Manuale d’uso / di manutenzione del prodotto MSU480 del fabbricante Niles Audio
Vai alla pagina of 20
MSU480 INFRARED MAIN SYSTEM UNIT MSU480 B LENDING H IGH F IDELITY AND A RCHITECTURE ® INST ALLA TION & OPERA TION GUIDE DS00330ACN/MSU480 12/19/03 9:05 AM Page 20.
T A BLE OF CONTENTS Introduction 1 Features and Benefits 2 MSU480 Par ts Guide 4 Installation Considerations 5 Installation 8 T esting the IR Extender System 1 2 Power Status 14 T rouble- Shooting 1 6.
I NFRARED M AIN S YS TEM U NIT 2 Featur es and Benefits The MSU480 of fers a number of improvements over other IR Extender Main System Units: • Universal system—compatible with virtually all brands of A/V equipment and remote controls. • Accommodates four IR sensors or keypads.
I NFRARED M AIN S YS TEM U NIT 3 1 2VDC/ 200mA OUTPUT 1 23 45 67 8 FLASHER OUTPUTS MSU480 IR MAIN SYSTEM UNIT POWER +12V DC 3-30V AC/DC S TATUS IN CONTACT CLOSURE INPUT 1 INPUT 2 INPUT 3 INPUT 4 HI LO.
1 2VDC/ 200mA OUTPUT 1 23 45 67 8 FLASHER OUTPUTS MSU480 IR MAIN SYSTEM UNIT POWER +12V DC 3-30V AC/DC S TATU S IN CONTACT CLOSURE INPUT 1 INPUT 2 INPUT 3 INPUT 4 HI LOW HI LOW STA TUS IR 4 I NFRARED M AIN S YS TEM U NIT MSU480 Par ts Guide 1. 12V DC Jack – Provides 12 volt DC power to MSU via a regulated power supply .
Installation Considerations Placement of the MSU480 Place the MSU480 conveniently close to the equipment it will be controlling. Generally , the unit is placed in a concealed location because its controls and indicators are only used dur- ing installation.
W iring Fr om every IR Sensor location you must “home-run” a category 5 cable back to the MSU480. Home run means that an individual cable is connected between each IR Sensor and the MSU480 (Figure 4). 6 I NFRARED M AIN S YS TEM U NIT “TECH TIP” W ire size is expressed by it’ s AWG (American Wi re Gauge) number .
Intellipad W iring When you ar e placing both an IntelliPad and a sensor (or two keypads) in one room you may “daisy-chain” using a single cable. A cable is run between the keypad and the sensor and a single cable is run from either the sensor back to the MSU480.
System Expansion System expansion is easily achieved (Figur e 6) through the use of an IRH610 Infrared Sensor Expansion Hub. Please see your authorized Niles dealer or refer to the IRH610 manual for details.
9 I NFRARED M AIN S YS TEM U NIT 12VDC/ 200mA OUTPUT 1 23 45 67 8 FLASHER OUTPUTS MSU480 IR MAIN SYSTEM UNIT POWER +12V DC 3-30V AC/DC STATUS IN CONTACT CLOSURE INPUT 1 INPUT 2 INPUT 3 INPUT 4 HI LOW .
I NFRARED M AIN S YS TEM U NIT 10 STEP 1. Connect and test the power supply . If it tests OK, unplug the connector from the power socket and proceed. 2. Connect the Sensor/ Keypad cable the Sensor input. 3. T est for shorts and interference. DESCRIPTION A) Plug the supplied 12VDC power supply into an unswitched 100-240V AC outlet .
I NFRARED M AIN S YS TEM U NIT STEP 4. Plug the flashers into the flasher outputs. If you need to extend the wire, use a 2-conductor 16 gauge or larger (See “T ech Tip” on Page 6). DESCRIPTION Route the connecting wire to the IR Main System Unit. Connect the 3.
12 I NFRARED M AIN S YS TEM U NIT T esting the IR Extender System T est your IR Extender system by following the three principal guidelines: 1. All components can be operated. T est all of your remote controls for all of your equipment. 2. Operation is consistent.
13 I NFRARED M AIN S YS TEM U NIT 12 V olt T rigger Output The Niles MSU480 pr ovides a 12VDC output that can be trig- gered one of two ways: 1. The presence of status voltage on the 3-30V AC/DC status input jack or 2. Discrete infrared on and off commands.
14 I NFRARED M AIN S YS TEM U NIT Contact Closur e The Niles MSU480 pr ovides a contact closure that can be triggered one of two ways: 1. The presence of status voltage on the 3-30V AC/DC status input jack or 2.
15 I NFRARED M AIN S YS TEM U NIT Power Status — Installation Considerations Proper Power Supply Y ou may connect a Niles 12VDC wall adapter (Niles FG00665) into the switched AC power outlet of the preamp/receiver in your system. Any 3-30V AC/DC power supply with a minimum of 20mA current capacity can be substituted.
16 I NFRARED M AIN S YS TEM U NIT 2. Optical or Electromagnetic Interference Dir ect sunlight, reflections, neon signs and other sources of infrared light or television sets, light dimming controls and other sources of electromagnetic fields can induce noise and interference into your IR extender system.
1 7 I NFRARED M AIN S YS TEM U NIT Specifications IR System Compatible with virtually all brands of remotes using carrier frequencies between 26 and 1 05kHz. W iring Requirements Individual home-runs of category 5 cable from each sensor/keypad. Unit Dimensions 7-1/16” wide x 1-1/4” high x 3” deep Power Requir ements 12 VDC 1.
Addendum: Using the MSU480 with the IntelliContr ol ® automation system 1 8 I NFRARED M AIN S YS TEM U NIT mA 2 3 4 5 6 FLA S HE R OU TP U T S MSU 480 U I R MAIN S Y S TEM U NI T +1 2V D C CO NTA CT .
N iles Audio Corporation www .nilesaudio.com 1 233 1 S.W . 1 30 Street Miami, Florida, 33 186 T el: (305) 238-4373 Fax: (305) 238-0 1 85 © 2004 Niles Audio Corporation. All rights reserved. Niles, the Niles logo, IntelliPad and Blending High Fidelity and Architecture are registered trademarks of Niles Audio Corporation.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Niles Audio MSU480 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Niles Audio MSU480 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Niles Audio MSU480 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Niles Audio MSU480 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Niles Audio MSU480, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Niles Audio MSU480.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Niles Audio MSU480. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Niles Audio MSU480 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.