OPERATING GUIDE FOR YOUR MAGNUM ALEm-800/800s SECURITY SYmM 01955 NAPCO.
You have taken a major step in protecting your home or busi- ness by having a Napco Magnum Alert-800/800S Alarm Control Center installed. Please read this guide thor- oughly to familiarize yourself with your new security system. Keep this booklet handy for future reference.
A delay period that allows the system to be reset before it reports to a cantml station. AlmmPlmn Identifies the areas of tected by each zone o r our premises pro- protection and lists zone features (see page 15). Anrrkrg/- Turning yours tern ON or OFF.
lndlcator ughts -/-n=Y wm 1-1 l Steady - system is armed. l Flashes - system is in alarm. Count the number of flashes to tell in which zone the alarm occurred. Example: Fourflashes- alarm in Zone 4. smU9Mf-l l Steady - system is disarmed, all zones okay.
Each security system is custom tailored to the owner’s needs, but all MAGNUM ALERTBOO/ 800s have the following: 1. zones 2.lhdMg~KayKeypad f.TheAIammOutput Your system contains up to six f=Wkay_J When any zone is activated, separate zones.
uslrBgyourcdetoaml addiurmtheqs8mm If your system includes the Once you enter your personal Napco Digit-Key keypad you can code into the Napco Digit-Key choose your own private code keypad, the red ARMED/MEMORY to arm and disarm the Control light will go on to show the Control Center.
First, check the green STATUS light at the keypad or keyswitch. If this light is on stead- ily, enter your code. The red ARMED/MEMORY light will come on and the green lamp will go out. Leave immediately through the entry/exit doorway before the delay time runs out.
SHUNT button, labeled “S”, and enter your code. The yellow SHUNT light and the red ARMED/ MEMORY light will come on. The green light will be out. All zones programmed by your alarm spe- cialist to respond to manual shunting will be shunted (even if some are not in “trouble”).
Arming with zone shunting You might have chosen one or two zones that you can man- ually “shunt out” of the system from the keypad. A shunted (bypassed) zone cannot cause an alarm. Zone shunting may be used for turning off interior protection, or allowing you to turn on only your perimeter protection.
Panic alarm To activate a panic alarm and call for outside help, press the two buttons marked l and # on the Digit-Key keypad. Makesure you press both buttons at the s8me time. The panic zone is capable of sending asilent signal to the Central Station when a Digital Communicator is being used (optional).
Your Alarm Specialist may have programmed your security system to be monitored by a Central Station. The built-in digital communicator can trans- mit emergency signals to the Centml Station 24 hours a day.
AbortDeby Note which zones on your Cantfal Madon alarm plan have abort delay. This mribwk is a 16 second delay that enables The Central Station will ac- An optional feature that per- you to reset the .
The following information is applicable only where local ordinance permits use of your alarm Control Center for fire detection Controrlklg Your Fin Circuit If your alarm specialist installed smoke detectors or heat sensing thermostats, you have 24 hour fire protection.
an escape plan Even with the most advanced fire alarm system, adequate pro- tection requires an escape plan. To prepare your plan: Draw floorplans of your build- ing (see sample). Show two exits: a front or back door and a window from each room. (Make sure the window works.
Zone Area Protected Zone Features Contacts (doors, windows, etc.) 1 3 I 4 I Aux. (6) Central Station? Service Person ‘optlonal katun, Telephone# , Telephone# 15.
NAPCOLlMiTEDWARRANly.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Napco Security Technologies 800S è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Napco Security Technologies 800S - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Napco Security Technologies 800S imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Napco Security Technologies 800S ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Napco Security Technologies 800S, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Napco Security Technologies 800S.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Napco Security Technologies 800S. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Napco Security Technologies 800S insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.