1 W415-0689 / 06.25.08 INST ALLA TION AND OPERA TION INSTRUC TIONS W olf Steel Ltd., 24 Napoleon Rd ., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 ww w .napoleonreplaces .com • ask@napoleon.on.ca CERTIFIED UNDER CANADIAN AND AMERICAN NA TIONAL ST ANDARDS: CR97-003 ● CAN-2.
2 W415-0689 / 06.25.08 ! W ARNING PG 2-5 INTRODUCTION W arranty General Instructions General Information / Rates and Ef fi ciencies Care of Glass and Plated Parts Dimensions 5-7 INST ALLA TION Gas In.
3 W415-0689 / 06.25.08 NAP OL E ON® products are manuf actured under th e strict Standar d of the world recognized ISO 9001 : 2000 Q uality Assur ance Certifi cate. NAP OL EON ® products are designed with superior components and materials, assembled by train ed cra ftsmen who tak e great pride in their work .
4 W415-0689 / 06.25.08 THIS GAS APPLIANCE SHOULD BE INST ALLED AND SERVICED BY A QUALIFIED INST ALLER to conform with local codes. Installation practices vary from region to region and it is important.
5 W415-0689 / 06.25.08 FIGURES 1a-c DIMENSIONS Note: All gas connections must be contained within the appliance when complete. 1. The appliance is designed to accept a 1/2” gas supply line. The appliance is equipped with a 1/2” manual shut-off valve.
6 W415-0689 / 06.25.08 ! W ARNING CLEARANCES T O COMB USTIBLES MINIMUM CLEARANCES TO COMBUSTIBLES: - 18” to top - 1” to sides - 8” to bottom - 0” to rear Do NOT use the appliance if any part has been under water . Call a quali fi ed service technician IMMEDIA TEL Y to have the appliance inspected for damage to the electrical circuit.
7 W415-0689 / 06.25.08 G G J I K A C D E F H B B INST ALLA TIONS CANADA U.S.A. A 8 INCHES 8 INCHES Clearance above grade, veranda porch, deck or balcony . B 12 INCHES 9 INCHES Clearance to windows or doors that open. C 12 INCHES* 12 INCHES* Clearance to permanently closed windows.
8 W415-0689 / 06.25.08 2 MOUNTING BRACKET 4 3 KEYHOLE INSTALLATION TEMPLATE TORCH MOUNTING FRAME CABINET 1 NOTE: It is recommended that all fasteners be stainless steel. 1. Using the installation template (W122-0401) supplied, determine the best mounting location for your new T orch.
9 W415-0689 / 06.25.08 RAIN T ABS DOOR REMO V AL GLASS REMO V AL Having removed the door , lay on a smooth fl at surface, face down. There are 4 glass retainers that need to be bent away from the glass to release it from the frame. Do not pry on the glass.
10 W415-0689 / 06.25.08 2. Install the trim bracket supplied in your manual baggie to the fi rebox using 3 screws. DOOR CHAIN SLOT FRAME (REAR VIEW) TRIM BRACKET 1/4” ( APPROX.) CONTROL DOOR 1/4” ( APPROX.) With the control door closed, af fi x the logo to the front face of the control door at the bottom left corner .
11 W415-0689 / 06.25.08 LK8 LIGHT INST ALLA TION (OPTIONAL) 1 . T urn off the electrical and gas supply to the appliance. 2 . Remove the frame from the unit by removing the the 2 stainless steel hex head securing screws from the bottom and lifting the frame off of the top trim bracket.
12 W415-0689 / 06.25.08 O S A A. This appliance is equipped with an ignition device which automatically lights the burner . Do not try to light by hand. B. Before operating, smell all around the appliance area for gas and next to the fl oor because some gas is heavier than air and will settle on the fl oor .
13 W415-0689 / 06.25.08 Closing the air shutter will cause a more yellow fl ame, but can lead to carboning. Opening the air shutter will cause a more blue fl ame, but can cause fl ame lifting from the burner . The flame may not appear yellow immediately; allow 15 to 30 minutes for the fi nal fl ame color to be established.
14 W415-0689 / 06.25.08 # P ART NO. DESCRIPTION 1 W225-0223 DOOR FRAME 2* W562-0008 DOOR GASKET 3 W010-1959 GLASS C / W GASKET 4* W300-01 10 GLASS 5 W100-01 1 1 BURNER 6 W357-0006 IGNITOR 7 W190-0026 .
15 W415-0689 / 06.25.08 TR OUBLE SHOO TING GUIDE BEFORE A TTEMPTING TO TROUBLESHOOT , PURGE YOUR UNIT AND INITIALL Y LIGHT THE IGNITOR AND THE MAIN BURNER WITH THE GLASS DOOR REMOVED.
16 W415-0689 / 06.25.08 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Napoleon Fireplaces GSST8P è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Napoleon Fireplaces GSST8P - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Napoleon Fireplaces GSST8P imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Napoleon Fireplaces GSST8P ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Napoleon Fireplaces GSST8P, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Napoleon Fireplaces GSST8P.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Napoleon Fireplaces GSST8P. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Napoleon Fireplaces GSST8P insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.