, 20A, and 2, 30A push to reset circuit breakers to protect against electrical overloads. Reference 2 – 120/240V Receptacle The locking device is a 120/240V 30A NEMA L14-30R receptacle.
Power Load Planning & Management 10 WARNING NEVER exceed the rated wattage capacity of your generator. OVERLOADING may cause SERIOUS DAMAGE to the generator and attached electrical devices, and may result in fire. Your generator MUST BE SIZED PROP ERLY to provide both the running and starting (surge) wattage of the devices you will be powering.
Power Load Planning & Management (cont’d) 11 Device Running Watts Device Running Watts Furnace fan (1/3 HP) 1200 (a) Submersible pump (1-1/2 HP) 2800 (a) Freezer 800 (b) Submersible pump (1 HP) .
Installation / Initial Set-Up 12 There are a number of important steps required to set up your generator for initial use. These steps are: Steps for Installation / In itial Se t-Up 1. Unpacking & delivery inspection. 2. Planning the power load to stay within the generator’s rated capacity.
Installation / Initial Set-Up 13 3. Set-up either as a BUILDING BACK-UP or PORTABLE Power Source This generator is designed to provide up to 8000W of electrical power. It can supply electricity in two ways: 1. As a back-up, standby power source for a building.
Installation / Initial Set-Up 14 Ple ase re ad you r owner's manu al bef ore op eratin g, if you do not have a m anual or ha ve qu esti ons, cal l cu stomer servi ce a t 1-800-270-0810 GROUNDING PO ST N EMA L14-30R NEMA 5-20 R Duplex NEMA 5-15 R FIG02679 that have been chosen as critical to operate during a power outage.
Installation / Initial Set-Up 15 ♦ Extension cords may be used to pow er devices that are located at a distance from the generator. Howeve r, use only UL-listed, outdoor-rated, grounded extension cords of the proper size.
Installation / Initial Set-Up 16 4. Select a Suitable Site Before using the generator, you must select a suitable OUTDOOR location for installation and operation.
Installation / Initial Set-Up 17 • Situate so there is adequate clear ance around generator to allow for cooling airflow so that heat does not build up. • Never place the generato r imm ediately adjacent to a building or other structure – allow at least a 7’ clearance.
Installation / Initial Set-Up 18 5. Grounding the generator Always ensure the generator is properly grou nded to prevent electrical shock. You must always ground the generator by the fo llowing method when using the generator as a portable electrical source: 1) Drive a ¾” or 1” copper pipe or rod into the ground close to the generator.
Installation / Initial Set-Up 19 6. Battery Installation Your generator’s engine is equipp ed with an electric starter which require s the installation of a 12- volt lawn tractor size battery (Gr oup U1).
Operation 20 Once you have set up your generator for use, it is time to start your generator. The following are the procedures necessa ry for safe, successful operation of your generator. Operation Procedures 1. General Safety Rules for Operation 2. Preparing for Operation 3.
Operation (cont’d) 21 • Malfunction during operation. Immediately turn off the generator if an y of the following conditions arise during operation: o Excessive change in engine speed, slow or fas.
Operation (cont’d) 22 Static electricity and filling the gasoline tank: Static electricity can initiate from ungrounded gasolin e tanks or containers, from flowing gasoline, and from persons carryin.
Operation (cont’d) 23 2. Preparing for Operation Position generator Position generator in accordance with the instructions g iven in “Installation & Initial Set-up, Step 4: Select a Suitable Site” of this manual. Operate outside only, on dry, level gr ound with adequate clearance and ventilation.
Operation (cont’d) 24 WARNING : Gasoline fire/explosion hazard Gasoline is highly flammable and expl osive. Heat, sparks, and flames can ignite gasoline vapors, which can become widespread during fueling. A flash fire and/or explosion could result and cause serious injur y or death.
Operation (cont’d) 25 ground to be filled. • Keep nozzle i n contact with portabl e container while filling. Manually control the flow of gasoline; do NOT use the nozzle’s lock-open device. • A portable container made of metal or conductive plastic is preferred because it dissipates charge to ground more readily.
Operation (cont’d) 26 3. Starting the Engine After you have completed the pre-start checklist procedures, you are ready to start the engine. To start the engine: 1) Disconnect all load s to the generator. 2) Turn the gasoline line valve to the ON positio n.
Operation (cont’d) 27 4. Checking Generator Output Although the speed of the engine was carefully adjusted at the factory so that the generator produces the proper voltage and frequency, output voltage should be checked periodically to ensure the generator is working properly before connecting loads to the generator .
Operation (cont’d) 28 5. Connecting Loads You will want to be careful when connecting loads so as not to overload the generator, especially if you are powering devices with motors that require a higher starting power load.
Operation (cont’d) 29 7. Storage & Exercise When you are finished usin g the generator, you must: o Disconnect all loads o Shut off fuel supply o Store the generator properly o Plan on exercising the engine regularly unless the generator is prepared for long-term storage.
Operation (cont’d) 30 Prepare engine for long term storage if needed If you will not be able to exercis e the generato r regularly, you must prepare the engine for long term storage to prevent gum deposits from forming and causing malfunction of the engine.
Maintenance & Repair 31 Inspect and maintain your generator as specified below in order to keep it in safe and optimal working order. Follow all safety ru les and recom mended maintenance steps. WARNING ALWAYS shut off the engine, disconnect the spark plug(s) and discharge the capacitor before cleaning, adjusting, or servicing the ge nerator.
Maintenance & Repair (cont’d) 32 Check GFCI (if equipped) Once a month, test the Ground Faul t Circuit Interrupter (GFCI) to protect against electrical shock due to failure of the GFCI. (Only for those models equipped with GFCI – See the “Specifications” section.
Troubleshooting 33 TROUBLESHOOTING Problem Possible Causes Possible Remedies Engine will not start. a) Low oil level. b) Fouled spark plug. c) Out of fuel. d) Stop switch in OFF position. e) Battery is not charged. a) Fill crankcase to proper oil level.
Summary of Important Safety Information for Operation 34 This section provides a summary of the various safety procedures and measures that have been presented throughout the manual. Keep this summ ary handy and refer to it to refresh your memory about how to safely use your generator.
Summary of Important Safety Information for Operation (cont’d) 35 Installation / Initial Se t-up Safety • Dry, level surface . Situate generator on a dry, firm, level surf ace. Ensure generat o r sits level and will not slide or shift during operation.
Summary of Important Safety Information for Operation (cont’d) 36 Gasoline Safety Gasoline is highly flam mable and expl osive. Y ou can be burne d or seriously inju red when handling fuel . Use extreme care when handling: • Fuel outdoors . Fill fuel tank outdoors – never indoors.
Summary of Important Safety Information for Operation (cont’d) 37 • Avoid cont act . Avoid contact with bare wires, terminals, connections, etc. while the unit is running . • Electric shock accident. If an electric shoc k accident occurs, imme diately shut down the source of electrical power.
Generator Exploded View Rev - K 38.
Generator Exploded View Rev - K 39 Ref # Part # Description Qty 1 38759 Fuel Tank Assembly 1 2 33321 Fuel Cap 1 3 777352 Battery Box 1 4 30754 Leather Washer 4 5 779422 Decal 1 6 777834 Hose Clamp 3 7.
Wiring Diagram Rev - K 40 Diag # Part # Description Qty 1 306438 15 Amp, 120 Volt Receptacle (NEMA 5-15R) 1 2 31736 20 Amp, 120 Volt Receptacle (NEMA 5-20R) 1 3 306422 30 Amp, 120/240 Volt Locking Rec.
Generator Head Exploded View Rev - K 41 Item # Part # Description Qty 1 38266 Mount Plate (J609B) 1 2 38267 Fan Bolts 2 3 38268 Fan 1 4 38269 Drive End Bracket 1 5 38270 Enclosing Band 1 6 777304 End .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il North Star M165957K è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del North Star M165957K - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso North Star M165957K imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul North Star M165957K ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il North Star M165957K, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del North Star M165957K.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il North Star M165957K. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo North Star M165957K insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.