USER GUIDE USB-6501 OEM This user guide describes how to use the National Instruments USB-6501 OEM data acquisition (DA Q) de vice. The NI USB-6501 OEM is a full-speed USB 2.0 de vice that provides 24 DIO channels and a 32-bit counter . Dimensional Drawings Figure 1 shows a top view of the US B-6501 OEM.
USB-6501 OEM U ser Guide 2 ni.com Figure 2. USB-6501 OEM Dimensions (Front and Rear Views) Block Diagram Figure 3 shows key functional compo nents of the USB-6501 OEM device. Figure 3. Device Bl ock Diagram Refer to the Safety G uidelines section of this document for im portant safety information.
© National Instruments Corporatio n 3 USB-6501 OEM User Guide I/O Connector and Cable Use any 34-pin female IDC (ribbon) cable to connect to th e IDC connector on the USB-6501 OEM device. Table 1 lists the pin assignments and sign al names for the IDC connector.
USB-6501 OEM U ser Guide 4 ni.com Signal Descriptions Table 2 describes the signals available on the I/O connectors. Digital I/O The USB-6501 OEM has 24 single-ended digital lines, P0.<0..7>, P1.<0..7>, and P2.<0.. 7>, which com p rise the three DIO ports.
© National Instruments Corporatio n 5 USB-6501 OEM User Guide Figure 4. Example of Connecting Extern al User -Provided Resistor Complete the following steps to determine the v alue of the user-provided pull-up resistor: 1. Place an ammeter in se ries with the load.
USB-6501 OEM U ser Guide 6 ni.com Figure 5. Example of Connecting a Load Caution Exceeding the maximum input voltage ratin gs or maximum output ratings, which are listed in the Specifications section, can damage the D A Q de vice and the computer . National Instruments is not liable for any damage resulting from such signal connections.
© National Instruments Corporatio n 7 USB-6501 OEM User Guide Power - On States At system startup and reset, the hardware sets all DIO lines to high-impedance inputs. The DAQ devi ce does not drive the signal high or low. Each line has a weak pu ll-up resistor connected to it.
USB-6501 OEM U ser Guide 8 ni.com Pull-up resistor .................... ................ ....4.7 k Ω VBus (nominally 5 V) Absolute voltage range .................. .........– 0.5 to 5.8 V with respect to GND Power-on state .............. .........
© National Instruments Corporatio n 9 USB-6501 OEM User Guide Power Requirements USB 4.10 to 5.25 VDC ..................... ....... 80 mA typical, 500 mA max USB Suspend ........ .............. ............ 300 µ A standby mode, 500 µ Am a x Physical Characteristics Dimensions .
USB-6501 OEM User Guide 10 ni.com specially protected secondary circuits . Such voltage measureme nts include signal le vels , special equipment, limited-energ y parts of equipment, circuits powered b y regulated lo w-v oltage sources, and electronics.
© National Instruments Corporation 11 USB-6501 OEM User Guide Note Refer to the Declaration of Conformity (DoC) for this product fo r any additional regulatory compliance informatio n.
USB-6501 OEM User Guide 12 ni.com A void contact between your bo dy and the connector block signal w hen hot swapping modules. Remove po wer from signal lines b efore connecting them to or disconnecting them from the device. Operate the device at or belo w the Measurement Category I 1 .
National Instruments, NI, ni.com, and LabVIEW are tradem arks of National Instruments Corporation. Refer to t he Terms of Use section on ni.com/legal for mor e information abou t National Instruments trademarks. Other product and compan y names mentioned herein are t rademarks or trade names of their respective companie s .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il National Instruments USB-6501 OEM è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del National Instruments USB-6501 OEM - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso National Instruments USB-6501 OEM imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul National Instruments USB-6501 OEM ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il National Instruments USB-6501 OEM, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del National Instruments USB-6501 OEM.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il National Instruments USB-6501 OEM. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo National Instruments USB-6501 OEM insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.