Manuale d’uso / di manutenzione del prodotto GVF40N del fabbricante Napoleon
Vai alla pagina of 24
1 W415-0319 / D / 08.03.05 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@nap oleon.
2 W415-0319 / D / 08.03.05 Hood Louvre Bracket Hinge Screen Louvre Installation & Removal Heat Shield S tand Off Removal Logo Placement 16-17 O PTIONS Patented Catalytic Glass Door Blower Installa.
3 W415-0319 / D / 08.03.05 NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0319 / D / 08.03.05 This fireplace may be installed in an aftermarket per- manently located, manufactured (mobile) home, where not pr ohibited by local codes . This fireplace is only for use with the type of gas indi- cated on the r ating plate .
5 W415-0319 / D / 08.03.05 This heater shall not be installed in a confined space or unusually tight construction unless pro- visions are provided for adequate combustion and ventila tion air .
6 W415-0319 / D / 08.03.05 50 If in this example a solid door separates Room 1 from Room 2, the volume of Room 2 could not be used. In this case the maximum BTU/h would be: Maximum BTU/h: 800 x 1000 =.
7 W415-0319 / D / 08.03.05 FIGURES 4 a-d PENINSULA OPEN-END SEE-THRU 4-SIDED.
8 W415-0319 / D / 08.03.05 Note: In order to avoid the possibility of exposed insula- tion or vapour barrier coming in contact with the fireplace body , it is recommended that the walls of the fireplace enclosure be “finished” (ie: drywall/sheetrock), as you would finish any other outside wall of a home.
9 W415-0319 / D / 08.03.05 Combustible materials may be installed flush with the front of the fireplace but must not cover any of the black face- areas of the fireplace. Non-combustible material (brick, stone or ceramic tile) may protrude in these areas.
10 W415-0319 / D / 08.03.05 FIGURE 14 Note: In order to avoid the possibility of exposed insula- tion or vapour barrier coming in contact with the fireplace body , it is recommended that the walls of the fireplace enclosure be “finished” (ie: drywall/sheetrock), as you would finish any other outside wall of a home.
11 W415-0319 / D / 08.03.05 Install the base panels as illustrated in steps 1-4 on page 9. Both side panels sit under the bracket tab . Holding the side panel in position, bend down the tab to secure.
12 W415-0319 / D / 08.03.05 Combustible materials may be installed flush with the front of the fireplace but must not cover any of the black face- areas of the fireplace. Non-combustible material (brick, stone or ceramic tile) may protrude in these areas.
13 W415-0319 / D / 08.03.05 PHAZER TM logs, glowing and charcoal embers, exclusive to Napoleon fireplaces, provide a unique and realistic glow- ing effect that is dif ferent in every installation. T ake the time to carefully position the embers for a maximum glowing effect.
14 W415-0319 / D / 08.03.05 The curtain mesh must be kept fully closed during opera- tion to help prevent accidental burns from occurring. The heater must not be used when the hood is re- moved. Hook the hood over the lip of the curtain support plate.
15 W415-0319 / D / 08.03.05 L36 LOUVRE INST ALLA TION FIGURE 32 a-c HOOD Attach the hood by pressing the top flange into the clips along the top of the louvre opening. Secure using a screw through the centre slot. LOWER LOUVRES Insert the hinge clips into the slots located at the bottom left and right corners of the unit.
16 W415-0319 / D / 08.03.05 Notes: Ornamental insets can not be used in conjunction with the catalytic door When using a catalytic door , glassed doors must be used on all other side or end openings. This unique patented catalytic system was designed to provide unparalleled safety and peace of mind.
17 W415-0319 / D / 08.03.05 Remove the thermodisc bracket from the top of the firebox. Remove the thermodisc from the bracket supplied in the blower kit and install the thermodisc into the fireplace bracket. Then replace the bracket in the location it was removed.
18 W415-0319 / D / 08.03.05 When lighting and re-lighting, the gas knob cannot be turned from pilot to off unless the knob is depressed. 1. STOP! Read the above safety information on this la- bel. 2. Set the thermostat to lowest setting. 3. Turn off all electric power to the fireplace.
19 W415-0319 / D / 08.03.05 THIS PROCEDURE MUST BE PERFORMED BY A QUALIFIED SERVICE PERSON! Inspect the pilot for any visible contamination or debris (usually lint, pet hair , spider webs, carpet fibre, etc.) and remove. Disconnect the pilot from the pilot tubing line.
20 W415-0319 / D / 08.03.05 Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor .
21 W415-0319 / D / 08.03.05.
22 W415-0319 / D / 08.03.05 Main burner goes out; pilot stays on. Pilot flame is not large enough or not engulfing the thermopile - service or replace Oxygen Depletion Sensor System - correct piping and/or regulator to provide correct pressure Thermopile shorting - clean thermopile connection to the valve.
23 W415-0319 / D / 08.03.05 White / grey film forms on the glass of the optional cata- lytic door . Sulphur from fuel is being deposited on glass, logs or combustion chamber sur- faces. - clean the glass with a recommended gas fireplace glass cleaner .
24 W415-0319 / D / 08.03.05 W olf Steel Fireplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Dealer.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Napoleon GVF40N è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Napoleon GVF40N - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Napoleon GVF40N imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Napoleon GVF40N ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Napoleon GVF40N, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Napoleon GVF40N.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Napoleon GVF40N. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Napoleon GVF40N insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.