Manuale d’uso / di manutenzione del prodotto FP-1000 del fabbricante National Instruments
Vai alla pagina of 12
FieldPoint ™ is a trademark of National Instruments Corporation. Product and company names are trademarks or trade names of their respective companies.
2 DIN Rail Mounting NOTE: Terminal bases must be connected to the network module before applying power to the module. Do not connect or disconnect terminal bases while power is applied to the network module. The FP-1000 has a simple rail clip for mounting reliably onto a standard 35 mm DIN rail.
3 4. Add terminal bases to the DIN rail with their local bus connectors firmly mated to the FP-1000 local bus connector. The FP-1000 is shipped with a protective cover over the local bus connector. Remove this protective cover, and place it over the local bus connector of the last terminal base in the stack.
4 Figure 4. RS-232 Connector Pinout Up to 24 additional FP-1001 network modules can be connected to this FP-1000 module by using the built in RS-485 repeater. This repeater makes the RS-485 port of the FP-1000 appear to the additional FP-1001 modules as if it were an RS-485 port of the host computer.
5 These connections are shown in Figure 6. Figure 6. Typical Signal Connections with One FP-1000 Connected to Multiple FP-1001 Network Modules Figure 6 also shows the use of 120 Ohm termination resistors. An RS-485 network must be terminated at each end of the network, but not anywhere else.
6 module is at address 22, and so on. A terminal base is assigned a network address whether an I/O module is inserted into it or not. Figure 7. Address and Baud Rate Switch Table 1 shows the possible switch positions and the corresponding address of the FP-1000.
7 Switches 6-8 set the baud rate of the FP-1000. Table 2 shows the switch positions and the corresponding network baud rates. 70 200 80 210 90 220 100 230 110 240 120 Other Settings Not Allowed Table 2.
8 Powering the FP-1000 NOTE: Terminal bases must be connected to the FP-1000, and the baud rate switch must be set, before power is applied to the FP-1000. An 11-30 VDC power supply is required by each FieldPoint stack. The network module filters and regulates this supplied power and provides power for all the I/O modules in the stack.
9 Specifications Network ports ................................... 1 RS-232 port, 1 RS-485 repeater port Baud Rates ........................................ 300, 1200, 2400, 9600, 19200, 38400, 57600, 115200 (switch selectable) Communication parameters .
10 Mechanical Dimensions Figure 9 shows the mechanical dimensions of the FP-1000. Figure 9. Mechanical Dimensions 4.31 [109.5] 3.58 [90.9] 4.19 [106.4] FP1000.
FP1000.fm Page 11 Thursday, July 31, 1997 8:49 AM.
FP1000.fm Page 12 Thursday, July 31, 1997 8:49 AM.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il National Instruments FP-1000 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del National Instruments FP-1000 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso National Instruments FP-1000 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul National Instruments FP-1000 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il National Instruments FP-1000, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del National Instruments FP-1000.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il National Instruments FP-1000. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo National Instruments FP-1000 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.