Fieldbus FBUS-HSE/H1 Linking Device (LD) User Manual FBUS-HSE/H1 LD User Manual May 2003 Edition Part Number 3707 28A-01.
Support Worldwide Technical Support and Product Info rmation ni.com National Instruments Corporate Headquarters 11500 North Mopac Expressway Aust in, Texas 78759-3504 USA Tel: 512 683 0100 Worldwide O.
Important Information Warranty The FBUS-HSE/H 1 Linking Device (LD) is wa rranted agai nst defects in materials and w orkmanshi p for a perio d of one year f rom the date of shipment, as evidenc ed by receipts or othe r documentation.
Compliance FCC/Canada Radio Frequency Interference Compliance Determining FCC Class The Federal Communications Commission (FCC) has rules to protect wireless co mmunications from inte rference.
© National Instruments Corporat ion v FBUS-HSE/H1 LD User Manual Contents About This Manual How To Use the Manual Set ............ ............ ........... .............. ........... .............. ............ .... vii Conventions ............ .....
Contents FBUS-HSE/H1 LD User Manua l vi ni.com Appendix D Technical Support and Professional Services Glossary Index.
© National Instruments Corporatio n vii FBUS-HSE/H1 LD User Manual About This Manual This manual describes the mechani cal and electrical aspects of the FBUS-HSE/H1 Linking Device (LD) and contains information con cerning its installation and operat ion.
About This Manual FBUS-HSE/H1 LD User Manua l viii ni.com programs, subprograms, su broutines, d evice names, functions, operations, variables, filenames and e xtensions, and code excerpts.
© National Instruments Corporatio n 1-1 FBUS-HSE/H1 LD User Manual 1 Over view of FBUS-HSE/H1 Linking Device (LD) Hardware This chapter provides an overview of the FBUS -HSE/H1 Linking Device (LD) hardware.
Chapter 1 Overview of FBU S-HSE/H 1 Li nking Devic e (LD) H ardware FBUS-HSE/H1 LD User Manua l 1-2 ni.com Figure 1-1 shows an FB US-HSE/H1 LD connected to an Ethernet network. Figure 1-1. T y pical Ethernet Network Setup In a distributed application, many Fieldb us H1 segments are network ed together using HSE LDs.
Chapter 1 Overview of FBUS-HSE/H 1 Linking Devi ce (LD) Hardware © National Instruments Corporatio n 1-3 FBUS-HSE/H1 LD User Manual Once configured, the linking de vice permits HMI software on any PC connected to an FBUS-HSE/H1 LD to access and monitor Fieldb us devices as if the HMI were directly conn ected to the Fieldbus network.
© National Instruments Corporatio n 2-1 FBUS-HSE/H1 LD User Manual 2 Hardware Installation and Configuration Installing the FBUS-HSE/H1 LD The FBUS-HSE/H1 LD has a simple rai l clip for reliable mounting o nto a standard 35 mm DIN rail. Complet e the follo wing steps to mount the FBUS-HSE/H1 LD on a DIN rail.
Chapter 2 Hardware Installa tion and Configuration FBUS-HSE/H1 LD User Manua l 2-2 ni.com Figure 2-2. Mounting the FBUS-HSE/H1 LD on a DIN Rail 3. Slide the FBUS-HSE/H1 LD to the de sired position alon g the DIN rail.
Chapter 2 Hardware Installa tion and Configuration © National Instruments Corporatio n 2-3 FBUS-HSE/H1 LD User Manual Mounting the FBUS-HSE /H1 LD to a Panel Complete the followin g steps to install the optional Fi eldbus network panel mount accessory and mount the FBUS -HSE/H1 LD network module to a panel.
Chapter 2 Hardware Installa tion and Configuration FBUS-HSE/H1 LD User Manua l 2-4 ni.com Connect Y our FBUS-HSE/H1 LD to the Network Connect the RJ-45 Ethernet port of th e FBUS-HSE/H1 LD to an Ethernet hub using a standard Category 5 Ethern et cable.
Chapter 2 Hardware Installa tion and Configuration © National Instruments Corporatio n 2-5 FBUS-HSE/H1 LD User Manual Cabling If you build your own cables, the following table shows the st andard Ethernet cable wiring connections for both normal and crossover cables.
Chapter 2 Hardware Installa tion and Configuration FBUS-HSE/H1 LD User Manua l 2-6 ni.com Connect the FBUS-HSE/H1 LD to the Fieldbus Network The FBUS-HSE /H1 LD ca n be one of up to 32 devices connected to a Fieldbus H1 network.
Chapter 2 Hardware Installa tion and Configuration © National Instruments Corporatio n 2-7 FBUS-HSE/H1 LD User Manual Connect Power to the FBUS-HSE/H1 LD Each FBUS-HSE/H1 LD on your network requires an 11-30 VDC power supply. The po wer connector is a 6-pin scre w terminal power connector whose pinout is shown in Figure 2-7.
© National Instruments Corporatio n A-1 FBUS-HSE/H1 LD User Manual A Resetting the FBUS-HSE/H1 LD If the FBUS-HSE/H1 LD cannot communicate with the network, you can configure the Ethernet settings through NI-FBUS software. When you configure the de vice, it attempts to confirm that the ne w settings are valid.
Appendix A Resetting the FBUS-HSE/H1 LD FBUS-HSE/H1 LD User Manua l A-2 ni.com Figure A-1. FBUS-HSE/H1 LD Reset Switch 3. Looking at the FBUS-HSE/H1 LD so that the label is upright, as shown in Figure A-1, use a pen or a smal l screwdr i ver to mov e the Reset switch to the right.
© National Instruments Corporatio n B-1 FBUS-HSE/H1 LD User Manual B T roubleshooting LED Indicators Hardware The FBUS-HSE/H1 LD has sev en LED indicators on the top panel and three LEDs on the front panel, as sho wn in Figure B-1.
Appendix B T roubleshooting FBUS-HSE/H1 LD User Manua l B-2 ni.com Figure B-1. LEDs on the FBUS-HSE/H1 LD Ethernet LEDs The six Ethernet LEDs are locat ed on the top panel. The green POWER LED is lit while the FBUS-HSE/H1 LD is powered up. This LED indicates th at the po wer supply connected to the FBUS-HSE/H1 LD is acceptable.
Appendix B T roubleshooting © National Instruments Corporatio n B-3 FBUS-HSE/H1 LD User Manual Caution Do not power do wn the FBUS-HSE/H1 LD while the PROCESS LED is lit. The green PROCESS LED is lit when you update the non v olatile flash memory of the FBUS-HSE/H1 LD.
Appendix B T roubleshooting FBUS-HSE/H1 LD User Manua l B-4 ni.com Module ST A TUS LED The module STATUS LED is located on the front of the linking device, between the two Fieldbus (H1 Network) connectors, as sho wn in Figure B-1. It indicates whether the linking device is powered, conf igured, and operating properly .
Appendix B T roubleshooting © National Instruments Corporatio n B-5 FBUS-HSE/H1 LD User Manual Standby state indicates the linking device has passed all self tests and is ready to operate. Howe ver , it is not functioning because no acti ve Ethernet segment is conf igured.
© National Instruments Corporatio n C-1 FBUS-HSE/H1 LD User Manual C Specifications This appendix describes the specifications of the FBUS-HSE/H1 LD. Network Network interface ....................... ........... . 10BaseT and 100BaseTX Ethernet Device interface .
Appendix C Specifications FBUS-HSE/H1 LD User Manua l C-2 ni.com Safety This product is designed to meet the requirements of the following standards for safety and electrical equi pment for measurement, control, and laboratory use: • IEC 60950, EN 60950 • UL 1950, UL 60950 • CAN/CSA C22.
© National Instruments Corporatio n D-1 FBUS-HSE/H1 LD User Manual D T echnical Support and Professional Ser vices Visit the following sections of the National Instruments Web site at ni.
Appendix D T echnical Su pport and Professio nal Ser vices FBUS-HSE/H1 LD User Manua l D-2 ni.com • Calibration Certificate —If your product supports calibration, you can obtain the calibration certificate for your product at ni.com/calibration . If you searched ni.
© National Instruments Corporatio n G-1 FBUS-HSE/H1 LD User Manual Glossar y Symbol Pref ix V alue m milli 10 –3 k kilo 10 3 Mm e g a 1 0 6 A A Amperes. A/D Analog-to-dig ital con verter Al arm. A notification the NI-FBUS Communications Manager software sends when it detects that a block leav es or returns to a particular state.
Glossary FBUS-HSE/H1 LD User Manua l G-2 ni.com Boolean Logical relational system having two v alues, each the opposite of the other , such as true and false or zero and one. bps Bits per second. buf fer T emporary storage for acquired or generated data.
Glossary © National Instruments Corporatio n G-3 FBUS-HSE/H1 LD User Manual device tag A name you assign to a Fieldbus de vice. DI Discrete input. digital Pertaining to data (signals) in the form of discrete (separate/pulse fo rm) integral v alues. directory A structure for organizing f iles in to con venient groups.
Glossary FBUS-HSE/H1 LD User Manua l G-4 ni.com Fieldbus network address Location of a board or device on the Fieldb us; theFieldbus node address. Foundation Fieldbus specification Communications network specifica tion created b y the Fieldbus Foundation.
Glossary © National Instruments Corporatio n G-5 FBUS-HSE/H1 LD User Manual L LAS See Link Ac t ive Sc h e du l e r . LD Linking device. LED Light-emitting diode. link A Foundation Fieldbus network is made up of devices connected by a serial bus. This serial b us is called a link.
Glossary FBUS-HSE/H1 LD User Manua l G-6 ni.com node Junction or branch point in a circuit. non-volatile memory Memory that does not require electricity to hold data. O object An element of an object dictionary . P parameter One of a set of network-visibl e v alues that makes up a function block.
Glossary © National Instruments Corporatio n G-7 FBUS-HSE/H1 LD User Manual sensor A de vice that responds to a physical stimulus (heat, light, sound, pressure, motion, flow , and so on), and produ ces a corresponding electrical signal. server Devic e that recei ves a me ssage request.
Glossary FBUS-HSE/H1 LD User Manua l G-8 ni.com W W aveform Multiple v oltage readings taken at a specific sampling rate..
© National Instruments Corporatio n I-1 FBUS-HSE/H1 LD User Manual Index C cables, 2-5 calibration certificate, D-2 CE compliance, C-2 compatibility informat ion, 1-3 configuration and monitoring, 1-.
Index FBUS-HSE/H1 LD User Manua l I-2 ni.com LEDs Ethernet LEDs, B-5 Ethernet STATUS LED flashes and corresponding erro rs (table), B-4 figure, B-2 H1 network status LEDs (table), B-5 module STATUS LE.
Index © National Instruments Corporatio n I-3 FBUS-HSE/H1 LD User Manual L LEDs Ethernet LEDs, B-2 figure, B-2 H1 network status LEDs (table), B-5 module STATUS LED (table), B-4 on top panel (figure).
Index FBUS-HSE/H1 LD User Manua l I-4 ni.com W Web professional services, D-1 technical support, D-1 worldwide technical support, D-2.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il National Instruments Fieldbus è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del National Instruments Fieldbus - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso National Instruments Fieldbus imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul National Instruments Fieldbus ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il National Instruments Fieldbus, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del National Instruments Fieldbus.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il National Instruments Fieldbus. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo National Instruments Fieldbus insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.