Manuale d’uso / di manutenzione del prodotto 21 del fabbricante New Buck Corporation
Vai alla pagina of 42
MODEL 21 NON-CA T AL YTIC UNIT EATURES PREPARATIONS INSTALLATION OPERATION MAINTENANCE SAFETY SAFETY NOTICE IF THIS HEATER IS NOT PROPERLY IN STALLED, A HOUSE FIRE MAY RESULT .
.
T ABLE OF CONTENTS Important Instructions ……………………………………………………………………………2 SECTION I: Introduction ………………………………………………………………………..3 SECTION II: Masonry In sert Installation……………………………………………………….
INST ALLA TION, OPERA TION, AND MAINTENANCE INSTRUCTIONS MODEL 21 READ THIS FIRS T IMPOR T ANT INSTRUCTIONS W ARNING THIS UNIT GENERATES A L OT OF HEAT , SO TREAT THE UNIT WITH CARE. HOT WHILE IN OPERATION! KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS.
CAUTION YOUR CHIMNEY OR FLUE MUST BE CO RRECTLY SIZED. A CHIMNEY OR FLUE THAT IS TOO SMALL OR LARGE IN DIAMETER, OR TOO SHORT, CAN CAUSE YOUR STOVE TO SPILL SMOKE WHEN THE DOOR IS OPENED.
SECTION II MASONR Y INSER T INST ALLA TION The Model 21 may be installed using an all masonr y fireplace built in accordance with the Uniform Building Code and National Fire Prot ection Association (NFPA). The first step in this type of installation is to determine the acceptability of th e fireplace and chimney for use with a woodstove.
Floor Protection: When installing freestanding heater ,a floor protector must be use. Floor protection m ust be 3/8” minimum thickness non-combustible material or equivalent .R=0.06 How to use alternate materials and how to ca lculate equivalent thickn ess.
POSSIBLE TOOLS NEEDED FOR INST ALLA TION If you decide to install your own stove, there are several hand tools you may need to do the job. If you do not already have them, they are r eadily available at mo st hardware stores.
OPTION (B) REMOVE DAMPER OR WIRE IT OPEN AIRTIGHT INSULATED CLEAN- BLOCK-OFF PLATE OR DAMPER ADAPTER SEAL TRIM PANELS WITH INSULATION OR HIGH TEMPERATURE CAULK STAINLESS STEEL CHIMNEY CONNEC- TOR MUST EXTEND 1’ PAST THE BLOCK-OFF PLATE OR TO THE FLUE LINER NOTE: Follow installation instruction with Direct Connection Kit.
INST ALLA TION PROCEDURE (Use a Listed Direct or Positive Connect) FIGURE 2 POSITIO N ING 3. Slide the unit out of the fire pl ace far enough to work behind the trim panel reference lines. 4. Mount the side trim panels. (See Figure 3) a. Position the trim panel on the reference lin e.
10. If direct connect or positive c o nnect kit is not used, follow i nstructions in (mounting trim panels, steps 1-4c) on (Page 8) . 11. Mount top trim panel by drilling m ounting holes in center of trim panel mounting brackets, with top end side of top panel overl apping side panel.
CAUTION THE UNIT IS PAINTED WITH A SPECIALLY FORMULATED HIGH TEMPERATURE PAINT THAT CURE S DURING THE FIRST TWO OR THREE FIRINGS. YOU MAY NOTICE A SLIGHT SMOKING EFFECT AND AN ODOR OF BURNING PAINT WHEN YOU BUILD THE FIRST FIRES. THIS IS NORMAL AND IS NOT A CA USE FOR ALARM.
SECTION III PRE-F AB INSER T INST ALLA TION The Model 21 has been test ed with the following: Heatilator Security Tempco Preway Marco FMI Woodside Majestic NOTE: The Model 21 may be installed in any of the pre-fabricated frieplaces listed above if they are big enough to accept the heater.
SECTION IV RESIDENTIAL AND MOBILE HOME FREEST ANDING INST ALLA TION Select an installation location that will gi ve t he best airflow from the front of t he heater to the remainder of the home. PREP ARING THE ST OVE FOR INST ALLA TION 1. Inspect the unit for any obvious physical damage.
Floor Protection: Floor protection must be 3/8” minimum thickne ss non-com bustible material or equivalent. How to use alternate materials and how to ca lculate equivalent thickn ess. An easy means of determining if a proposed altern ate floor protector meet s requirements listed in the appliance manual is to follow this procedure: 1.
PREP ARING THE ROOM HEA TER LOCA TION 1. Select an installation location that will give th e best airflow from the front of the heater to the remainder of the home. 2. Place the protective floor pad in position. 3. Place the unit on the pad m aking sure the mi nimum clearance specifications are met.
A. V ertical exit using (6" Single W all minimum 24 ga. blued or black pipe, and any listed 2100° UL 103 HT . TYPE C himney). W ithout optional close clearanc e shield, and pipe shield.
HOW TO LOCA TE CHIMNEY EXIT , AND INST ALL Residential Installation. B. Vertical Wall Exit using (6" Single Wall minimum 24 ga. blued or black pipe with elbow, and any Listed 2100° UL HT chimney and Listed 2100° UL HT.
B. V ertical wall exit using (6" Single W all minimum 24 ga. blued or black pipe with elbow , and any listed 2100° UL 103 HT . TYPE Chimney and Listed 2100° UL HT . T -Box assembly ). W i thout optional close cleara nce shield and pipe shield. Model 21 minimum cleara nce to combustibles.
HOW TO LOCA TE CHIMNEY EXIT , AND INST ALL Residential and Mobile Home Installation. C. Vertical Exit using (6" DVL Close Clearance pipe, and any Listed 2100° UL 103 HT chimney). W ithout close clearance shield and pipe shield. NOTE: For minimum cleara nces (See Page 19, Figure 11).
C. V ertical exit using (6" DVL Close Clearance pipe, and any listed 2100° UL 103 HT . T YPE Chimney). W ithout optional close clearanc e shield, and pipe shield.
HOW TO LOCA TE CHIMNEY EXIT , AND INST ALL Residential and Mobile Home Installation. D. Vertical Wall Exit using (6" DVL Close Cl earance Pipe, and Elbow, and any Listed 2100° UL HT chimney and Listed 2100° UL HT T-Box assembly). Without op tional close clearance shield and pipe shield NOTE: For minimum cleara nces (See Page 21, Figure 13).
D. V ertical wall exit using (6" DVL Cl ose Clearance pipe with elbow) and any listed 2100° UL 103 HT . TYPE Chimney , and Listed 2100° UL HT T -Box assembly ). W i thout optional close cleara nce shield and pipe shield. Model 21 minimum cleara nce to combustibles.
HOW TO LOCA TE CHIMNEY EXIT , AND INST ALL Residential and Mobile Home Installation. E. Vertical Exit using (6" DVL Close Clearance pipe, and any Listed 2100° UL 103 HT chimney). W ith optiona l close clearance shield and p i pe shield. NOTE: For installation o f of optional close clearance shield s and pipe shield (See Page 33).
E. V ertical exit using (6" DVL Close Clearance pipe, and any listed 2100° UL 103 HT . T YPE Chimney). W ith optional close clearance shield, and pipe shield.
HOW TO LOCA TE CHIMNEY EXIT , AND INST ALL Residential and Mobile Home Installation. F. Vertical Wall Exit using (6" DVL Close Cl earance Pipe, and Elbow, and any Listed 2100° UL HT chimney and Listed 2100° UL HT T-Box assembly).
F. V ertical wall exit using (6" DVL Cl ose Clearance pipe with elbow and any listed 2100° UL 103 HT . TYPE Chimney , and Listed 2100° UL HT T -Box assembly ). W ith optional close clearance shield and pipe shield. Model 21 minimum cleara nce to combustibles.
OUT SIDE AIR INST ALLA TION 1. Select an installation location th at will give the best airflow f rom the front of the heater to the remainder of the home. CAUTION THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR MUST BE MAIN- TAINED. (MOVE OPENING AND/OR REPOSITI ON HEATER LOCATION IF NECESSARY).
14. From under the mobile home, slip the duct up through the 4-1/4" ho le. Push up until the face of the outside air duct contacts the unders ide of the floor of the m obile home. For certain floor thickness, you may have to shor ten the length of the outside air duct.
FINAL CHECK 1. Recheck the specified clearances. 2. Remove all foreign mate rial from the firebox area. 3. Open the primary air draft. 4. Plug the power cord into a 115V AC outlet when using with optional motor. 5. Place crum pled pieces of newspaper in the stove.
SECTION VI ALCOVE INST ALLA TION AND CLEARANCES Select an installation location that will gi ve t he best airflow from the front of t he heater to the remainder of the home. PREP ARING THE ST OVE FOR INST ALLA TION 1. Inspect the unit for any obvious physical damage.
Floor Protection: Floor protection must be 3/8” minimum thickne ss non-com bustible material or equivalent. How to use alternate materials and how to ca lculate equivalent thickn ess. An easy means of determining if a proposed altern ate floor protector meet s requirements listed in the appliance manual is to follow this procedure: 1.
HOW TO LOCA TE CHIMNEY EXIT , AND INST ALL Alcove Installation. E. Vertical Exit using (6" DVL Close Clearance pipe, and any Listed 2100° UL 103 HT chimney). W ith optiona l close clearance shield and p i pe shield. NOTE: For installation o f of optional close clearance shield s and pipe shield (See Page 33).
ALCOVE INST ALLA TION AND CLEARANCES E. V ertical exit using (6" DVL Close Clearance pipe, and any listed 2100° UL 103 HT . T YPE Chimney). W ith optional close clearance shield, and pipe shield.
Installation of (Optional) Clos e Clearance Shields and Pipe Shield 1. Taking close clearance side sh ields, hold up to side of st ove leaving 1/4" gap between shield and top of stove. 2. Make reference mark in center of pre-punched ho le in top & bottom of shield.
FINAL CHECK 1. Recheck the specified clearances. 2. Remove all foreign mate rial from the firebox area. 3. Open the primary air draft. 4. Plug the power cord into a 115V AC outlet when using with optional motor. 5. Place crum pled pieces of newspaper in the stove.
SECTION VI WOOD HEA TER SAFETY Certain safety hazards are inhe rent in any wood heater installa tion. You should be aware of these so that a safe and proper installation can be made. 1. FAULTY CHIMNEY: An older masonry chim ney should be thoroughly checked to be sure there are no holes or weak spots which coul d allow sparks or hot gases to escape.
SECTION VII OPERA TION This section of the manual is to help you ge t the maximum efficiency and maximum smoke (particulate) reduction from your heater. If you should experience any difficulty or have any questions concer ning your heater, contact your dealer for assistance.
SECTION VIII TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION 1. Sluggish Heater 1. Obstruction in Chimney 2. Improperly sealed trim kit or direct connect kit 3. Manual damper in chimney is closed 4. Wet or unseasoned wood being burned 5. Poor chimney draft 1.
2. High fuel consumption 3. Backpuffing 4. Smoke rollout when heater door is opened 1. (a) Close inlet air control as much as possible to maintain desired heat output. (b) Check gaskets, reinstall fiberglass gasketing round doors and glass as necessary 2.
NEW BUCK CORPORA TION (NBC) "LIMITED W ARRANTY" FOR THE BUCK ST OVE PLEASE READ THIS W ARRANTY CAREFULL Y PRODUCTS COVERED This warranty covers the New Buck Stove h eating unit, so long as i.
If for any reason you are dissatisfied with the suggested procedures, you may contact us in writing at: New Buck Corporation Customer Service Department P. O. Box 69 Spruce Pine, NC 28777 CONDITIONS AND EXCLUSIONS A. Replacement of parts may be in the f orm of new or fully recondition ed parts, at NBC's option.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il New Buck Corporation 21 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del New Buck Corporation 21 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso New Buck Corporation 21 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul New Buck Corporation 21 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il New Buck Corporation 21, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del New Buck Corporation 21.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il New Buck Corporation 21. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo New Buck Corporation 21 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.