Manuale d’uso / di manutenzione del prodotto MGT16 del fabbricante Nady Systems
Vai alla pagina of 16
M GT - 16 OWNER’S MANUAL 16-Channel Mini UHF Wireless Instrument System.
Contents 2 Introduction ............................................................................................................................. 2 Using this Manual .................................................................................
System Features MGT -16 System Features UHF wireless system for guitar/bass • 16 user -selectable PLL frequencies • for interference-free operation Up to 250’ operating range, line-of-sigh.
4 Quick User Controls Guide MGT -16 Instrument Receiver POWE R AC T 10 13 14 11 12 2 1 3 6 5 15 IR PO LO RX LEVE L CHANNE L 1 234 SQ OFF ON 7 8 9 16 4.
1. ASC ™ IR SYNC INFRARED LED WINDOW For downloading selected Channel (Frequency) to transmitter 2. POWER SWITCH Select OFF/MUTE/ON (MUTE=power On, audio out put highly attenuated) 3. VOLUME CONTROL Adjusts the audio output level — at maximum setting the gain will be about +4dB over a direct instrument-to- cord-to-amp connection 4.
6 Quick User Controls Guide MT -16A/R Instrument T ransmitter 17. POWER SWITCH T o power transmitter Off/On 18. 15dB A TTENUATION P AD Select to r educe the input gain b y 15dB for hi gher level au dio input signals 19. INPUT ¼” PLUG Connect directly into guitar/bass output jack 20.
7 IR Sync Selected Frequency Download from MGT -16 Receiver to MT -16A/R T ransmitter (1) ASC ™ IR SYNC INFRARED LED WINDOW For downloading selected Channel (Frequency) to transmitter (21) IR RECEPTOR SENSOR/WINDOW Infrared LED sensor for l inking the TX to the RX du ring IR frequency download.
powers the u nit and will not charge Ni MH rechargeable batteries if installed. F or battery operation the AC adapter must be disconnected. Note: For quietest optimal perf ormance, use the AC/DC adapter as battery operation raises the noise floor around 4 dB.
9 When the RF Signal LED (10) on the rec eiver lights up, the system frequency is properly synchronize d. T o change to a different frequency , reset the Frequency Select DIP Switches (4) and sync t he transmit ter again to the new selected frequency first, after turning the transmitte r off and th en on again.
10 trim-pot counterclockwise reduces overall system audi o output (t hus lowering distortion but raising background noise), while turning clockwise increases overall system audi o output (t hus lowering background noise but r aising disto rtion).
11 Specifications MGT -16 SYSTEM Frequency Response 50Hz–16kHz (-3dB) Dynamic Range 120dB Oscillating System Phase Lock Loop (PLL) T otal Harmonic Distortion (THD) <0.
Cautions and T roubleshooting 12 No or Low Audio If you are not getting audio through the system, carefully re-check all setups. Especially note that the receiver and transmitter must be set to operate on the same RF channel.
13 Miscellaneous T ips The receive r antennas should be ke pt • away from a ny metal su rfaces whene ver possible as they can r eflect away o r shield the incoming RF signal. When insert ing batteri es, make sur e they • are inserte d with the correct pola rity .
14 MGT -16 DIP-Switch Frequency Selection Chart Frequency Plan: 902.4MHz-923.7MHz (16 Channels) U.S. Channel Selection Frequency 9 913.9 10 914.0 11 916.0 12 917.9 13 919.7 14 920.0 15 921.1 16 923.7 Channel Selection Frequency 1 902.4 2 904.8 3 905.4 4 906.
15 One-Y ear Limited Warranty Nady Systems , Inc. warran ts to the ori ginal consume r purchaser t hat the unit is free from any defects in material or workmanship for a period of one year from the date of original retail purchase. If any such defect is discovered within the warranty period, Nady Systems, Inc.
6701 Shellmound Street | Emeryville, CA USA 94608 T 510.652.2411 | F 510.652.5075 | www .nady .com.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Nady Systems MGT16 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Nady Systems MGT16 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Nady Systems MGT16 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Nady Systems MGT16 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Nady Systems MGT16, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Nady Systems MGT16.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Nady Systems MGT16. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Nady Systems MGT16 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.