© 2000-2005 LZB 119 2663 R8 T echnical Product Manual DCT1900 System No part of this manual may be reproduced in any form, by print, photoprint, microfilm, or any other means without prior written permission of the copyright own er .
© 2000-2005 LZB 119 2663 R8.
Technical Product Manu al - DCT1900 Preface Preface-DCT1900/R8/mw 1 © 2000-2005 Preface What this manual describes ... This manual describes how to configure, inst all, maintain and op erate the DCT1900 Cordless T elephone System.
Technical Product Manual - DCT 1900 Preface 2 Preface-DCT1900/R8/mw © 2000-2005 maintain the system with th e help of the system's internal dia gnostics and test facilities, and by using fault finding pro cedures. Section 8 Glossary This section contains ab breviations used in this manual.
Technical Product Manu al - DCT1900 Safety and Regulatory Information Safety-DCT1900/R8/mw © 2000-2005 Section 1 Safety and Regulatory Information.
Technical Product Manual - DCT 1900 Safety and Regulatory Information Safety-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Safety and Regulatory Information, Table of Contents Safety-DCT1900/R8/mw I © 2000-2005 T able of Contents C HAPTER 1 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Product Manual - DCT 1900 Safety and Regulatory Information, Table of Contents II Safety-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Safety and Regulatory Information, Safety Safety-DCT1900/R8/mw 1-1 © 2000-2005 C HAPTER 1 Safety 1.1 General z Never install telephone wirin g during a lightning storm. z Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.
Technical Product Manual - DCT 1900 Safety and Regulatory Information, Safety 1-2 Safety-DCT1900/R8/mw © 2000-2005 1.2 Electrost atic Sensitive Devices 1.3 Lithium Battery on CPU Board The following warning is applicable for the Lithium battery on the CPU board.
Technical Product Manu al - DCT1900 Safety and Regulatory Information, Standards and R egulations Safety-DCT1900/R8/mw 2-1 © 2000-2005 C HAPTER 2 S t andards and Regulations 2.1 St andards and Regulations The DCT1900 System adhe res to the following sta ndards and regulations: z FCC Part 15 z UL 60950 z UT AM, Inc.
Technical Product Manual - DCT 1900 Safety and Regulatory Information, Standards and Regulations 2-2 Safety-DCT1900/R8/mw © 2000-2005 FCC P ART 15 THIS DEVICE COMPLIES WITH P ART 15 OF THE FCC RULES.
Technical Product Manu al - DCT1900 Safety and Regulatory Information, Standards and R egulations Safety-DCT1900/R8/mw 2-3 © 2000-2005 THE TERM "IC:" BEFORE THE RA DIO CERTIFICA TION NUMBER ONL Y SIGNIFIES THA T INDUSTR Y OF CANADA TECHNICAL SPECIFICA TION WERE MET .
Technical Product Manual - DCT 1900 Safety and Regulatory Information, Standards and Regulations 2-4 Safety-DCT1900/R8/mw © 2000-2005 Exposure to Radio Freq uency Signals (SAR) Y our wireless phone is a radio transmitter and receiver .
Technical Product Manu al - DCT1900 Safety and Regulatory Information, Protec tion against Electrosta tic Discharge (ESD) Safety-DCT1900/R8/mw 3-1 © 2000-2005 C HAPTER 3 Protection against Electrost atic Discharge (ESD) 3.1 General Integrated circuits are sensitive to ESD .
Technical Product Manual - DCT 1900 Safety and Regulatory Information, Protec tion against Electrostatic Discharge (ESD) 3-2 Safety-DCT1900/R8/mw © 2000-2005 IMPORT ANT NOTE In the interest of qualit.
Technical Product Manu al - DCT1900 System Description System-DCT1900/R8/mw © 2000-2005 Section 2 System Description.
Technical Product Manual - DCT 1900 System Description System-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 System Description, Table of Contents System-DCT1900/R8/mw I © 2000-2005 T able of Contents C HAPTER 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Product Manual - DCT 1900 System Description, Table of Contents II System-DCT1900/R8/mw © 2000-2005 4.13 Digital Line Unit - DLU (AW S1026) Lucent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10 4.14 Modular Cabi net Connection Board-MCCB (ROANB 101 28) .
Technical Product Manu al - DCT1900 System Description, Introduction System-DCT1900/R8/mw 1-1 © 2000-2005 C HAPTER 1 Introduction The DCT1900 system is a pi co–cellular , digital cord less teleph one system that can be conn ected to a PBX or a Mobility Server via T1 or E1 links or standard analog ports.
Technical Product Manual - DCT 1900 System Description, Introduction 1-2 System-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 System Description, System Overview System-DCT1900/R8/mw 2-1 © 2000-2005 C HAPTER 2 System Overview The DCT1900 system may operate as a standalone system or as a mobility system when used in conjunction with the Mobility Server .
Technical Product Manual - DCT 1900 System Description , System Overview 2-2 System-DCT1900/R8/mw © 2000-2005 T able 2-1 DCT1900 Network Signalling Summary DCT1900 System Ty pe Signalling Format to Network Signalling Functionality Provides Connection to S t andalone Analog Interface is over a 3Khz analog 2-wire connection.
Technical Product Manu al - DCT1900 System Description, System Overview System-DCT1900/R8/mw 2-3 © 2000-2005 Fig. 2-1 System Over view DCT1900 S t andalone Enviro nment RE PBX/CO BS BS CSM P T P T P .
Technical Product Manual - DCT 1900 System Description , System Overview 2-4 System-DCT1900/R8/mw © 2000-2005 Fig. 2-2 System Overview DCT1900 Mobility Environment PBX/CO PBX/CO RE RE RE CSM CSM CSM BS BS BS BS BS P T P T P T P T P T Sw.
Technical Product Manu al - DCT1900 System Description, System Overview System-DCT1900/R8/mw 2-5 © 2000-2005 In Figures 2-1 & 2-2 the relevant prod ucts covered by this manual are marked in gray .
Technical Product Manual - DCT 1900 System Description , System Overview 2-6 System-DCT1900/R8/mw © 2000-2005 System Architecture The DCT1900 system provides a wireless infr astr ucture between the user and the MS/PBX. The system can serve multiple users at the same time.
Technical Product Manu al - DCT1900 System Description, System Overview System-DCT1900/R8/mw 2-7 © 2000-2005 will still synchronize slaves connecte d to it, ef fectively forming a se parate "sub cluster" within which seamless handovers are still possible.
Technical Product Manual - DCT 1900 System Description , System Overview 2-8 System-DCT1900/R8/mw © 2000-2005 De–registrat ion De–registratio n is the process where the author ization at registration is removed. Once the user is de-register ed, he can no lon ger be reache d.
Technical Product Manu al - DCT1900 System Description, System Overview System-DCT1900/R8/mw 2-9 © 2000-2005 2.2 Roaming and Handover Handling by the Port able T elephone Sections 2.
Technical Product Manual - DCT 1900 System Description , System Overview 2-10 System-DCT1900/R8/mw © 2000-2005 System St atus A Portable T elephone cont a ins a list of the curren t RE st atus. For each system, th e status may be: NOT_ALLOWED: The Portable T elephone is not allowed to access this RE.
Technical Product Manu al - DCT1900 System Description, System Overview System-DCT1900/R8/mw 2-1 1 © 2000-2005 V olunt ary Int ra System Handov er If the best bearer of anoth er Base S t ation is at lea st 6dB or better durin g a number of consecutive frames, the Portable T elephone will star t a handover to that Base S t ation.
Technical Product Manual - DCT 1900 System Description , System Overview 2-12 System-DCT1900/R8/mw © 2000-2005 Message W aiting Indicatio n With this feature the PBX will be ab le to inform the user (on his Port able T elephone display) that there is a pending message in his/her voicemail bo x and/or short messag e list.
Technical Product Manu al - DCT1900 System Description, System Overview System-DCT1900/R8/mw 2-1 3 © 2000-2005 Conference Call The user of the Portable T elepho ne has possibility to invite other extensions or ou tside telephone numbers to jo in a conference call.
Technical Product Manual - DCT 1900 System Description , System Overview 2-14 System-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 System Description, Ha rdware Buildin g Blocks System-DCT1900/R8/mw 3-1 © 2000-2005 C HAPTER 3 Hardware Building Blocks The hardwa re building blocks of the DCT1900 system are ( see Figure 3- 1) z RE z Base S t ations z Portab le T elephones Fig.
Technical Product Manual - DCT 1900 System Description, Hardware Building Blocks 3-2 System-DCT1900/R8/mw © 2000-2005 Message Se rvice (SMS) source. T he printer can p rint a hardcopy of the system error messages. In a multiple system configuration, up to 13 RE’s can be cascaded toge ther .
Technical Product Manu al - DCT1900 System Description, Radio Exchange Boards System-DCT1900/R8/mw 4-1 © 2000-2005 C HAPTER 4 Radio Exchange Boards 4.
Technical Product Manual - DCT 1900 System Description, Radio Exchange Boards 4-2 System-DCT1900/R8/mw © 2000-2005 4.3 Speech Link Unit – SLU (REX-BRD0015 or ROFNB 157 16/1 ) The SLU is a combination of an SPU and a CLU on one bo ard. It contains eight SPC (see Figur e 4-1) and eight CLC (see Fi gure 4-1).
Technical Product Manu al - DCT1900 System Description, Radio Exchange Boards System-DCT1900/R8/mw 4-3 © 2000-2005 4.4 Speech Processing Unit - SPU-S (REX-BRD0017 or ROFNB 157 16/3 ) The SPU interfaces between a L TU/DT U and a CLU/ SLU. Every SPU board cont ains eight S peech Processing Channels (SPC, see Figure 4 -2).
Technical Product Manual - DCT 1900 System Description, Radio Exchange Boards 4-4 System-DCT1900/R8/mw © 2000-2005 4.5 Cell Link Unit - CLU (REX-BRD0014 or ROFNB 157 1 1/2 ) or CLU-S (REX-BRD0016 or ROFNB 157 16/2 ) The CLU inte rfaces between a SPU and a Base S tation.
Technical Product Manu al - DCT1900 System Description, Radio Exchange Boards System-DCT1900/R8/mw 4-5 © 2000-2005 4.6 Digit al T runk Unit - DTU-E1 4.6.1 CCS - REX-BRD0003 or 2/ROFNB 157 13/6 The DTU provides the digit al inter face between the MS and the RE.
Technical Product Manual - DCT 1900 System Description, Radio Exchange Boards 4-6 System-DCT1900/R8/mw © 2000-2005 4.6.2 CAS - REX-BRD0002 or 2/ROFNB 157 13/1 DTU-E1 CAS is used only in st andalone configurations. The DTU provides the digit al interface between the PBX and the RE.
Technical Product Manu al - DCT1900 System Description, Radio Exchange Boards System-DCT1900/R8/mw 4-7 © 2000-2005 4.7 Digit al T runk Unit - DTU-T1 CAS (R EX-BRD0021 or 2/ROFNB 157 13/2 ) DTU T1 CAS is used only in S tandalone configur ations. The DTU provides the digi t al interface between the PBX and the RE.
Technical Product Manual - DCT 1900 System Description, Radio Exchange Boards 4-8 System-DCT1900/R8/mw © 2000-2005 4.8 Digit al T runk Unit-DTU -T1 CCS ( REX-BRD0025 or 2/ROFNB 157 13/3 ) The DTU provides the digit al inter face between the MS and the RE.
Technical Product Manu al - DCT1900 System Description, Radio Exchange Boards System-DCT1900/R8/mw 4-9 © 2000-2005 4.9 Line T ermination Unit - L TU (REX-BRD0007 or ROFNB 157 02/6 ) L TU2 (REX-BRD0019A or ROFNB 157 25/2) L TUs are used only in S tandalone configurations .
Technical Product Manual - DCT 1900 System Description, Radio Exchange Boards 4-10 System-DCT1900/R8/mw © 2000-2005 4.10 Digit a l Line Unit - DL U (REX-BRD0023) Basic Board The Digital Li ne Unit (DLU) card is used only in standalone configurations.
Technical Product Manu al - DCT1900 System Description, Radio Exchange Boards System-DCT1900/R8/mw 4-1 1 © 2000-2005 4.14 Modular Cabinet Connecti on Board-MCCB (ROANB 101 28) The MCCB provides conne.
Technical Product Manual - DCT 1900 System Description, Radio Exchange Boards 4-12 System-DCT1900/R8/mw © 2000-2005 Fig. 4-10 Hardware Block Diagram of the DCT1900 System housed in a Modula r Ca binet Note: Numbers in ( ) are circuit s per board. CLU (8) CLU (8) SPU (8) SPU (8) DTU (2) CPU DC Mobi lity Server/P BX Radio Exchange .
Technical Product Manu al - DCT1900 System Description, Other System Aspects System-DCT1900/R8/mw 5-1 © 2000-2005 C HAPTER 5 Other System Aspect s 5.1 Inst allation and Maintenance As each DCT1900 system is configured to meet specific user requirement s, the RE must be assembled on location.
Technical Product Manual - DCT 1900 System Description, Other System Aspects 5-2 System-DCT1900/R8/mw © 2000-2005 5.3.3 Characteristics Frequency band : 19 20-1930 MHz Number of carriers : 8 adjacent Carrier spacing : 1.
Technical Product Manu al - DCT1900 System Description, Other System Aspects System-DCT1900/R8/mw 5-3 © 2000-2005 5.4 Numbering Conventions Figures 5-1 an d 5- 2 sh ow how ca bin ets, boards , per iph e ra ls, CL Cs, L TCs and DTCs are numbered. T he cabinet containing t he CPU board is def ined as Cabinet 1.
Technical Product Manual - DCT 1900 System Description, Other System Aspects 5-4 System-DCT1900/R8/mw © 2000-2005 Base St ation Numbering Base S t ations are identified by hexa decimal number s 08-FF which are referr ed to as Base S tation numbers or Base S tation identities.
Technical Product Manu al - DCT1900 Product Specifications Specs-DCT1900/R8/mw © 2000-2005 Section 3 Product S pecifications.
Technical Product Manual - DCT 1900 Product Specifications Specs-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Product Specifications, Table of Contents Specs-DCT1900/R8/mw I © 2000-2005 T able of Contents C HAPTER 1 Portable Telephones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Product Manual - DCT 1900 Product Specifications, Table of Contents II Specs-DCT1900/R8/mw © 2000-2005 4.1.2 Rapid Batter y Charger Kit - BML 16 2 1016/72 Discontinued . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 4.1.3 Rapid Desk Charger - BML 162 1001 .
Technical Product Manu al - DCT1900 Product Specifications, Table of Contents Specs-DCT1900/R8/mw III © 2000-2005 C HAPTER 7 Firmware (on EPROM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1 7.1 CPU DCT1900 Firmware (Mobilit y) - RYS 105 447.
Technical Product Manual - DCT 1900 Product Specifications, Table of Contents IV Specs-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Product Specifications, Portable Telephones Specs-DCT1900/R8/mw 1-1 © 2000-2005 C HAPTER 1 Port able T elephones 1.1 DT600 Port able T e lephone - KRC 101 1372 (no antenna), DARLA (Discontinued) Compliance to Regulations and S t andards Safety S t andards : UL 19 50 ANSI S t andards : C 63.
Technical Product Manual - DCT 1900 Product Specifications, Portable Telephones 1-2 Specs-DCT1900/R8/mw © 2000-2005 User Interface Ringer volume levels : 12 Display : LCD, 12 active dot matrix, backlit T op indicator : LED (red/green) for st atus indication Keypad : 17 hard keys, backlit V olume control : 2 side volume keys Number memory : approx.
Technical Product Manu al - DCT1900 Product Specifications, Portable Telephones Specs-DCT1900/R8/mw 1-3 © 2000-2005 Receiver sensitivity : typical -93 dBm and a minim um receiver sens itivity of -90 dBm with a B.
Technical Product Manual - DCT 1900 Product Specifications, Portable Telephones 1-4 Specs-DCT1900/R8/mw © 2000-2005 Receiver Radi o Specific at io n s Receiver sensitivity : typical -93 dBm and a minim um receiver sens itivity of -90 dBm with a B.E.R.
Technical Product Manu al - DCT1900 Product Specifications, Base Stations Specs-DCT1900/R8/mw 2-1 © 2000-2005 C HAPTER 2 Base St ations 2.1 Base St ation - KRC 101 1371 **T o order a comple te Base S.
Technical Product Manual - DCT 1900 Product Specifications, Base Stations 2-2 Specs-DCT1900/R8/mw © 2000-2005 Receiver Radi o Specific at io n s All specifications mentioned here ar e measured on the RF connector . Receiver sensitivity : ty pical - 92 dBm with a B.
Technical Product Manu al - DCT1900 Product Specifications, Base Stations Specs-DCT1900/R8/mw 2-3 © 2000-2005 2.2 Straight Antenn a - KRE 101 1733/55 This is a half-wave, dipole antenna . This antenna is removable, plug- in type with a polarized MCX (OSX) mating interface.
Technical Product Manual - DCT 1900 Product Specifications, Base Stations 2-4 Specs-DCT1900/R8/mw © 2000-2005 2.4 Mounting Kit s 2.4.1 Out door/W all Mounting Kit - NTM 201 1718 DCT1900 Base S tations may be mounted in a weat herproof fiberglass housing.
Technical Product Manu al - DCT1900 Product Specifications, Batteries Specs-DCT1900/R8/mw 3-1 © 2000-2005 C HAPTER 3 Batteries 3.1 Batteries for the DT600 3.1.1 High Cap acity NiMH - BKB 193 1021 Environment al T emperature Operating : 32 to 1 13 ° F (0 to 45 ° C) S t orage : -4 to 1 13 ° F (-20 to 45 ° C) General Specifications Size : 1.
Technical Product Manual - DCT 1900 Product Specifications, Batteries 3-2 Specs-DCT1900/R8/mw © 2000-2005 3.2 Batteries for the DT620 3.2.1 High Cap acity NiMH Battery - BKB 193 104/75 Environment al.
Technical Product Manu al - DCT1900 Product Specifications, Batteries Specs-DCT1900/R8/mw 3-3 © 2000-2005 3.3 Batteries for the 9p23 3.3.1 Messenger Battery - 643100 General Specifications Weight : 2.7 oz. (76.5 g) Material housin g : PC/ABS Color : Black T y pe : NiMH V oltage : 3.
Technical Product Manual - DCT 1900 Product Specifications, Batteries 3-4 Specs-DCT1900/R8/mw © 2000-2005 3.3.4 Medic Battery with headset connection- 643103 Weight : 2.7 oz. (76.5 g) Material housin g : PC/ABS Color : Light Gray T y pe : NiMH V oltage : 3.
Technical Product Manu al - DCT1900 Product Specifications, Chargers Specs-DCT1900/R8/mw 4-1 © 2000-2005 C HAPTER 4 Chargers 4.1 Chargers for the DT600 4.
Technical Product Manual - DCT 1900 Product Specifications, Chargers 4-2 Specs-DCT1900/R8/mw © 2000-2005 4.1.3 Rapid Desk Charger - BML 162 1001 Environment al T emperature Operating : -40 to 185 ° .
Technical Product Manu al - DCT1900 Product Specifications, Chargers Specs-DCT1900/R8/mw 4-3 © 2000-2005 4.2.2 Desktop Charging Cr adle - BML 162 1 12/04 Environment al T emperature Operating : 23 to.
Technical Product Manual - DCT 1900 Product Specifications, Chargers 4-4 Specs-DCT1900/R8/mw © 2000-2005 4.3 Chargers for the 9p23 4.3.1 9p23 Messenger D esktop Charger - 641303 Dimensions (L x H x D) : 4" x 3" x 2.5" (109 x 76 x 69 mm) Weight : 3.
Technical Product Manu al - DCT1900 Product Specifications, Chargers Specs-DCT1900/R8/mw 4-5 © 2000-2005 4.3.5 9p23 Modular Rack Charge r 4 Slot Charging Module - RC23 Dimensions (L x H x D) : 7" x 7" x 2.
Technical Product Manual - DCT 1900 Product Specifications, Chargers 4-6 Specs-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Product Specifications, Cabinets Specs-DCT1900/R8/mw 5-1 © 2000-2005 C HAPTER 5 Cabinet s 5.1 Modular Cabinet - REX-BAS9021 or BDVNB 101 01/2 or BDVNB 101 01/3 Com.
Technical Product Manual - DCT 1900 Product Specifications, Cabinets 5-2 Specs-DCT1900/R8/mw © 2000-2005 5.4 Synchronization Distributi on Board, SDB -REX-BRD0006 or ROANB 101 38 The SDB is mounted to the Modular Cabinet dur ing syste m installation.
Technical Product Manu al - DCT1900 Product Specifications, System Boards Specs-DCT1900/R8/mw 6-1 © 2000-2005 C HAPTER 6 System Boards 6.1 Digit al T runk Unit (DTU–E1 CAS, CCS) - REX-BRD0002 or 2/.
Technical Product Manual - DCT 1900 Product Specifications, System Boards 6-2 Specs-DCT1900/R8/mw © 2000-2005 6.2 Digit al T runk Unit, DTU- T1, CAS - REX-BRD0021 or 2/ROFNB 157 13/2 Compliance to Regulations and S t andards The DTU–T1 p rovides 2 standard T1 inte rfaces .
Technical Product Manu al - DCT1900 Product Specifications, System Boards Specs-DCT1900/R8/mw 6-3 © 2000-2005 6.4 Central Processing Unit (CPU1) - REX-BRD0004 or 2/ROFNB 157 19/2 Environment al T emp.
Technical Product Manual - DCT 1900 Product Specifications, System Boards 6-4 Specs-DCT1900/R8/mw © 2000-2005 6.6 Speech Link Unit, SLU - REX-BRD0015 or ROFNB 157 16/1 Environment al T emperature Ope.
Technical Product Manu al - DCT1900 Product Specifications, System Boards Specs-DCT1900/R8/mw 6-5 © 2000-2005 6.7 Speech Processing Unit , SPU-S - REX-BRD0017 or ROFNB 157 16/3 Environment al T emper.
Technical Product Manual - DCT 1900 Product Specifications, System Boards 6-6 Specs-DCT1900/R8/mw © 2000-2005 6.9 Cell Link Unit, CL U-S - REX-BRD0016 or ROFNB 157 16/2 Environment al T emperature Op.
Technical Product Manu al - DCT1900 Product Specifications, System Boards Specs-DCT1900/R8/mw 6-7 © 2000-2005 6.10 Line T ermination Unit , L TU - REX-BRD0007 or ROFNB 157 02/06 Compliance to Regulat.
Technical Product Manual - DCT 1900 Product Specifications, System Boards 6-8 Specs-DCT1900/R8/mw © 2000-2005 6.1 1 Line T ermination Un it , L TU2 - REX-BRD0019A Compliance to Regulations and S t an.
Technical Product Manu al - DCT1900 Product Specifications, System Boards Specs-DCT1900/R8/mw 6-9 © 2000-2005 DTMF Dialling The DTMF signals are determined by the comb ination of the output level of L TU and SPU parame ters. Speech Coding S t andard : G .
Technical Product Manual - DCT 1900 Product Specifications, System Boards 6-10 Specs-DCT1900/R8/mw © 2000-2005 6.12 Digit a l Line Un it, DLU - REX-BRD0023 A WS1024 Meridian, A WS1025 Norst ar , A WS1026 Lucent The DLU has 12 analog fr ont ends (ports) that provide 12 di gital line interfaces to the PBX.
Technical Product Manu al - DCT1900 Product Specifications, Firmware (on EPROM) Specs-DCT1900/R8/mw 7-1 © 2000-2005 C HAPTER 7 Firmware (on EPROM) 7.1 CPU DCT1900 Firmware (Mobility) - R YS 105 447 Firmware for CPU REX-BRD0004 or 2/ROFNB 157 19/2 . 7.
Technical Product Manual - DCT 1900 Product Specifications, Firmware (on EPROM) 7-2 Specs-DCT1900/R8/mw © 2000-2005 7.12 L TU Firmware - REX-SW0012 or RYS 105 661 Firmware for REX-BRD0007 or ROFNB 157 02/0 3. 7.13 L TU2 Firmware - REX-L TU2FW01/1H Firmware for REX-BRD0019A or ROFNB 157 25/2.
Technical Product Manu al - DCT1900 Product Specifications , Power Supply Units Specs-DCT1900/R8/mw 8-1 © 2000-2005 C HAPTER 8 Power Supply Unit s 8.1 Modular Power Supply Kit - A WS 1071 (300W) New Length x width x height : 9" x 4.5" x 2" Input voltage : 88 to 132 V AC DC Output : 48V/6.
Technical Product Manual - DCT 1900 Product Specifications, Power Supply Units 8-2 Specs-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Product Specifications, Cables Specs-DCT1900/R8/mw 9-1 © 2000-2005 C HAPTER 9 Cables 9.1 Cables for Modular Cabinet Interconnection Se t - NTMNB 101 105 T o interconnect two adjacent Modular Cabinet s .
Technical Product Manual - DCT 1900 Product Specifications, Cables 9-2 Specs-DCT1900/R8/mw © 2000-2005 DTU-T1/MDF T wisted Pair Ca ble - TRSNB 101 50 (A WS1034) Cable length : 16.
Technical Product Manu al - DCT1900 Product Specifications, Cables Specs-DCT1900/R8/mw 9-3 © 2000-2005 DT620 Port able T elephone Programmin g Cable - KR Y 101 1 135/10 Cable length : 5 ft.
Technical Product Manual - DCT 1900 Product Specifications, Cables 9-4 Specs-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Product Specifications, Software Specs-DCT1900/R8/mw 10- 1 © 2000-2005 C HAPTER 10 Sof tware Note: The following abbreviations are used in this chap ter: CSMW = Cordless System Manager , which now includes the S tatistics package.
Technical Product Manual - DCT 1900 Product Specifications, Software 10-2 Specs-DCT1900/R8/mw © 2000-2005 10.4 Site Survey T ool Configur ation Manager - LZY 213 1 104 For configuration of Port able T elephones for the Site Survey T ool (L TT 601 103) IBM compatible diskette : 3.
Technical Product Manu al - DCT1900 Product Specifications, A ccessories-Portable Telephone Specs-DCT1900/R8/mw 11- 1 © 2000-2005 C HAPTER 11 Accessories-Port a ble T elephone 1 1.
Technical Product Manual - DCT 1900 Product Specifications, Acce ssories-Portable Telep hone 11-2 Specs-DCT1900/R8/mw © 2000-2005 1 1.2 Accessories for the DT620 Batteries High Capacity NiMH Battery .
Technical Product Manu al - DCT1900 Product Specifications, A ccessories-Portable Telephone Specs-DCT1900/R8/mw 11- 3 © 2000-2005 1 1.3 Accessories for the 9p23 Batteries 9p23 Messenger Battery - 643.
Technical Product Manual - DCT 1900 Product Specifications, Acce ssories-Portable Telep hone 11-4 Specs-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Configuration Directions Config-DCT1900/R8/mw © 2000-2005 Section 4 Configuration Directions.
Technical Product Manual - DCT 1900 Configuration Directions Config-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Configuration Directions, Table of Contents Config-DCT1900/R8/mw I © 2000-2005 T able of Contents C HAPTER 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Product Manual - DCT 1900 Configuration Directions, Table of Contents II Config-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Configuration Directions, Introduction Config-DCT1900/R8/mw 1-1 © 2000-2005 C HAPTER 1 Introduction The DCT1900 system was developed as a modular system in order to obt a in maximum flexibility in initial configuration and future growth.
Technical Product Manual - DCT 1900 Configuration Directions, Introduction 1-2 Config-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Configuration Directions, L imitations of the System Config-DCT1900/R8/mw 2-1 © 2000-2005 C HAPTER 2 Limit ations of the System 2.1 Modular Cabinet s Cabinet A system can support up to 4 cabinet s. Each cabinet provid es space for a combination of 9 system boards.
Technical Product Manual - DCT 1900 Configuration Directions, Limitations of the System 2-2 Config-DCT1900/R8/mw © 2000-2005 Synchronization Distribu tion (DCT1900 Mobility Configuration Only) A DCT1.
Technical Product Manu al - DCT1900 Configuration Directions, L imitations of the System Config-DCT1900/R8/mw 2-3 © 2000-2005 2.2 Modular Cabinet Powering Restrictions Although the Modular Cabine t has sp ace for 9 boar ds, not all board comb inations are allowed due to power limitations of the DC/DC converter on the backplane.
Technical Product Manual - DCT 1900 Configuration Directions, Limitations of the System 2-4 Config-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Configuration Directions, Base Station Planning Config-DCT1900/R8/mw 3-1 © 2000-2005 C HAPTER 3 Base St ation Planning The major t ask in configuring a DCT1900 syste m is defining the numbe r of Base S tations required to cover an area to a satisfacto ry level.
Technical Product Manual - DCT 1900 Configuration Directions, Base Station Planning 3-2 Config-DCT1900/R8/mw © 2000-2005 z X–ray rooms in hospit als protected by lead walls, computer rooms in banking buildings protected against unwanted inte rference, et c.
Technical Product Manu al - DCT1900 Configuration Directions, Base Station Planning Config-DCT1900/R8/mw 3-3 © 2000-2005 3.6 Site Survey T o satisfy area coverage and traf fic deman ds, the si te must be surveyed in order to determine the number and position of Base S tations.
Technical Product Manual - DCT 1900 Configuration Directions, Base Station Planning 3-4 Config-DCT1900/R8/mw © 2000-2005 4. Measure horizont al range on floor belo w , see Figur e 3– 2, (3). Go to the floor below , leaving the Base S t ation on its cur re nt location and measure the horizontal cover ag e again.
Technical Product Manu al - DCT1900 Configuration Directions, Base Station Planning Config-DCT1900/R8/mw 3-5 © 2000-2005 Fig. 3–3 Antenna Pattern 6.
Technical Product Manual - DCT 1900 Configuration Directions, Base Station Planning 3-6 Config-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Configuration Directions, Base Station Powering Config-DCT1900/R8/mw 4-1 © 2000-2005 C HAPTER 4 Base S t ation Powering 4.1 General After a Base S tation plan has been ma de (see Chapter 3), it must be estab lished which powering method is more su itable to p ower the Base S tations.
Technical Product Manual - DCT 1900 Configuration Directions, Base Station Powering 4-2 Config-DCT1900/R8/mw © 2000-2005 Fig. 4–1 Powering Base S tations by a remote Supply 4.
Technical Product Manu al - DCT1900 Configuration Directions, Base Station Powering Config-DCT1900/R8/mw 4-3 © 2000-2005 Note: When using the PBX option refer to the PBX supplier and/or PBX documentation to assure that the PBX power supply matches the wo rst case power re quirements of the DCT1900 system.
Technical Product Manual - DCT 1900 Configuration Directions, Base Station Powering 4-4 Config-DCT1900/R8/mw © 2000-2005 where: n = number of twisted pairs (when using data pairs only: n=2) U = power supply voltage P Base = worst case power consumption of Base S tation = 7.
Technical Product Manu al - DCT1900 Configuration Directions, Base Station Powering Config-DCT1900/R8/mw 4-5 © 2000-2005 The following resistan ce values for the twisted pa irs are used: z 26 A WG wire cable : .082 /ft. z 24 A WG wire cable : .055 /ft.
Technical Product Manual - DCT 1900 Configuration Directions, Base Station Powering 4-6 Config-DCT1900/R8/mw © 2000-2005 T able 4–3 Power Consumption (W att s) of Base S t ations and Cabling when Powered with 42V 26 AWG ( 0.4 mm) wire s ize ( ∅ ) 24 AWG (0.
Technical Product Manu al - DCT1900 Configuration Directions, Base Station Powering Config-DCT1900/R8/mw 4-7 © 2000-2005 T able 4–4 Power Consumption (W att s) of Base S t ations and Cabling when Powered with 48V 26 AW G (0.4 mm ) wir e siz e ( ∅ ) 24 AWG (0.
Technical Product Manual - DCT 1900 Configuration Directions, Base Station Powering 4-8 Config-DCT1900/R8/mw © 2000-2005 4.5 Alternative for Calculating the Po wer Consumption per Base St ation In Figure 4–4 the power con su mption of the Base S t ation and the cabling is given as a funct ion of the cable length in terms of pe rcentage.
Technical Product Manu al - DCT1900 Configuration Directions, Base Station Powering Config-DCT1900/R8/mw 4-9 © 2000-2005 T able 4–5 Power Consumption Related to Cable Length Relative lengt h x (in %) Total power consumpt i on (Watt) 07 . 5 57 . 7 10 7.
Technical Product Manual - DCT 1900 Configuration Directions, Base Station Powering 4-10 Config-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Configuration Directions, Traffic Capacity of the System Config-DCT1900/R8/mw/ 5-1 © 2000-2005 C HAPTER 5 T raffic Cap acity of the System The traffic cap acity of the DCT1900 system is ma inly determined by the RE and in exceptional cases also by the Base S tations.
Technical Product Manual - DCT 1900 Configuration Directions, Traffic Capacity of the System 5-2 Config-DCT1900/R8/mw © 2000-2005 As a RE can handle only as many simulta neous ca lls as the number of.
Technical Product Manu al - DCT1900 Configuration Directions, Traffic Capacity of the System Config-DCT1900/R8/mw/ 5-3 © 2000-2005 load on the Base S tation close by . It may be necessary to add a Base S tation in this area to have enough capacity for others to call as well.
Technical Product Manual - DCT 1900 Configuration Directions, Traffic Capacity of the System 5-4 Config-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Configuration Directions, Relation bet ween Parts Config-DCT1900/R8/mw 6-1 © 2000-2005 C HAPTER 6 Relation between Part s Radio Exchange It em Connects Rem arks Modular Cabinet 9 System Boards 1 Connection Boar d 2 Powe r Sup pl ie s Number of Syst em Boards may be less due to power l imita tions.
Technical Product Manual - DCT 1900 Configuration Directions, Relation between Parts 6-2 Config-DCT1900/R8/mw © 2000-2005 Power Supplies Cables Items M odular Cabinet Connects Remarks Power Supply Unit Mains t o Modular Cabi net. Powers s yst em boards and a maximum of 24 Base Stations.
Technical Product Manu al - DCT1900 Installation Instructions Install-DCT1900/R8/mw © 2000-2005 Section 5 Inst allation Instructions.
Technical Product Manual - DCT 1900 Installation Instructions Install-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Installation Instructions, Table of Contents Install-DCT1900/R8/mw I © 2000-2005 T able of Contents C HAPTER 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Product Manual - DCT 1900 Installation Instructions, Table of Contents II Install-DCT1900/R8/mw © 2000-2005 4.11 Interconnecting Modular Cabinets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12 4.
Technical Product Manu al - DCT1900 Installation Instructions, Table of Contents Install-DCT1900/R8/mw III © 2000-2005 C HAPTER 11 Digital Trunk Unit (DTU–E1) – REX-BRD0002 or 2/RO FNB 157 13/1 . . . . . . . . . . 11-1 11.1 General . . . . . . . .
Technical Product Manual - DCT 1900 Installation Instructions, Table of Contents IV Install-DCT1900/R8/mw © 2000-2005 16.6.6.1 Wall Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Product Manu al - DCT1900 Installation Instructions, Table of Contents Install-DCT1900/R8/mw V © 2000-2005 22.3 Installation - DTU-T1 (CAS or CCS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2-3 C HAPTER 23 Modular Cabinet – LTU Cablin g .
Technical Product Manual - DCT 1900 Installation Instructions, Table of Contents VI Install-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Installation Instructions, Introduction Install-DCT1900/R8/mw 1-1 © 2000-2005 C HAPTER 1 Introduction This section describes ho w to install the DCT1900 system.
Technical Product Manual - DCT 1900 Installation Instructions, Introduction 1-2 Install-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Installation Instructions, General Install-DCT1900/R8/mw 2-1 © 2000-2005 C HAPTER 2 General 2.1 Environment al Requirement s The building (rooms) in which the RE and Base S tations are to be insta lled mu st comply with the following: z The air shall be free from dust and smoke.
Technical Product Manual - DCT 1900 Installation Instructions, General 2-2 Install-DCT1900/R8/mw © 2000-2005 z equipment to measure the de lay times of Base S tation cables an d external synchro nization cables-TDR z Siemens 66 block z punch down tool 2.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – Installation Steps Install-DCT1900/R8/mw 3-1 © 2000-2005 C HAPTER 3 Modular Cabinet – Inst allation S tep s 3.1 Introduction Paragraph 3.2 describe s the recommended board positio ns.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – Installation Steps 3-2 Install-DCT1900/R8/mw © 2000-2005 CLUs/SLUs CLUs and SLUs are p laced on the r ight han d side of the ca binet. In this position CLU/MDF cables do not influence the a ccessibility of the MCCB.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – Installation Steps Install-DCT1900/R8/mw 3-3 © 2000-2005 15. Initialize the DCT1900 system. See "C SM Installer ’ s Quick Guide (Appendix I) 16. Place the securing bar .
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – Installation Steps 3-4 Install-DCT1900/R8/mw © 2000-2005 Note: The board position lab el should not b e placed on th e le ading edge at the top of the cabinet for this will isolate the enclosure EMI shielding.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – Installation Steps Install-DCT1900/R8/mw 3-5 © 2000-2005 Fig. 3–3 Connector Positions and Examples of Cable Labell.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – Installation Steps 3-6 Install-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabi net – REX-BAS9021 or BDVNB 1 01 01/2 Install-DCT1900/R8/mw 4-1 © 2000-2005 C HAPTER 4 Modular Cabinet – REX-BAS9021 or BDVNB 101 01/2 or BDVNB 101 01/3 4.
Technical Product Manual - DCT 1900 Installation Instructions, or BDVNB 101 01/3 4-2 Install-DCT1900/R8/mw © 2000-2005 4.3 Inst allation Area for the Modular Cabinet(s) z Do not mount the cabinet to drywall using plas tic drywall plugs.
Technical Product Manu al - DCT1900 Installation Instructions, or BDVNB 101 01/3 Install-DCT1900/R8/mw 4-3 © 2000-2005 Fig. 4-1 Installation of the Modula r Cabinet(s) Cabinet 1 (Cabinet 3) Cabinet 2 (Cabinet 1) C abinet 4 (Cabinet 2) Cabinet 3 (Cabinet 4) 1/8 in x d x 1/4 in 8 7/8 in Approx.
Technical Product Manual - DCT 1900 Installation Instructions, or BDVNB 101 01/3 4-4 Install-DCT1900/R8/mw © 2000-2005 4.4 Part s of the Modular Cabinet Figure 4–2 shows a drawing of the Mod ular Cabinet and its most import ant p arts.
Technical Product Manu al - DCT1900 Installation Instructions, or BDVNB 101 01/3 Install-DCT1900/R8/mw 4-5 © 2000-2005 Fig. 4-3 Modular Cabinet( REX- BAS9021) Power Switch Assembly Left Side V iew Fr.
Technical Product Manual - DCT 1900 Installation Instructions, or BDVNB 101 01/3 4-6 Install-DCT1900/R8/mw © 2000-2005 4.5 Pre–mounting of a Modular Ca binet in a One Cabinet System 1. Refer to p aragrah 4 .4. 2. Remove the front cover of the cabinet ( see Figure 4–4): - Remove the screws that secure the cover (1).
Technical Product Manu al - DCT1900 Installation Instructions, or BDVNB 101 01/3 Install-DCT1900/R8/mw 4-7 © 2000-2005 4.6 Pre–mounting of Modu lar Cabinet s in a Multi Cabinet System When a system consists of two to four Modula r Cabinets, the Modular Cabinet s have to be interconnected using an interconnection set for th e Modular Cabine t.
Technical Product Manual - DCT 1900 Installation Instructions, or BDVNB 101 01/3 4-8 Install-DCT1900/R8/mw © 2000-2005 Fig. 4–5 Placement of the Shielding Gaskets Fig.
Technical Product Manu al - DCT1900 Installation Instructions, or BDVNB 101 01/3 Install-DCT1900/R8/mw 4-9 © 2000-2005 z Sync port i nst allation se t: NTMNB 101 107 -S D B - T wo spacers - T wo spring washers z T orx screwdriver nr . 20 Follow the next step s for mounting the SDB: 1.
Technical Product Manual - DCT 1900 Installation Instructions, or BDVNB 101 01/3 4-10 Install-DCT1900/R8/mw © 2000-2005 4.9 Connection to Protective Ground The Modular Cabinet must always be connec ted to PBX ground or protective ground.
Technical Product Manu al - DCT1900 Installation Instructions, or BDVNB 101 01/3 Install-DCT1900/R8/mw 4-1 1 © 2000-2005 4.10 Connection of Wr ist S trap for ESD After mounting th e Modular Cabine t(s), the installer has t o protect against damaging system boards by ESD.
Technical Product Manual - DCT 1900 Installation Instructions, or BDVNB 101 01/3 4-12 Install-DCT1900/R8/mw © 2000-2005 Fig. 4-10 Backplane of Modular Cabinet 4.
Technical Product Manu al - DCT1900 Installation Instructions, or BDVNB 101 01/3 Install-DCT1900/R8/mw 4-1 3 © 2000-2005 Procedure 1.If the system boards are already in stalled, temporarily remove the boards that block access to the R–network s. Note: Follow paragraph 4.
Technical Product Manual - DCT 1900 Installation Instructions, or BDVNB 101 01/3 4-14 Install-DCT1900/R8/mw © 2000-2005 z Any cabinet needs to have a minimum of two cir cui t boards installed in it for the power supply to operate correctly .
Technical Product Manu al - DCT1900 Installation Instructions, or BDVNB 101 01/3 Install-DCT1900/R8/mw 4-1 5 © 2000-2005 The actual opera tion of addin g a cabine t t a kes pl ace in two step s, before the sched uled do wntim e and during the sch edu led downtime.
Technical Product Manual - DCT 1900 Installation Instructions, or BDVNB 101 01/3 4-16 Install-DCT1900/R8/mw © 2000-2005 z Insert a circuit board into the cabi net in any slot. T urn the cabinet po wer switch on. If everything is all right, then a green L ED at the very top of the circuit board should be lit.
Technical Product Manu al - DCT1900 Installation Instructions, or BDVNB 101 01/3 Install-DCT1900/R8/mw 4-1 7 © 2000-2005 z Remove any circuit boards in the three slots ne xt to the side of t he existing cabinet that is going up against the new cabinet.
Technical Product Manual - DCT 1900 Installation Instructions, or BDVNB 101 01/3 4-18 Install-DCT1900/R8/mw © 2000-2005 T esting and back up z V erify that all existing port ables are working.
Technical Product Manu al - DCT1900 Installation Instructions, Central Processing Unit (C PU) – REX-BRD0004 or 2/ROFNB 157 19/2 Install-DCT1900/R8/mw 5-1 © 2000-2005 C HAPTER 5 Central Processing Unit (CPU) – REX-BRD0004 or 2/ROFNB 157 19/2 5.
Technical Product Manual - DCT 1900 Installation Instructions, Central Processing Unit (CPU) – REX-BRD0004 o r 2/ROFNB 157 19/2 5-2 Install-DCT1900/R8/mw © 2000-2005 Fig.
Technical Product Manu al - DCT1900 Installation Instructions, Central Processing Unit (C PU) – REX-BRD0004 or 2/ROFNB 157 19/2 Install-DCT1900/R8/mw 5-3 © 2000-2005 Fig.
Technical Product Manual - DCT 1900 Installation Instructions, Central Processing Unit (CPU) – REX-BRD0004 o r 2/ROFNB 157 19/2 5-4 Install-DCT1900/R8/mw © 2000-2005 Connectors The CPU has the foll.
Technical Product Manu al - DCT1900 Installation Instructions, Central Processing Unit (C PU) – REX-BRD0004 or 2/ROFNB 157 19/2 Install-DCT1900/R8/mw 5-5 © 2000-2005 5.3 Inst allation For the inst a llation of the CPU board refer to Figure 5–4 and pe rform the followi ng steps: 1.
Technical Product Manual - DCT 1900 Installation Instructions, Central Processing Unit (CPU) – REX-BRD0004 o r 2/ROFNB 157 19/2 5-6 Install-DCT1900/R8/mw © 2000-2005 Fig.
Technical Product Manu al - DCT1900 Installation Instructions, Central Processing Unit (C PU) – REX-BRD0004 or 2/ROFNB 157 19/2 Install-DCT1900/R8/mw 5-7 © 2000-2005 Fig. 5-4 CPU-REX-BRD0004 or 2/ROFNB 157 19/2 cont. Reset butt on Sync out Pri nter /SMS RS232-A General A lar m port #1 EMPTY Lithiu m ba ttery (type DL2032) LED1 .
Technical Product Manual - DCT 1900 Installation Instructions, Central Processing Unit (CPU) – REX-BRD0004 o r 2/ROFNB 157 19/2 5-8 Install-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Product Specifications, System Boards Specs-DCT1900/R8/mw 6-1 © 2000-2005 C HAPTER 6 System Boards 6.1 Digit al T runk Unit (DTU–E1 CAS, CCS) - REX-BRD0002 or 2/.
Technical Product Manual - DCT 1900 Product Specifications, System Boards 6-2 Specs-DCT1900/R8/mw © 2000-2005 6.2 Digit al T runk Unit, DTU- T1, CAS - REX-BRD0021 or 2/ROFNB 157 13/2 Compliance to Regulations and S t andards The DTU–T1 p rovides 2 standard T1 inte rfaces .
Technical Product Manu al - DCT1900 Product Specifications, System Boards Specs-DCT1900/R8/mw 6-3 © 2000-2005 6.4 Central Processing Unit (CPU1) - REX-BRD0004 or 2/ROFNB 157 19/2 Environment al T emp.
Technical Product Manual - DCT 1900 Product Specifications, System Boards 6-4 Specs-DCT1900/R8/mw © 2000-2005 6.6 Speech Link Unit, SLU - REX-BRD0015 or ROFNB 157 16/1 Environment al T emperature Ope.
Technical Product Manu al - DCT1900 Product Specifications, System Boards Specs-DCT1900/R8/mw 6-5 © 2000-2005 6.7 Speech Processing Unit , SPU-S - REX-BRD0017 or ROFNB 157 16/3 Environment al T emper.
Technical Product Manual - DCT 1900 Product Specifications, System Boards 6-6 Specs-DCT1900/R8/mw © 2000-2005 6.9 Cell Link Unit, CL U-S - REX-BRD0016 or ROFNB 157 16/2 Environment al T emperature Op.
Technical Product Manu al - DCT1900 Product Specifications, System Boards Specs-DCT1900/R8/mw 6-7 © 2000-2005 6.10 Line T ermination Unit , L TU - REX-BRD0007 or ROFNB 157 02/06 Compliance to Regulat.
Technical Product Manual - DCT 1900 Product Specifications, System Boards 6-8 Specs-DCT1900/R8/mw © 2000-2005 6.1 1 Line T ermination Un it , L TU2 - REX-BRD0019A Compliance to Regulations and S t an.
Technical Product Manu al - DCT1900 Product Specifications, System Boards Specs-DCT1900/R8/mw 6-9 © 2000-2005 DTMF Dialling The DTMF signals are determined by the comb ination of the output level of L TU and SPU parame ters. Speech Coding S t andard : G .
Technical Product Manual - DCT 1900 Product Specifications, System Boards 6-10 Specs-DCT1900/R8/mw © 2000-2005 6.12 Digit al Line Un it, DLU - REX-BRD0023 A WS1024 Meridian, A WS1025 Norst ar , A WS1026 Lucent The DLU has 12 analog fr ont ends (ports) that provide 12 di gital line interfaces to the PBX.
Technical Product Manu al - DCT1900 Installation Instructions, Cell Link Unit (CL U) – REX-BRD0014 or ROFNB 157 11/2 Install-DCT1900/R8/mw 7-1 © 2000-2005 C HAPTER 7 Cell Link Unit (CLU ) – REX-BRD0014 or ROFNB 157 1 1 /2 7.1 General The CLU is used to control up to 8 Base S tations via twisted p air cables with a m aximum length of 2.
Technical Product Manual - DCT 1900 Installation Instructions, Cell Link Unit (CLU) – REX-BRD0 014 or ROFNB 157 11/2 7-2 Install-DCT1900/R8/mw © 2000-2005 Fig.
Technical Product Manu al - DCT1900 Installation Instructions, Cell Link Unit (CL U) – REX-BRD0014 or ROFNB 157 11/2 Install-DCT1900/R8/mw 7-3 © 2000-2005 Fig. 7–2 Po wer Distribution on t he CLU 7.3 Inst allation 1. Insert the CLU into the card guid es in the specified slot position.
Technical Product Manual - DCT 1900 Installation Instructions, Cell Link Unit (CLU) – REX-BRD0 014 or ROFNB 157 11/2 7-4 Install-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Installation Instructions, Cell Link Un it (CLU-S) –REX-BRD0016 or ROFN B 157 16/2 Install-DCT1900/R8/mw 8-1 © 2000-2005 C HAPTER 8 Cell Link Unit (CLU -S) –REX-BRD0016 or ROFNB 157 16/2 8.1 General The CLU-S is used to co ntro l up to 8 Ba se S tatio ns via twisted pair cabl es with a maximum length of 1.
Technical Product Manual - DCT 1900 Installation Instructions, Cell Link Unit (CLU-S) –REX-BRD 0016 or ROFNB 157 16/2 8-2 Install-DCT1900/R8/mw © 2000-2005 Fig.
Technical Product Manu al - DCT1900 Installation Instructions, Cell Link Un it (CLU-S) –REX-BRD0016 or ROFN B 157 16/2 Install-DCT1900/R8/mw 8-3 © 2000-2005 Fig. 8–2 Power Distribution on the CLU-S 8.3 Inst allation 1. Insert the CLU-S into the card gui des in the specified boar d position.
Technical Product Manual - DCT 1900 Installation Instructions, Cell Link Unit (CLU-S) –REX-BRD 0016 or ROFNB 157 16/2 8-4 Install-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Installation Instructions, Speech Link Un it (SLU) – REX-BRD0015 o r ROFNB 157 16/1 Install-DCT1900/R8/mw 9-1 © 2000-2005 C HAPTER 9 S peech Link Unit (SLU) – REX-BRD0015 or ROFNB 157 16/1 9.1 General The SLU is a com bination of an SPU and a CLU on on e boar d.
Technical Product Manual - DCT 1900 Installation Instructions, Speech Link Unit (SLU) – REX-BRD0015 or ROFNB 157 16/1 9-2 Install-DCT1900/R8/mw © 2000-2005 Fig.
Technical Product Manu al - DCT1900 Installation Instructions, Speech Link Un it (SLU) – REX-BRD0015 o r ROFNB 157 16/1 Install-DCT1900/R8/mw 9-3 © 2000-2005 Fig. 9–2 Base S t ation Power Distribution on the SLU 9.3 Inst allation 1. Insert the SLU into the card guide in the specified boar d position.
Technical Product Manual - DCT 1900 Installation Instructions, Speech Link Unit (SLU) – REX-BRD0015 or ROFNB 157 16/1 9-4 Install-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Installation Instructions, Speech Processing Unit (SPU–S) – REX-BRD0017 or ROFN B 157 16/3 Install-DCT1900/R8/mw 10- 1 © 2000-2005 C HAPTER 10 S peech Processing Unit (SPU–S) – REX-BRD0017 or ROFNB 157 16/3 10.
Technical Product Manual - DCT 1900 Installation Instructions, Speech Processing Unit ( SPU–S) – REX-BRD0017 or ROFNB 157 16/3 10-2 Install-DCT1900/R8/mw © 2000-2005 Fig.
Technical Product Manu al - DCT1900 Installation Instructions, Digital Trunk Unit (DTU –E1) – REX-BRD0002 or 2/ROFNB 157 13/1 Install-DCT1900/R8/mw 11- 1 © 2000-2005 C HAPTER 11 Digit al T runk Unit (DTU–E1) – REX-BRD0002 or 2/ROFNB 157 13/1 11 .
Technical Product Manual - DCT 1900 Installation Instructions, Digital Trunk Unit (DTU –E1) – REX-BRD0002 or 2/ROFNB 157 13/1 11-2 Install-DCT1900/R8/mw © 2000-2005 LEDs Each DTC has it s own LEDs: LED1 Green : Normally on. Power On LED LED2 Red : Normally off.
Technical Product Manu al - DCT1900 Installation Instructions, Digital Trunk Unit (DTU –E1) – REX-BRD0002 or 2/ROFNB 157 13/1 Install-DCT1900/R8/mw 11- 3 © 2000-2005 Fig.
Technical Product Manual - DCT 1900 Installation Instructions, Digital Trunk Unit (DTU –E1) – REX-BRD0002 or 2/ROFNB 157 13/1 11-4 Install-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Installation Instructions, Digital Trunk Unit (DTU-T1, CAS) - REX-BRD0021 or 2/ROFNB 157 13/2 Install-DCT1900/R8/mw 12- 1 © 2000-2005 C HAPTER 12 Digit al T runk Unit (DTU-T 1, CAS) - REX-BRD0021 or 2/ROFNB 157 13/2 12.
Technical Product Manual - DCT 1900 Installation Instructions, Digital Trunk Unit ( DTU-T1, CAS) - REX-BRD0021 or 2/ROFNB 157 13/2 12-2 Install-DCT1900/R8/mw © 2000-2005 T able 12–1 Setting of the Jumpers Cable length (Ft.
Technical Product Manu al - DCT1900 Installation Instructions, Digital Trunk Unit (DTU-T1, CAS) - REX-BRD0021 or 2/ROFNB 157 13/2 Install-DCT1900/R8/mw 12- 3 © 2000-2005 Fig.
Technical Product Manual - DCT 1900 Installation Instructions, Digital Trunk Unit ( DTU-T1, CAS) - REX-BRD0021 or 2/ROFNB 157 13/2 12-4 Install-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Installation Instructions, Digital Trunk Unit (DTU-T1, CCS) - REX- BRD0025 or 2/ROFNB 157 13/3 Install-DCT1900/R8/mw 13- 1 © 2000-2005 C HAPTER 13 Digit al T runk Unit (DTU-T 1, CCS) - REX-BRD0025 or 2/ROFNB 157 13/3 13.
Technical Product Manual - DCT 1900 Installation Instructions, Digital Trunk Unit ( DTU-T1, CCS) - REX-BRD0025 or 2/ROFNB 157 13/3 13-2 Install-DCT1900/R8/mw © 2000-2005 T able 13–1 Setting of the Jumpers Cable length (Ft.
Technical Product Manu al - DCT1900 Installation Instructions, Digital Trunk Unit (DTU-T1, CCS) - REX- BRD0025 or 2/ROFNB 157 13/3 Install-DCT1900/R8/mw 13- 3 © 2000-2005 Fig.
Technical Product Manual - DCT 1900 Installation Instructions, Digital Trunk Unit ( DTU-T1, CCS) - REX-BRD0025 or 2/ROFNB 157 13/3 13-4 Install-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Installation Instructions, Line Termination Unit (LTU) – R EX-BRD0007 or ROFNB 157 02/6 and LTU2 - REX-BRD0019A or ROFNB Install-DCT1900/R8/mw 14- 1 © 2000-2005 C HAPTER 14 Line T ermination Unit (L TU) – REX-BRD0007 or ROFNB 157 02/6 and L T U2 - REX-BRD0019A or ROFNB 157 25/2 14.
Technical Product Manual - DCT 1900 Installation Instructions, Line Termination Unit ( LTU) – R EX-BRD0007 or ROFNB 157 02/6 and LTU2 - REX-BRD0019A or ROFNB 14-2 Install-DCT1900/R8/mw © 2000-2005 Fig.
Technical Product Manu al - DCT1900 Installation Instructions, Digital Line Unit (DLU) - REX-BR D0023 Install-DCT1900/R8/mw 15- 1 © 2000-2005 C HAPTER 15 Digit al Line Unit (DLU) - REX-BRD0023 A WS1024 Meridian, A WS1025 Norst ar , A WS1026 Lucent 15.
Technical Product Manual - DCT 1900 Installation Instructions, AWS1024 Meri dian, AWS1025 Norstar, AWS1026 Lucent 15-2 Install-DCT1900/R8/mw © 2000-2005 15.3 Inst allation 1. Insert the DLU on to the card guide in the selected bo ard position. 2. Gently push the board into the backplane conne ctor until it locks.
Technical Product Manu al - DCT1900 Installation Instructions, AWS1024 Me ridian, AWS1025 Norstar, AWS1026 Lucent Install-DCT1900/R8/mw 15- 3 © 2000-2005 <FPGA>.mcs V ersion Download Procedure 1. At the DLU> prompt in the terminal window , press df and return .
Technical Product Manual - DCT 1900 Installation Instructions, AWS1024 Meri dian, AWS1025 Norstar, AWS1026 Lucent 15-4 Install-DCT1900/R8/mw © 2000-2005 Fig.
Technical Product Manu al - DCT1900 Installation Instructions, Base Station – KRC 101 1371 Install-DCT1900/R8/mw 16- 1 © 2000-2005 C HAPTER 16 Base St ation – KRC 101 1371 **T o order a complete Base St atio n, use Part Number: DB600-001** 16.
Technical Product Manual - DCT 1900 Installation Instructions, Base Station – KRC 101 1371 16-2 Install-DCT1900/R8/mw © 2000-2005 LEDs (Fig. 16-1) LED1 Power LED Green : Base S tation powered LED2 .
Technical Product Manu al - DCT1900 Installation Instructions, Base Station – KRC 101 1371 Install-DCT1900/R8/mw 16- 3 © 2000-2005 Fig. 16-1 Base S t ation Cover and Back 16.2 Base St ation Cabling Each Base S t ation requires a minimum of 2 p airs of CA T3 unshielded twisted p air cable.
Technical Product Manual - DCT 1900 Installation Instructions, Base Station – KRC 101 1371 16-4 Install-DCT1900/R8/mw © 2000-2005 The cable set, NTM/TSRNB 101 29, that conne cts the CLU/SLU to the MDF br ings out the three pairs mentioned above: SC0 , SC1, and EPP .
Technical Product Manu al - DCT1900 Installation Instructions, Base Station – KRC 101 1371 Install-DCT1900/R8/mw 16- 5 © 2000-2005 Correct imp lementation of the autom atic delay measurement requires that th e ba se station be connected to the Radio Exchange and powered when adding the base station using the CSMW software.
Technical Product Manual - DCT 1900 Installation Instructions, Base Station – KRC 101 1371 16-6 Install-DCT1900/R8/mw © 2000-2005 5. Enter the measur ed de lay value in to the co rrect column on th.
Technical Product Manu al - DCT1900 Installation Instructions, Base Station – KRC 101 1371 Install-DCT1900/R8/mw 16- 7 © 2000-2005 Fig. 16–2 Connector Pinning Note: After completion of the installation , Base S tations must be added u sing the CSMW “Installer Quick Guide”.
Technical Product Manual - DCT 1900 Installation Instructions, Base Station – KRC 101 1371 16-8 Install-DCT1900/R8/mw © 2000-2005 Fig. 16-3 Cut Mounting Clip 2. Adhere plastic spacer to the mo u nt ing clip. Fig. 16-4 Mounting Clip with Plastic S p acer 3.
Technical Product Manu al - DCT1900 Installation Instructions, Base Station – KRC 101 1371 Install-DCT1900/R8/mw 16- 9 © 2000-2005 4. Assemble the ceiling clips to the bracket. Fig. 16-6 Attaching Ceili ng Clips to the Ceiling Bracket a. T w ist ceiling clip clockwise into the bracket until it bottoms out on the bracket.
Technical Product Manual - DCT 1900 Installation Instructions, Base Station – KRC 101 1371 16-10 Install-DCT1900/R8/mw © 2000-2005 6. Screw in the two 1/4-20 screws with the captured st ar washers as shown. Check that the assembly is locked to the base sta tion.
Technical Product Manu al - DCT1900 Installation Instructions, Base Station – KRC 101 1371 Install-DCT1900/R8/mw 16-11 © 2000-2005 Mounting T echnique Fig. 16-10 Mounting to Factory Ceiling The chain is to be used as two continuous pieces . Loop the chains around the I Beam and connect them to the screw eyes with the Quick Links.
Technical Product Manual - DCT 1900 Installation Instructions, Base Station – KRC 101 1371 16-12 Install-DCT1900/R8/mw © 2000-2005 Fig. 16-1 1 Mo u nting Location s 16.
Technical Product Manu al - DCT1900 Installation Instructions, Base Station – KRC 101 1371 Install-DCT1900/R8/mw 16-13 © 2000-2005 locations where co verage area and ran ge need to be optimized, it.
Technical Product Manual - DCT 1900 Installation Instructions, Base Station – KRC 101 1371 16-14 Install-DCT1900/R8/mw © 2000-2005 Note that mounting fasteners dif fer accord ing to the bu ilding surface being mounted to . When mounting to wood surfac es, standard 3/8" "lag bolt s" are to be used.
Technical Product Manu al - DCT1900 Installation Instructions, Base Station – KRC 101 1371 Install-DCT1900/R8/mw 16-15 © 2000-2005 Caution: Mounting Arms of 12" and 1 8" are provided .
Technical Product Manual - DCT 1900 Installation Instructions, Base Station – KRC 101 1371 16-16 Install-DCT1900/R8/mw © 2000-2005 Fig. 16-14 Mounting Pla te Attach men t to Housing Fig. 16-15 Mounting Arm 3.0" 5.0" Locate Small Pattern Mounting Plate where shown and drill .
Technical Product Manu al - DCT1900 Installation Instructions, Base Station – KRC 101 1371 Install-DCT1900/R8/mw 16-17 © 2000-2005 Fig. 16-16 Mounting Pla te (Small Pattern) 1.50 0.50 2.50 4.50 5.00 3.50 .437 D 4 places wel d tubi ng full circumference to pla te 2 plac es.
Technical Product Manual - DCT 1900 Installation Instructions, Base Station – KRC 101 1371 16-18 Install-DCT1900/R8/mw © 2000-2005 Fig. 16-17 Mounting Plate (Large Pattern) 4.00 .437 D 8 places 1.00 2.00 4.00 6.00 7.00 8.00 weld tubing full circumference to plate 2 places.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabi net Connection Board (MC CB) - ROANB 101 28 Install-DCT1900/R8/mw 17- 1 © 2000-2005 C HAPTER 17 Modular Cabinet Connection Board (MCCB) - ROANB 101 28 17.1 Board Description The MCCB (see Fig.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet Connection Boar d (MCCB) - ROANB 101 28 17-2 Install-DCT1900/R8/mw © 2000-2005 Fig. 17–1 Power D istribution on the MCCB Fuses The MCCB is provided with two fast 15A fuses (see Fig.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabi net Connection Board (MC CB) - ROANB 101 28 Install-DCT1900/R8/mw 17- 3 © 2000-2005 Fig. 17–2 DTU Coax Cable Ground S trap Settings on MCCB DTC In/Out Connectors There are two rows of connectors for connection of the DTU-E1 coaxial cables.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet Connection Boar d (MCCB) - ROANB 101 28 17-4 Install-DCT1900/R8/mw © 2000-2005 Connectors Ground bridge : For connecting the plus pole of PW–EXT to ground.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabi net Connection Board (MC CB) - ROANB 101 28 Install-DCT1900/R8/mw 17- 5 © 2000-2005 Fig.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet Connection Boar d (MCCB) - ROANB 101 28 17-6 Install-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Installation Instructions, Sync hr onization Distribution Board (SDB) – REX-BRD0006 or ROANB 101 38 Install-DCT1900/R8/mw 18- 1 © 2000-2005 C HAPTER 18 Synchronization Distributi on Board (SDB) – REX-BRD0006 or ROANB 101 38 18.
Technical Product Manual - DCT 1900 Installation Instructions, Synchronization Distri bution Board (SDB) – REX-BRD0006 or ROANB 101 38 18-2 Install-DCT1900/R8/mw © 2000-2005 Fig.
Technical Product Manu al - DCT1900 Installation Instructions, Sync hr onization Distribution Board (SDB) – REX-BRD0006 or ROANB 101 38 Install-DCT1900/R8/mw 18- 3 © 2000-2005 External Sync Cable (TSR 951 284) Cable length : 20 ft.
Technical Product Manual - DCT 1900 Installation Instructions, Synchronization Distri bution Board (SDB) – REX-BRD0006 or ROANB 101 38 18-4 Install-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – Power Cabling Install-DCT1900/R8/mw 19- 1 © 2000-2005 C HAPTER 19 Modular Cabinet – Power Cabling 19.1 Introd uction This chapter describes the in st allation of the powe r cables in two di f ferent ve rsion s of the Mod ula r Cabinet.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – Power Cablin g 19-2 Install-DCT1900/R8/mw © 2000-2005 Factory Fitted Po wer Cabling The Modular Cabinet is delivered with the following powering cables fitted: z Cable TRENB 101 02 (#1902 48) between the filter and the fu se holders (see Fig.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – Power Cabling Install-DCT1900/R8/mw 19- 3 © 2000-2005 Fig. 19–3 Power Connections to T op of Filter Fig.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – Power Cablin g 19-4 Install-DCT1900/R8/mw © 2000-2005 19.3 Installation Modular Cabinet Powered by an Externa l 300 .
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – Power Cabling Install-DCT1900/R8/mw 19- 5 © 2000-2005 C L U / S L U C L U / S L U C L U / S L U Bac k Pl an e A B MC.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – Power Cablin g 19-6 Install-DCT1900/R8/mw © 2000-2005 Base St ation Power Supplied to a Maximum of 7 CLUs/SLUs via the PW–EXT Input on th e MCCB This requires a power supply with a capacity greater than 3 00W , such as a PBX powe r supply .
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – Power Cabling Install-DCT1900/R8/mw 19- 7 © 2000-2005 Fig. 19–8 Cable Diagram of Po wering the Mo dula r Cabinet a.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – Power Cablin g 19-8 Install-DCT1900/R8/mw © 2000-2005 19.4 Modular Cabinet - REX-BAS9021A/1B Figure 19–9 shows the power distribution in a Modular Cabinet powered by exte rnal -48Vdc supplies.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – Power Cabling Install-DCT1900/R8/mw 19- 9 © 2000-2005 Factory Fitted Po wer Cabling The Modular Cabinet is delivered with the following powering cables fitted: z Cable TRENB 101 02 (19024 8) between the filter and the lower fuse holders (see Fig ure 19– 11 ) .
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – Power Cablin g 19-10 Install-DCT1900/R8/mw © 2000-2005 Fig. 19–1 1 Power Connections to T op of Filter (3A/250V) Upper Fuses Lower Fuse (15A/250V) Switch Wrist S trap connector Filter X112 X113 X102 + - AC input connector DC input/output connectors Fig.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – Power Cabling Install-DCT1900/R8/mw 19-11 © 2000-2005 19.5 Installation Modular Cabinet Powered by an Externa l 300W.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – Power Cablin g 19-12 Install-DCT1900/R8/mw © 2000-2005 C L U / S L U C L U / S L U C L U / S L U Bac k Pl an e A B M.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – Power Cabling Install-DCT1900/R8/mw 19-13 © 2000-2005 Base St ation Power Supplied to a Maximum of 7 CLUs/SLUs via the PW–EXT Input on th e MCCB This requires a power supply with a capacity of greater tha n 300W , such as a PBX p ower supply .
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – Power Cablin g 19-14 Install-DCT1900/R8/mw © 2000-2005 C L U / S L U C L U / S L U C L U / S L U Back Plane A B MCCB.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – CPU Cabling Install-DCT1900/R8/mw 20- 1 © 2000-2005 C HAPTER 20 Modular Cabinet – CPU Cabling 20.1 Introduction This chapter descr ib es all th e cab ling con n ec t ed to the CPU1, REX-BRD0004 or 2/ROFNB 157 19/2, and to the CPU2 , REX-BRD9033 or REX-BRD9034.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – CPU Cabling 20-2 Install-DCT1900/R8/mw © 2000-2005 20.2 CPU1 Cabling Fig.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – CPU Cabling Install-DCT1900/R8/mw 20- 3 © 2000-2005 Fig. 20-2 Connections to SDB Connections to the SDB For the connections to the SD B also refer to Ch apter 18: 1.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – CPU Cabling 20-4 Install-DCT1900/R8/mw © 2000-2005 Fig. 20-3 Cable Tie Blocks on the Ground S trip Connection to the PC, Printer , and SMS System 1. Connect PC cable (TSRNB 101 22D) to the PC connector on the MCCB and to the PC.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – CPU Cabling Install-DCT1900/R8/mw 20- 5 © 2000-2005 Fig. 20-4 G eneral Alarm Connector (MCCB) Connection to Alarm Device The General Alarm relay is normally activated when the Modular Cabinet is switched on.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – CPU Cabling 20-6 Install-DCT1900/R8/mw © 2000-2005 should be on the left, with the pins facing towards yo u. Pin A1 is in the upper lef t corner , while pin C7 is in the lower right corner .
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – CPU Cabling Install-DCT1900/R8/mw 20- 7 © 2000-2005 20.4 CPU2 Cabling Fig.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – CPU Cabling 20-8 Install-DCT1900/R8/mw © 2000-2005 Connection to Alarm Device The General Alarm relay is normally activated when the Modular Cabinet is switched on. If the CPU generates a general alar m, the alarm re lay is deactivated.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – CPU Cabling Install-DCT1900/R8/mw 20- 9 © 2000-2005 Fig. 20-7 CPU2 Sync Cable for up to 2 REs CPU2 to CPU2 - More th.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – CPU Cabling 20-10 Install-DCT1900/R8/mw © 2000-2005 Fig. 20-8 CPU 2 Sync Cable for more than 2 REs 20.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – CPU Cabling Install-DCT1900/R8/mw 20-11 © 2000-2005 Fig. 20-9 CPU1 to CPU2 Connection Wh it e/ B lu e Blue/White CPU 1 (Master) CPU 2 (Slave) RJ-45 4 5 INPUT Connect Pins A3 and C5 of CPU 1 to pins 4 and 5 of CPU 2.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – CPU Cabling 20-12 Install-DCT1900/R8/mw © 2000-2005 Fig. 20-10 CPU2 to CPU1, CPU2 Master , CPU1 Slave, Multiple REs .
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – CLU/SLU to Base Stat ion Cabling Install-DCT1900/R8/mw 21- 1 © 2000-2005 C HAPTER 21 Modular Cabinet – CLU/SLU to Base S t ation Cabling 21.1 Introduction This chapter descr ib es all th e cab lin g betwe e n the CLU or SLU an d th e Bas e S tation.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – CLU/SLU to Base Station Cablin g 21-2 Install-DCT1900/R8/mw © 2000-2005 21.2 Inst allation of Cables Note: Base S tations with cables longer than 1.3 miles up to 2.17 miles must always be conne cted to a CLU with product code REX-BRD0014 or ROFNB 157 1 1/2.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – CLU/SLU to Base Stat ion Cabling Install-DCT1900/R8/mw 21- 3 © 2000-2005 Fig. 21–2 CLU/MDF Cable Connections on t he CLU or SLU Base St ation Power The following installatio n steps are necessary when the Base S tations are powere d via the Modular Cabinet.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – CLU/SLU to Base Station Cablin g 21-4 Install-DCT1900/R8/mw © 2000-2005 DCT 1900 66 BLOCK B A S E S T A T IO N WIRIN G TOP BASE ST A T I ON NO. 2 * BASE ST A T I ON NO.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – CLU/SLU to Base Stat ion Cabling Install-DCT1900/R8/mw 21- 5 © 2000-2005 Fig.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – CLU/SLU to Base Station Cablin g 21-6 Install-DCT1900/R8/mw © 2000-2005 Fig.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – CLU/SLU to Base Stat ion Cabling Install-DCT1900/R8/mw 21- 7 © 2000-2005 Record Keeping Make a copy of the Base S tation identification and location sheet included at the end of this chapter and fill in the information as you add your Base S tations.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – CLU/SLU to Base Station Cablin g 21-8 Install-DCT1900/R8/mw © 2000-2005 T able 21–2 Identification of the Cable Pa.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – CLU/SLU to Base Stat ion Cabling Install-DCT1900/R8/mw 21- 9 © 2000-2005 T able 21-3 CLU to 66 Block Cabling Connect.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – CLU/SLU to Base Station Cablin g 21-10 Install-DCT1900/R8/mw © 2000-2005 T able 21-3 CLU to 66 Block Cabling (cont.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – CLU/SLU to Base Stat ion Cabling Install-DCT1900/R8/mw 21-11 © 2000-2005 Base St ation Identification and Location S.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – CLU/SLU to Base Station Cablin g 21-12 Install-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – DTU Cabling Install-DCT1900/R8/mw 22- 1 © 2000-2005 C HAPTER 22 Modular Cabinet – DTU Cabling 22.1 Introduction This chapter describes th e installation of the cabling betw een the DTU(s) and MS/PBX by means of twisted pair cables.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – DTU Cabling 22-2 Install-DCT1900/R8/mw © 2000-2005 22.2 Inst allation - DTU-E1 Connecting the DTUs to the MS/PBX 1. Ensure the DTU strap settings are in the t wisted pair position (refer to Chapter 1 1 ).
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – DTU Cabling Install-DCT1900/R8/mw 22- 3 © 2000-2005 22.3 In st allation - DTU-T1 (CAS or CCS) Connecting the DTUs to the MS/PBX 1. Ensure the DTU strap settings are in the twisted p air position (refer to Chapters 12 & 13).
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – DTU Cabling 22-4 Install-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – LTU Cabling Install-DCT1900/R8/mw 23- 1 © 2000-2005 C HAPTER 23 Modular Cabinet – L T U Cabling 23.1 Introduction This chapter descr ib es th e ins tallation of the ca blin g be tw een the L TU(s) and the PBX.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – LTU Cabling 23-2 Install-DCT1900/R8/mw © 2000-2005 23.2 Inst allation The six connectors on the L TU end of the cables are labelled 1 through 6 and should be inst alled as shown in Figure 23-2.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – LTU Cabling Install-DCT1900/R8/mw 23- 3 © 2000-2005 The amphenol end of the cable is pinned out as follows: T able 2.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – LTU Cabling 23-4 Install-DCT1900/R8/mw © 2000-2005 T able 23-1 L TU to 66 Block Cabling (cont.
Technical Product Manu al - DCT1900 Installation Instructions, Modular C abinet – DLU Cabling Install-DCT1900/R8/mw 24- 1 © 2000-2005 C HAPTER 24 Modular Cabinet – DLU Cabling 24.1 Introduction This chapter describes the installation of the cabling betwee n the DLU(s) and the PBX.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – DLU Cabling 24-2 Install-DCT1900/R8/mw © 2000-2005 Fig. 24–2 DLU Board RS232 Serial Port LED1 LED2 LED3 LED4 RJ45 .
Technical Product Manu al - DCT1900 Installation Instructions, Modular C abinet – DLU Cabling Install-DCT1900/R8/mw 24- 3 © 2000-2005 24.3 Connection to PBX’ s Connecting the DLUs to the PBX 1.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – DLU Cabling 24-4 Install-DCT1900/R8/mw © 2000-2005 DLU Cable Diagram: T able.
Technical Product Manu al - DCT1900 Installation Instructions, Use of TDR Install-DCT1900/R8/mw 25- 1 © 2000-2005 C HAPTER 25 Use of TDR 25.1 Introduction When programming Remote Base S tations usin g the CSMW Software, it is necessary to determine the time delay of t he Base S t ation ca ble.
Technical Product Manual - DCT 1900 Installation Instructions, Use of TDR 25-2 Install-DCT1900/R8/mw © 2000-2005 10. A waveform similar to the one shown in Fi gure 25 -1 should be d isplayed, ho wever the vertical pulse will be located at the left e dge of the screen.
Technical Product Manu al - DCT1900 Installation Instructions, Use of TDR Install-DCT1900/R8/mw 25- 3 © 2000-2005 Examples : .17189 should be rounded to .
Technical Product Manual - DCT 1900 Installation Instructions, Use of TDR 25-4 Install-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – Cables Install-DCT1900/R8/mw 26- 1 © 2000-2005 C HAPTER 26 Modular Cabinet – Cables This chapter gives an overview of the cables used in a system with Mo dular Cabinets.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – Cables 26-2 Install-DCT1900/R8/mw © 2000-2005 26.3 MCCB Power Cable – TRENB 101 03 The MCCB power cable (see Figur e 26–2) is a 2–wire unshielded cable with co nnectors on both sides.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – Cables Install-DCT1900/R8/mw 26- 3 © 2000-2005 26.4 Power Cable Swit ch/Fuse – TRENB 101 04 The power cable switch/f use is a 2–wire 2.5mm 2 cable with two connectors on both sides.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – Cables 26-4 Install-DCT1900/R8/mw © 2000-2005 26.5 Power Cable Switch/Backplane – TRENB 101 05 The power cable switch/backplan e (s ee Figure 26–4 ) is a 2–wire 2.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – Cables Install-DCT1900/R8/mw 26- 5 © 2000-2005 26.6 PC or SMS Cable – TSRNB 101 22D The PC cable (see Figure 26–5 ) is used to connec t both the CSM PC a nd a SMS Server or device to the MCCB.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – Cables 26-6 Install-DCT1900/R8/mw © 2000-2005 26.7 Printer Cabl e – TSRNB 101 23 The printer cable (see Figure 26–6) is used to connect the printe r to the MCCB. The maximum permissible length fo r self–made cables is 49 ft.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – Cables Install-DCT1900/R8/mw 26- 7 © 2000-2005 26.8 CPU/MCCB Serial Connect ion Cable – TSRNB 101 26 The CPU/MCCB .
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – Cables 26-8 Install-DCT1900/R8/mw © 2000-2005 Fig. 26–8 CPU/MCCB Serial Connection Cable – TSRNB 10 1 26 K2 2 " .
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – Cables Install-DCT1900/R8/mw 26- 9 © 2000-2005 26.9 General Alarm Cable – TSRNB 101 28 The general alarm ca ble (see Figure 26–9) is used to connect the gene ral alarm output o f the CPU to the MCCB.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – Cables 26-10 Install-DCT1900/R8/mw © 2000-2005 26.10 CLU/MDF Cable Set – NTM/TSRNB 101 29 The CLU/MDF Cable Set (see Figures 26- 10 through 26-12) consists of two shielded cables (TSRNB 101 29/1 and TSRNB 101 29/2 ).
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – Cables Install-DCT1900/R8/mw 26-11 © 2000-2005 Fig. 26–10 CLU Cable Conn ector A 29 37 28 12 EP0 EP1 31 36 30 11 S.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – Cables 26-12 Install-DCT1900/R8/mw © 2000-2005 Fig. 26–1 1 CLU Cable Connector B 29 49 28 24 EP0 EP1 31 48 30 23 S.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – Cables Install-DCT1900/R8/mw 26-13 © 2000-2005 Fig. 26–12 CLU/MDF Cable Set NTM/TSRNB 101 29 32 30 28 26 24 22 20 .
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – Cables 26-14 Install-DCT1900/R8/mw © 2000-2005 26.1 1 L TU/MDF Cable Set – NTM/TSRNB 101 31 The L TU/MDF Cable Set (see Figure 26-13 ) is used for the connection of the L TU to an MDF .
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – Cables Install-DCT1900/R8/mw 26-15 © 2000-2005 26.12 CLU/MCCB Power Cable – TSRNB 101 33 The CLU/MCCB power cable .
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – Cables 26-16 Install-DCT1900/R8/mw © 2000-2005 Fig. 26–15 CLU/MDF Cable Set NTM/TSRNB 101 46 1 2 3 4 5 6 7 8 17 18.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – Cables Install-DCT1900/R8/mw 26-17 © 2000-2005 Fig. 26–16 CLU/MDF Cable Set NTM/TSRNB 101 46 (cont’d) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 K1 82 ft " 4 in K1 13 in or 18 in 2 in 13 IN .
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – Cables 26-18 Install-DCT1900/R8/mw © 2000-2005 26.14 CPU1/SDB T wisted Pair Sync Cable – T SRNB 101 48 The CPU/SDB twisted pair sync cable connects a CPU1 sync port to the SDB and is a pa rt of the insta llation set sync port NTMNB 101 107.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – Cables Install-DCT1900/R8/mw 26-19 © 2000-2005 26.15 DTU T wisted Pair Cable Set – NTM/ TSRNB 101 49 or A W S1033 (E1-120 ohm) The DTU twisted p air cable A WS1033 (see Figures 26–18) cons ists of a 120 ohm shielded ca ble terminated with two conn ectors.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – Cables 26-20 Install-DCT1900/R8/mw © 2000-2005 26.16 DTU/MDF T wisted Pair Cable – TSRNB 101 50 or A WS1 034 (T1 - 100 ohm) The DTU/MDF twisted pair ca ble A WS1034 (see Figure 26– 19) consist of a 100 ohm shielded cable terminated with two connecto rs.
Technical Product Manu al - DCT1900 Installation Instructions, Modular Cabinet – Cables Install-DCT1900/R8/mw 26-21 © 2000-2005 26.17 SYNC Cable - TSR 951 284 The sync cable is used on all DCT1900 MS ap p lications that require intersystem handover between m ultiple REs with CPU1 boa rds.
Technical Product Manual - DCT 1900 Installation Instructions, Modular Cabinet – Cables 26-22 Install-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Commissioning Comm-DCT1900/R7/mw © 2000-2005 Section 6 Commissioning.
Technical Product Manual - DCT 1900 Commissioning Comm-DCT1900/R7/mw © 2000-2005.
Technical Product Manu al - DCT1900 Commissioning, Table of Contents Comm-DCT1900/R8/mw I © 2000 T able of Contents C HAPTER 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Product Manual - DCT 1900 Commissioning, Table of Contents II Comm-DCT1900/R8/mw © 2000.
Technical Product Manu al - DCT1900 Commissioning, Introduction Comm-DCT1900/R8/mw 1-1 © 2000-2005 C HAPTER 1 Introduction This section describes a series of chec ks and tests that have to be ex ecuted after complet ing the installation and initializat ion of the DCT1900 syste m.
Technical Product Manual - DCT 1900 Commissioning, Introduction 1-2 Comm-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Commissioning, Synchronization Test Comm-DCT1900/R8/mw 5-1 © 2000-2005 C HAPTER 5 Synchronization T est 5.1 General This test checks if tw o DCT1900 systems, w hose coverage areas pa rtly overlap and are connected to the same synchro nization network, ar e correctly syn chronized.
Technical Product Manual - DCT 1900 Commissioning, Synchronization Test 5-2 Comm-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Commissioning, Radio Coverage Verification Comm-DCT1900/R8/mw 4-1 © 2000-2005 C HAPTER 4 Radio Coverage V erification 4.1 General The radio coverage verification consist s of two tests: z Base S tation test z Area coverage test Ensure that the Base S tations are properly installed.
Technical Product Manual - DCT 1900 Commissioning, Radio Coverage Verification 4-2 Comm-DCT1900/R8/mw © 2000-2005 3. Move closer to ea ch Base S t ation and check tha t the Por table T elephone locks to it (the DCA should display the corr ect Base S t ation number).
Technical Product Manu al - DCT1900 Commissioning, Radio Coverage Verification Comm-DCT1900/R8/mw 4-3 © 2000-2005 DISPLA Y LA YOUT MER TEST [1.] Frame Coun t The frame count field cont ains a running cou nte r of the number of frames that have been examined.
Technical Product Manual - DCT 1900 Commissioning, Radio Coverage Verification 4-4 Comm-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Commissioning, Portable Telephone Test Comm-DCT1900/R8/mw 3-1 © 2000-2005 C HAPTER 3 Port able T elephone T est 3.1 General This test checks for a complete connection of a Portable T ele phone through t he DCT1900 system to the MS/PBX.
Technical Product Manual - DCT 1900 Commissioning, Portable Telephone Test 3-2 Comm-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Commissioning, Visual Checks Comm-DCT1900/R8/mw 2-1 © 2000-2005 C HAPTER 2 V isual Checks 2.1 General Visual inspection consist s of checking the LEDs on the system boards and the availability of all system boards and Base S tations.
Technical Product Manual - DCT 1900 Commissioning, Visual Checks 2-2 Comm-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Commissioning, Radio Exchange Tests Comm-DCT1900/R8/mw 6-1 © 2000-2005 C HAPTER 6 Radio Exchange T ests 6.1 General Alarm This test is only necessary if an alarm device is connected to the genera l alarm relay on the MCCB.
Technical Product Manual - DCT 1900 Commissioning, Radio Exchange Tests 6-2 Comm-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Maintenance Maint-DCT1900/R8/mw © 2000-2005 Section 7 Maintenance.
Technical Product Manual - DCT 1900 Maintenance Maint-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Maintenance, Table of Contents Maint-DCT1900/R8/mw I © 2000-2005 T able of Contents C HAPTER 1 Maintenance Philosophy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1.
Technical Product Manual - DCT 1900 Maintenance, Table of Contents II Maint-DCT1900/R8/mw © 2000-2005 C HAPTER 4 Service Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 4.1 Service Message Format .
Technical Product Manu al - DCT1900 Maintenance, Maintenance Philosophy Maint-DCT1900/R8/mw 1-1 © 2000-2005 C HAPTER 1 Maintenance Philosophy 1.1 Concept of Maintenance The DCT1900 mainte nance philosophy is to undert ake componen t repair and rep l acement at the Ascom Wireless Solutions Repair Department.
Technical Product Manual - DCT 1900 Maintenance, Maintenance Philosophy 1-2 Maint-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Maintenance, Test and Maintenance Software Maint-DCT1900/R8/mw 2-1 © 2000-2005 C HAPTER 2 T e st and Maintenance Sof tware 2.1 Introduction The DCT1900 system has a po werful T est & Ma intenance module incorporated in the system software.
Technical Product Manual - DCT 1900 Maintenance, Test and Maintenance Software 2-2 Maint-DCT1900/R8/mw © 2000-2005 Fig. 2–1 Board Controllers an d Per ipherals 2.2 Error Handling The T&M softwa re in the CPU is activated either on detection of operational faults , or when a test has to be executed.
Technical Product Manu al - DCT1900 Maintenance, Test and Maintenance Software Maint-DCT1900/R8/mw 2-3 © 2000-2005 z An additional fault report will be written in a third table called "Service" t able. z A general alarm is raised. z An alarm message is sent to the MS (Mobility only).
Technical Product Manual - DCT 1900 Maintenance, Test and Maintenance Software 2-4 Maint-DCT1900/R8/mw © 2000-2005 Error detected by Testi ng Operati onal Fa ult Fault class? St a tus L(og ged ) in Info Table. Diagnosti cs. Fault still prese nt? Status C(le ar) in Fault Table.
Technical Product Manu al - DCT1900 Maintenance, Test and Maintenance Software Maint-DCT1900/R8/mw 2-5 © 2000-2005 2.2.3 Maintenance If the fault counte r does not exceed its limits, T&M will now try to correct the er ror by resetting the circuit or board.
Technical Product Manual - DCT 1900 Maintenance, Test and Maintenance Software 2-6 Maint-DCT1900/R8/mw © 2000-2005 2.3 T esting The T&M module has three te st s available to che ck the overall system performan ce and to report any deviatio ns in performance .
Technical Product Manu al - DCT1900 Maintenance, Test and Maintenance Software Maint-DCT1900/R8/mw 2-7 © 2000-2005 status A VE. Base S tations that are wired to the CLU/SLU and have power but have not been added to the system through the CS MW will get the status NEW .
Technical Product Manual - DCT 1900 Maintenance, Test and Maintenance Software 2-8 Maint-DCT1900/R8/mw © 2000-2005 Board Power–on Reset A board power–on rese t is generated when: z System is switched on. z CPU reset button is pressed. z Board inserted in the system.
Technical Product Manu al - DCT1900 Maintenance, Test and Maintenance Software Maint-DCT1900/R8/mw 2-9 © 2000-2005 Relative Counters A relative counter coun ts all reset s since the power–on. The counter is cleared e ach tim e the power is cycled or at a CPU rese t (but ton or watch–dog).
Technical Product Manual - DCT 1900 Maintenance, Test and Maintenance Software 2-10 Maint-DCT1900/R8/mw © 2000-2005 PO : Power–on all boards : means all boards, exc ept the CPU + : counter incremen.
Technical Product Manu al - DCT1900 Maintenance, Fault Signalling Maint-DCT1900/R8/mw 3-1 © 2000-2005 C HAPTER 3 Fault Signalling 3.1 Introduction This chapter describes how maintenance perso nnel or system managers are informed about fault s in the DCT1900 system.
Technical Product Manual - DCT 1900 Maintenance, Fault Signalling 3-2 Maint-DCT1900/R8/mw © 2000-2005 3.3 Checking Component St atus th rough Cordless System Manager Checking radio Checking radio exchange comp on ent s maybe done to verify fault reports from the service t able or to check proper connection of base st ations af ter inst allation.
Technical Product Manu al - DCT1900 Maintenance, Fault Signalling Maint-DCT1900/R8/mw 3-3 © 2000-2005 Base St at ion (BS) St at es MFG : Base S t ation defective, data cable wiri ng fault, or download of software incorrec t. Also a fuse on CLU/SLU is down.
Technical Product Manual - DCT 1900 Maintenance, Fault Signalling 3-4 Maint-DCT1900/R8/mw © 2000-2005 Before any part of the system is suspected, it sh ould be made clear that no handling faults have occurred. T ypical handling faults are: Portab le T elephone out–of–range, battery em pty or Port able T elephone not switched on.
Technical Product Manu al - DCT1900 Maintenance, Fault Signalling Maint-DCT1900/R8/mw 3-5 © 2000-2005 Fig 3–1 LEDs in the System 3.7.1 LEDs on System Boards Each board has four LEDs at the top. The SLU has two times four LEDs because it con sists of a SPU and a CLU on one board, each with it s own board controller and board address.
Technical Product Manual - DCT 1900 Maintenance, Fault Signalling 3-6 Maint-DCT1900/R8/mw © 2000-2005 3.7.2 LEDs on CPU The CPU is the only board havin g six LED s. LE Ds 1 to 4 are iden tical to the LEDs on other boards. LED 5 and 6 are found below the reset button .
Technical Product Manu al - DCT1900 Maintenance, Fault Signalling Maint-DCT1900/R8/mw 3-7 © 2000-2005 3.7.3 LEDs on Base St ation Power LED Green LED indicates the Base S tation is powered.
Technical Product Manual - DCT 1900 Maintenance, Fault Signalling 3-8 Maint-DCT1900/R8/mw © 2000-2005 3.8.1 Activating DCA mode 1. Switch off th e Portable T elephone : 2. Switch on again with special code: + + (Press the 3 keys simultaneously for longer than 1 seco nd) 3.
Technical Product Manu al - DCT1900 Maintenance, Fault Signalling Maint-DCT1900/R8/mw 3-9 © 2000-2005 When you are done testing, turn the portable of f to exit DCA mode. 5. For DT600 and DT 620 scroll menu down to:Gen. Setup (press Y es) Note: If using the DT620 or the DT600 rev .
Technical Product Manual - DCT 1900 Maintenance, Fault Signalling 3-10 Maint-DCT1900/R8/mw © 2000-2005 The Link Info option can be used for site survey s and commissioning of th e system. All information regarding the speech /beacon channel and system to which the Portable T elephone is lock ed is visible.
Technical Product Manu al - DCT1900 Maintenance, Fault Signalling Maint-DCT1900/R8/mw 3-1 1 © 2000-2005 This option enables the display of information for a selected channe l.
Technical Product Manual - DCT 1900 Maintenance, Fault Signalling 3-12 Maint-DCT1900/R8/mw © 2000-2005 MER test s 1. MER short 2. MER long Last Error This menu informs you of the last fatal er ror that o ccurred in the port able telephon e.
Technical Product Manu al - DCT1900 Maintenance, Service Messages Maint-DCT1900/R8/mw 4-1 © 2000-2005 C HAPTER 4 Service Messages 4.1 Service Message Format Service messages are displayed in the service table have the following fo rm at: Fault 35 on DTU circuit 1 76 2 10/07 14:25 Fault Code : Number identifying the fault, see T able 4-1.
Technical Product Manual - DCT 1900 Maintenance, Service Messages 4-2 Maint-DCT1900/R8/mw © 2000-2005 4.3 Fault Codes T able 4-1 shows all fault reports that may appear in the service t able.
Technical Product Manu al - DCT1900 Maintenance, Service Messages Maint-DCT1900/R8/mw 4-3 © 2000-2005 T able 4–1 Fault Codes in Service T able Fault Code Service class Fault Threshol d Descript ion 1 2 5 Unex pected messa ge/primitiv e. Message r eceived b ut not within specified tim e 2 1 99 Board/CP U communi cation err or or time out.
Technical Product Manual - DCT 1900 Maintenance, Service Messages 4-4 Maint-DCT1900/R8/mw © 2000-2005 4.3.1 Comment to Fault Codes z Fault 17 ... 26, 28, 29, 41 CPU faults . Replacement of the CPU requires saving of its d ata to PC first by "System Manager-Save/Restore".
Technical Product Manu al - DCT1900 Maintenance, Part Replacement Maint-DCT1900/R8/mw 5-1 © 2000-2005 C HAPTER 5 Part Replacement 5.1 General Rules z Always protec t yourself with a prop erly connected ESD w rist–strap before t ouching any board . z Pack replaced boards immediately in ESD safe materia l.
Technical Product Manual - DCT 1900 Maintenance, Part Replacement 5-2 Maint-DCT1900/R8/mw © 2000-2005 Procedure 1. Switch off the system. 2. Disconnect the cables from the CPU. 3. Replace the CPU and re–con nect the cables. 4. Switch the system on.
Technical Product Manu al - DCT1900 Maintenance, Part Replacement Maint-DCT1900/R8/mw 5-3 © 2000-2005 5. For the three slot s farthest to the right, di scon nect the cabling and remove th e boards (the three slots farthest to the left if the new cabinet comes at the left side).
Technical Product Manual - DCT 1900 Maintenance, Part Replacement 5-4 Maint-DCT1900/R8/mw © 2000-2005 - Execute Add command for the New Base S tations in the Base S t ations window . z SLU boards: - Execute Replace comma nd for the CLU. Remove and re -insert in to new position.
Technical Product Manu al - DCT1900 Maintenance, Part Replacement Maint-DCT1900/R8/mw 5-5 © 2000-2005 5.9 Board Reset T o rese t a bo ar d exec ute one of the following pro ce du re s . Procedure A 1. Execute a Reset-board by the System M anager- Control menu.
Technical Product Manual - DCT 1900 Maintenance, Part Replacement 5-6 Maint-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Maintenance, Fault Finding Procedures Maint-DCT1900/R8/mw 6-1 © 2000-2005 C HAPTER 6 Fault Finding Procedures 6.1 Introduction These fault finding procedure s are designed to hel p maintenance personnel locate and eliminate faults in the shorte st possible time.
Technical Product Manual - DCT 1900 Maintenance, Fault Finding Procedures 6-2 Maint-DCT1900/R8/mw © 2000-2005 6.3 How Defective It ems are Indicated When the flowchart s lead to a possible cause, this is indicated b y a statement giving the name of the defectiv e part or the cause of the problem, e.
Technical Product Manu al - DCT1900 Maintenance, Fault Finding Procedures Maint-DCT1900/R8/mw 6-3 © 2000-2005 GENERAL ALARM System M a nage r - Con tro l - S ervice Fault 8, 35, 36, 37, or 41? No Rep.
Technical Product Manual - DCT 1900 Maintenance, Fault Finding Procedures 6-4 Maint-DCT1900/R8/mw © 2000-2005 A Check supply voltage at Base Stat ion Voltage <½ x PSU voltage? Check Base Station data lines connections Cable correct? Check CLU/SLU wiring.
Technical Product Manu al - DCT1900 Maintenance, Fault Finding Procedures Maint-DCT1900/R8/mw 6-5 © 2000-2005 B Fault 37? Check air int erface sync provider Out of order or re set? Check sync inpu t cable connect ion at CPU and SDB.
Technical Product Manual - DCT 1900 Maintenance, Fault Finding Procedures 6-6 Maint-DCT1900/R8/mw © 2000-2005 COMMON USER COMPLAINT All Portables out of range? Green LED on all Boards on? Yes Yes CPU.
Technical Product Manu al - DCT1900 Maintenance, Fault Finding Procedures Maint-DCT1900/R8/mw 6-7 © 2000-2005 INDIVI DUAL USER COMPLAINT Disp lay o f Portable rem ains totally blank? Out of range message displayed? Is the correct PUN selected? Replace battery pack by a charged one and switch on Portable again.
Technical Product Manual - DCT 1900 Maintenance, Fault Finding Procedures 6-8 Maint-DCT1900/R8/mw © 2000-2005 NO DIAL TONE Press the "YES" key on the Portable. Flashing or stable hook icon displayed? Switch off the Portable and then on again.
Technical Product Manu al - DCT1900 Maintenance, Fault Finding Procedures Maint-DCT1900/R8/mw 6-9 © 2000-2005 INDIVIDUAL USE R COMPLAINTS Portable display remains blank "NoSystem" displayed.
Technical Product Manual - DCT 1900 Maintenance, Fault Finding Procedures 6-10 Maint-DCT1900/R8/mw © 2000-2005 ERRORS System List Error Buzzer Data Error Fixed Phone book Error User Data Er ror Initialization Error END No No No No No Yes Yes Yes Yes Yes Initialization data missing or corrupted.
Technical Product Manu al - DCT1900 Maintenance, Fault Finding Procedures Maint-DCT1900/R8/mw 6-1 1 © 2000-2005 CSM PROBLEM "No connection with DCT1900" m essage on PC display? Check PC cab.
Technical Product Manual - DCT 1900 Maintenance, Fault Finding Procedures 6-12 Maint-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Glossary Glosst-DCT1900/R8/mw © 2000-2005 Section 8 Glossary.
Technical Product Manual - DCT 1900 Glossary Gloss-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Glossary, Table of Contents Maint-DCT1900/R8/mw I © 2000-2005 T able of Contents C HAPTER 1 Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Product Manual - DCT 1900 Glossary, Table of Contents II Gloss-DCT1900/R8/mw © 2000-2005.
Technical Product Manu al - DCT1900 Glossary Gloss-DCT1900/R8/mw 1-1 © 2000-2005 C HAPTER 1 Glossary The following are abbrevia tions used in the entire T echnical Produc t Manual: ADPCM Adaptive Dif.
Technical Product Manual - DCT 1900 Glossary 1-2 Gloss-DCT1900/R8/mw © 2000-2005 RSSI Receive d Sign al S trength Indication RTC Real T ime Clock SDB Synchronization Distribution Board SLU S peech Li.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Nortel Networks DCT1900 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Nortel Networks DCT1900 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Nortel Networks DCT1900 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Nortel Networks DCT1900 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Nortel Networks DCT1900, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Nortel Networks DCT1900.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Nortel Networks DCT1900. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Nortel Networks DCT1900 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.