Manuale d’uso / di manutenzione del prodotto B5SM -090 del fabbricante Nordyne
Vai alla pagina of 16
LIGHT COMMERCIAL AIR HANDLER Installation Instructions B5SM -090/120 SERIES Horizontal Application - Rear View Horizontal Application - Fr ont View V ertical Application Please read this information thor oughl y and become familiar with the capabilities and use of y our appliance before attempting to operate or maintain this unit.
2 Important Safety Information ....................................3 General Information ...................................................4 Bef ore Y ou Install this Unit .........................................4 Locating the Air Handler ..........
3 IMPORT ANT SAFETY INFORMA TION Saf ety markings are used frequently throughout this manual to designate a degree or le v el of seriousness and should not be ignored. W ARNING indicates a potentially hazardous situation that if not av oided, could result in personal injur y or death.
4 GENERAL INFORMA TION B5SM air handlers are shipped from the f actor y ready f or installation in a horizontal position. The units can be easily re- confi gured in the fi eld for v er tical applications.
5 AIR HANDLER INST ALLA TION P ackaging Remo v al Remov e the shipping crate and User’ s Manual from the equipment. T ake care not to damage the tubing connections when removing the crate .
6 • The B5SM-120 air handler has a dual circuit coil and the B5SM-090 has a single circuit coil. • The B5SM-120 air handler is charged through ser vice v alves on the end of the liquid tube f or each circuit. These must be remo ved bef ore brazing the line sets .
7 ELECTRICAL WIRING W ARNING: T o av oid risk of electrical shock , personal injury , or death, disconn ect all electrical power to the unit before per forming an y maintenance o r s e r v i c e . T h e u n i t m a y h a v e m o r e t h a n o n e electrical suppl y .
8 ST ARTUP AND ADJUSTMENTS Pre-Start Check List Prior to star t-up, complete the f ollo wing inspection: V erify the unit is lev el and condensate can drain. Check condensate drain line(s) f or proper slope and trap . V er ify the air handler is mounted securely .
9 Figure 3. Proper Belt T ension 1/4 inch 1 foot Pulley Alignment Inspect the pulley alignment betw een the motor sheav e and blo wer pulle y . If a misalignment occurs, adjust the location of the motor sheav e b y loosening the set-screw in the stationar y f ace of the motor sheav e.
10 13 5/8" 15 9/16" 17 11/16" 17 13/16" 4 3/16" 4 3/8" 5 11/16" 8 3/16" Air Flow Electrical Connections 2 7/32" 3/4" 1 1/4" 18 13/16" Supply.
11 Figure 5. B5SM Physical Dimensions f or V er tical Installations 23" Return Duct Opening 5 1/16" 53 1/4" Cabinet Height 53" Return Duct Opening 57" Filter Rack Frame 60 1/4.
12 Model Motor Sheave P osition External Static Pressures (Inches Water Column) 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw B5SM- 090 (2HP) 60 Hz Fully Closed 4182 666 1.
13 SINGLE PHASE THREE PHASE G C W2 W1 O/B Y R G C W2 W1 O/B Y R L2 L1 G L3 L2 L1 G L1 L2 G FIELD SUPPL Y CONNECTIONS L1 L2 L3 G FIELD SUPPL Y CONNECTIONS L1 L2 T1 T2 L1 L2 T1 T2 L3 T3 208-230/460V 460 208-230 460 208 - 230 Electrical Configurations 1.
14 Figure 7. T ypical Air conditioner Thermostat Connections BLOWER MO TOR GND T O FIELD SUPPLIED DISCONNECT SINGLE ST AGE HEA T/COOL THERMOST A T OUTDOOR SECTION FREEZEST A T SINGLE ST AGE HEA T/COOL.
15 Figure 8. T ypical Heat Pump Thermostat Connections BLOWER MO TER GND BLACK BLACK GREEN BRO WN T O FIELD SUPPLIED DISCONNECT SINGLE ST AGE HEA T PUMP THERMOST A T OUTDOOR SECTION NO TE 1 NO TE 2 FR.
7090950 Specifi cations and illustrations subject to change without notice or incurring obligations. Printed in U.S .A. (01/10) Installed by: Date Installed: Maintenance T ask WM S A A A ir Filters Inspect, c lean or replace as required.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Nordyne B5SM -090 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Nordyne B5SM -090 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Nordyne B5SM -090 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Nordyne B5SM -090 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Nordyne B5SM -090, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Nordyne B5SM -090.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Nordyne B5SM -090. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Nordyne B5SM -090 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.