Manuale d’uso / di manutenzione del prodotto 105FX-POE del fabbricante N-Tron
Vai alla pagina of 19
Rev. 041008 1 105TX-POE & 105FX-POE Unmanaged Ind ustrial Ether net POE Switches User Manual & Installation Guide.
Rev. 041008 2 Industrial Power over Et hernet Installation Guide 105TX-POE 105FX-XX-PO E 105FXE-XX-Y Y-POE Where: XX = ST or SC and YY = -15, -40, or -80.
Rev. 041008 3 Copyright, © N-TRON Corp., 2 008 820 S. University Blvd., Suit e 4E Mobile, AL USA 36609 All r ights reser ved. Rep roduction, adaptation, or trans lation withou t prior written permission from N-TRON Corp. is prohibited, exc ept as allowed under copyright laws .
Rev. 041008 4 GENERAL SAFETY WARNI NGS WARNING: Do not operate the e quipment i n the presence of flammable gasses or fumes. Operati ng electrical equipment in such an environment constitutes a definite safety hazard. WARNING: If the e quipment is used in the manner n ot specified by N-TRON Corp.
Rev. 041008 5 HAZARDOUS LOCATI ON INSTALLATION REQUIREM ENTS 1. This equi pment is su itable for use in Cl ass I, Div 2, Gro ups A, B, C, and D, or unclassified or non- hazardous locations only . 2. WARNING: Explos ion Hazard - Substitution of co mponents may impair suitabili ty for Class I, Division 2.
Rev. 041008 6 Functional Overview The 105TX-POE and 105FX- POE Power over Ethernet Unman aged Industrial Ethernet Swit ches are designed to provide power ove r Ethernet for POE capable devices where running a power line is either no t possible or not cost effecti ve.
Rev. 041008 7 PACKAGE CONTENTS Please make sure the switch package contains the following items: 1. 105TX-POE or 105FX(E) -POE 2. Instruction Sheet Contact your carrier if any it ems are damaged. UNPACKING Remove all the equipment from the packaging, and stor e the packaging in a safe place.
Rev. 041008 8 DIN-Rail Mounting Install the unit in a standar d DIN rail. Recess the unit to allow at least 2” of horizontal clearan ce for CAT5e cable bend radius. To inst all the u nit to 35mm industrial DIN rail, place the top edge of the includ ed mounting bracket on the back o f the unit against the DIN rail at a 15° angle as shown.
Rev. 041008 9 FRONT PANEL From Top to Bottom : Power LED POE POE Status LED SPD Speed LED (105TX-POE on ly) LNK/ACT Link/Activity LED RJ45 Ports Auto sensi ng 10/100BaseT Connection LED MODE OF OPERATION Note: Redundant po wer inputs will not balance the power load.
Rev. 041008 10 APPLYING POWER (To p View) Unscrew & Remove the DC Volt age Input Plug from the top header. Install the DC Power Ca bles into the Plug (obse rving polarity on unit). Plug the Voltage Input Plug ba ck into the top header. Tightening torque for the te rminal block power plug is 0.
Rev. 041008 11 N-TRON GROUNDING TECHNIQUES FOR 105 TX-POE AND 105FX-POE The grounding philosophy of any control system is an integral part of the design. N-Tron switches are designed to be gro unded, but the us er has been given the flexi bility to float the switch when required.
Rev. 041008 12 RJ45 CONNECTOR CRI MP SPECIFICATIO NS Please reference the illustrati on below for your Cat5 cable specificati ons:.
Rev. 041008 13 TYPICAL APPLICATIO NS STAR TOPOLOG Y.
Rev. 041008 14 RING TOPOLOGY.
Rev. 041008 15 CONNECTING THE UNIT For th e 100BaseFX Fiber Optic port (105FX- POE), remove the dust cap(s) from the fiber optic connec tor and connect the fiber optic cables. The TX por t on th e local unit should be connected to the RX port of the far en d device, and the RX port sho uld be connected to the TX port of the far end device.
Rev. 041008 16 FCC STATEMENT This product complies with Pa rt 15 of the FCC-A Rules. Operation is subject to the following conditions: (1) This device may not cause har mful interference (2) This device must accept a ny interferenc e received, including interference that may cause undesired operation.
Rev. 041008 17 Regulatory Approvals: Safety: UL Listed per ANSI/ ISA-12.12.01-2000 (US an d Canada) This apparatus is suita ble for use in Class I, Div 2, Groups A, B, C, D, T 4 EMI: EN 61000-6-4 , EN.
Rev. 041008 18 KEY SPECIFICATIONS Physical Height: 3.50” (8.89 cm.) Width: 1.50” (3.81 cm.) Depth Including Din- Rail Clip: 4.22” (10.72 cm) Weight: 0.70 lbs. (0.32 kg) Electrical Input Voltage: 46-49 VDC Input Current: 1.6 A @ 48 VDC (under ful l load) 65 mA @ 48 VDC (no POE in use, switch in full use) Inrush Current: 26 Amp/1.
Rev. 041008 19 N-TRON Limited Warranty N-TRON, Corp. warrants to the end user that this hardware product will be fr ee from defects in workmanship and materials, under normal u se and service, for the applicable warranty perio d from the date of purchase from N -TRON or its authorized reseller.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il N-Tron 105FX-POE è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del N-Tron 105FX-POE - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso N-Tron 105FX-POE imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul N-Tron 105FX-POE ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il N-Tron 105FX-POE, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del N-Tron 105FX-POE.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il N-Tron 105FX-POE. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo N-Tron 105FX-POE insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.