Manuale d’uso / di manutenzione del prodotto 1400 del fabbricante Napoleon Fireplaces
Vai alla pagina of 20
1 W415-0512 / B / 1 1.15.05 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.
2 W415-0512 / B / 1 1.15.05 PG 2 - 4 INTRODUCTION Warranty General Information Care of Plated & Enamelled Parts Care of Glass 5- 6 INST AL LA TION Installing the Legs Alcove Installation S tove In.
3 W415-0512 / B / 1 1.15.05 NAPOLEON products are manufactured under the strict Standard of the World Recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0512 / B / 1 1.15.05 Except for their different depths, models 1 100, 1 150, 1400, 1900 and the fireplace inserts 1 101 and 1401 are identical and use the same burning principles. They were specifi- cally designed over many months of research to meet the 1990 U.
5 W415-0512 / B / 1 1.15.05 To avoid being damaged during shipping, the stove has been bolted to the pallet and must be unbolted before the stove can be installed. 1. Remove the 4 nuts and washers from the underside of the pallet. 2. Lift the stove up and away from the pallet to clear the threaded studs sticking through the pallet.
6 W415-0512 / B / 1 1.15.05 PEDESTAL BASE 4.5" PEDESTAL BASE FLOOR AREA BELOW STOVE A" B" A (in.) B(in.) 1 100 8 5/8" 9 3/4" 1400 1 1 1/8" 9 3/4" 1900 14 7/8" 9.
7 W415-0512 / B / 1 1.15.05 It must be installed be- tween ceiling joists, with radiation shield and roof flashing, so that the structural strength, insulation and waterproof quali- ties of the home are not lessened. Seal with silicone to maintain a vapour barrier at the chimney and outside air pipe penetrations.
8 W415-0512 / B / 1 1.15.05 In the United States: While it is not required, it is rec- ommended that a chimney liner be installed that is con- tinuous from the insert to the top of the chimney , particu- larly when the insert is installed in a basement.
9 W415-0512 / B / 1 1.15.05 3. The access panel can be removed by taking out the 8 #10 self taping screws. A 5/16" nut driver will be required to complete this job.
10 W415-0512 / B / 1 1.15.05 1 100/1 100C/ 1101 1400/1400L 1401 1900 1 100L/1 150 4-#1 4-#1 4-#1 4-#1 4-#7 * 2-#4 2-#4 2-#4 2-#4 2-#2 8-#1 8-#1 12-#1 12-#1 12-#7 * 2-#3 2-#3 2-#3 2-#4 (notched) 2-#10 .
11 W415-0512 / B / 1 1.15.05 With stove and chimney installation completed, move the bricks into place by working as illustrated for your unit on page 10. 1. Install two or three courses of brick on both sides of the unit. Install two courses on the back wall.
12 W415-0512 / B / 1 1.15.05 ASH W ELL COVER ROTATE TO CLOSE: FOLDING HANDLE REAR ROTATE PULL AND TO O PEN: Y ou can now add larger pieces of wood and operate the stove normally . Once the stove/insert is entirely hot, it will burn very efficiently with little smoke from the chimney .
13 W415-0512 / B / 1 1.15.05 A properly installed Napoleon unit should not smoke. If yours does, check the following: Has the chimney had time to get hot? Is the smoke passage blocked anywhere in the stove, chimney connector or chimney? Is the room too airtight and the air intake not connected to the outside? Try with a window partly open.
14 W415-0512 / B / 1 1.15.05 Burn only dry , clean unpainted wood that has been seasoned. It produces more heat and less soot or creosote. Freshly cut wood contains about 50% moisture while after proper sea- soning only about 20% of the water remains.
15 W415-0512 / B / 1 1.15.05 # P AR T NO . DESCRIPTION 1 W325-0002 SPRING HANDLE - SMALL 2 W325-0007 SPRING HANDLE - LARGE 3* W090-0001 BRICK - # 1 4* W090-0002 BRICK - # 2 5* W090-0004 BRICK - # 4 LE.
16 W415-0512 / B / 1 1.15.05 6 5 GS200-G ORNAMENT A L TRIVET 6 6 EP62-1 V ARIABLE SPEED BLOWER 67* W500-0064 FRESH AIR COVER PLA TE 68* 1 1 1 K T OUTSIDE AIR KIT 69* W470-0002 ENAMEL TOUCH UP & BR.
17 W415-0512 / B / 1 1.15.05 59 15 16 18 17 19 16 57 2 32 12 10 14 30 33 74 31 44 84 83 73 72 76 63 64 Z.P. Ins. ClassB 115V 60Hz 46W EM3030L-167 zr-2 073 SEL 81 66 1 46 77 40 38 39 58 65 55 56 48 49 .
18 W415-0512 / B / 1 1.15.05 W olf Steel Fireplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Deale.
19 W415-0512 / B / 1 1.15.05 NO TES.
20 W415-0512 / B / 1 1.15.05 NO TES.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Napoleon Fireplaces 1400 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Napoleon Fireplaces 1400 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Napoleon Fireplaces 1400 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Napoleon Fireplaces 1400 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Napoleon Fireplaces 1400, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Napoleon Fireplaces 1400.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Napoleon Fireplaces 1400. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Napoleon Fireplaces 1400 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.