Manuale d’uso / di manutenzione del prodotto GDS25N GDS25P del fabbricante Napoleon
Vai alla pagina of 28
1 W415-0547 / B / 05.08.06 W415-0547 / B / 05.08.06.
2 W415-0547 / B / 05.08.06 WHA T T O DO IF Y OU SMELL GAS Do not touch any electrical switch. If you cannot reach your gas supplier , call the fire department. Do not try to light any appliance. Do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone.
3 W415-0547 / B / 05.08.06 WARNING • The stov e is a vented g as-fired hea ter . Do not burn wood or other ma terials in this stove . • Adults and especially childr en should be aler ted to the hazards of high surface tempera tures and should stay a way to a void burns or c lothing ignition.
4 W415-0547 / B / 05.08.06 NAPOLEON products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certi fi cate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
5 W415-0547 / B / 05.08.06 The blower power cord must be connected into a properly grounded receptacle. The grounding prong must not be re- moved from the cord plug. FOR YOUR SATISFACTION, THIS STOVE HAS BEEN TEST- FIRED TO ASSURE ITS OPERATION AND QUALITY! Minimum inlet gas supply pressure is 4.
6 W415-0547 / B / 05.08.06 MAINT AIN THESE MINIMUM CLEARANCES T O COMBUSTIBLES: A. 4" B. 2" * C. 2" STOVE SHOULD NOT BE INST ALLED DIRECTL Y ON CARPETING . MINIMUM 48" FROM STOVE TOP TO CEILING TO CEILING FROM STOVE TOP ...........
7 W415-0547 / B / 05.08.06 BL O WER INST ALLA TION 4 5 8 2 3 1 9 7 7 4 Blower ( SEE LOCA TION AND CLEARANCES ) 1. Cut and remove the tie securing the blower switch wires to the heat shield. 2. Connect the white wire coming from below the unit to the terminal on the blower .
8 W415-0547 / B / 05.08.06 * * * * * Recommended to pr event condensa tion on windows and thermal break age ** ** ** ** * * It is recommended to use a hea t shield and to maximiz e the distance to vinyl c lad sof fits. *** *** *** *** ** * The periscope GD-201 r equires a minim um 18 inc hes c learance fr om an inside corner .
9 W415-0547 / B / 05.08.06 Use only Wolf Steel, Simpson Dura-V ent, Selkirk Direct T emp or American Metal Amerivent venting components. For Simpson Dura-V ent, Selkirk Direct T emp and American Metal Amerivent, follow the installation procedure provided with the venting components.
10 W415-0547 / B / 05.08.06 USE GD201 PERISCOPE KIT BELOW GRADE INSTALLATION MAXIMUM 10FT VENT LENGTH OF HORIZONTAL REGARDLESS VENT LENGTH 24" MINIMUM 12"MINIMUM Use the GD201 periscope kit to locate the air termination above grade.
11 W415-0547 / B / 05.08.06 ELBOW VENT LENGTH V ALUES DEFINITIONS HORIZONT AL TERMINA TION 0 2.5 5 7 .5 1 0 1 2.5 1 5 4 0 1 0 2 0 3 0 1 7 .5 2 0 3 9 REQUIRED VERTICAL RISE IN FEET (V T ) CALCULA TED H.
12 W415-0547 / B / 05.08.06 V 1 HORIZONT AL TERMINA TION 20 1 0 0 5 1 0 1 5 9 0 1 00 1 20 11 0 3 0 4 0 5 0 6 0 7 0 8 0 1 3 0 1 4 0 1 5 0 20 See graph to determine the required vertical rise V T for the required horizontal run H T .
13 W415-0547 / B / 05.08.06 VERTICAL TERMIN A TION V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 = 3 ft H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03(one 45º elbow + three 90º elbows - 135º) = .03(45+90+90+90-135)=5.4 H T = H R + H O = 5.
14 W415-0547 / B / 05.08.06 H 1 VERTICAL TERMIN A TION 0 5 1 0 1 5 2 0 1 0 2 0 3 2 5 3 0 1 9 F or mula 1: H T < 3V T F or mula 2: H T + V T < 40 feet Example 4: V 1 = 1 ft when (H T ) > (V T ) Simple venting con fi gurations See graph to determine the required vertical rise V T for the required horizontal run H T .
15 W415-0547 / B / 05.08.06 VERTICAL THR OUGH EXISTING CHIMNEY This appliance is designed to be attached to a 3" co-lin- ear aluminum fl ex vent system running the full length of a masonry chimney . The fl exliner accommdates any contours of a masonry chimney , however , it is necessary to keep the fl exible liner as straight as possible.
16 W415-0547 / B / 05.08.06 This application occurs when venting through an exterior wall. Having determined the air terminal location, cut and frame a hole in an exterior wall with a minimum rectangle opening of 10" x 9". IMPORT ANT : FOR OPTIMUM PERFORMANCE, THE STOVE PIPE SHOULD RISE ¼" PER FOOT OF RUN.
17 W415-0547 / B / 05.08.06 1. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support.
18 W415-0547 / B / 05.08.06 1. Attach the adjustable pipe to the last section of rigid pip- ing. Secure with screws and seal. 2. Install the 4" aluminium fl exible liner to the stove. Secure with 3 screws and fl at washers. Seal the joint and screw holes using high temperature sealant.
19 W415-0547 / B / 05.08.06 FINISHING GLASS DOOR INST ALLA TION AND REMO V AL CAST FRONT INST ALLA TION AND REMO V AL FRONT SCREWS BRACKET 3 2 Follow the above steps in reverse in order to reinstall the door . Ensure that the bottom of the door meets the door retainer before closing the latches.
20 W415-0547 / B / 05.08.06 LOG PLA CEMENT LOGO PLA CEMENT LOGO 1.27cm 1.27cm Remove the backing from the the logo and position onto the control door as shown. It is not necessary to remo ve the cast fr ont, howev er , this will mak e for a mor e simple log installation.
21 W415-0547 / B / 05.08.06 OPTIONAL SWIT CH / WIRING DIAGRAM The on/off switch is located on the back of the GDS25 at the top right corner . For ease of acces- sibility , an optional remote wall switch or millivolt thermostat may be installed in a convenient location.
22 W415-0547 / B / 05.08.06 1. STOP! READ THE ABOVE SAFETY INFORMA TION ON THIS LABEL. 2. TURN REMOTE W ALL SWITCH TO OFF POSITION. 3. TURN OFF ALL ELECTRIC POWER TO THE FIREPLACE AND REMOVE BA TTERIES. 4. THIS FIREPLACE IS EQUIPPED WITH AN IGNITION DEVICE WHICH AUTOMA TICALL Y LIGHTS THE PILOT .
23 W415-0547 / B / 05.08.06 NOTE: Check and adjust, if necessary , the primary air to 7 / 16 ” for propane and 1 / 4 ” for natural gas. Replace the screws. 7. T urn on the gas supply and check for gas leaks by brushing on a soap and water solution.
24 W415-0547 / B / 05.08.06 Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor. When ordering replacement parts always give the following information: 1.
25 W415-0547 / B / 05.08.06 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.
26 W415-0547 / B / 05.08.06 Pilot will not light. V erify the "S" wire for the sensor and the "I" wire for the ignitor are connected to the correct terminals (not reverse) on the module and pilot assembly . V erify no loose connections, electrical shorts in the wiring or ground out to any metal object.
27 W415-0547 / B / 05.08.06 Flames are very ag- gressive. - V enting action is too great. T ighten door clamps Restrict vent exit with restrictor plate. See Restricting V ents. - Door is ajar Main burner fl ame is a blue, lazy , transparent fl ame. - Blockage in vent.
28 W415-0547 / B / 05.08.06 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Napoleon GDS25N GDS25P è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Napoleon GDS25N GDS25P - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Napoleon GDS25N GDS25P imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Napoleon GDS25N GDS25P ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Napoleon GDS25N GDS25P, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Napoleon GDS25N GDS25P.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Napoleon GDS25N GDS25P. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Napoleon GDS25N GDS25P insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.