Manuale d’uso / di manutenzione del prodotto 40-01459-D0-001 del fabbricante Multi-Tech Systems
Vai alla pagina of 63
EnterpriseExpress Adapter/ESCON INSTALLATION GUIDE Insta llation Guid e Part Number 40-01459-D0-001 129 Middlesex Turn pik e, Burlingt on Ma. 01803 • (781) 272- 8200 Fax (781) 272- 0342 • www.
Fe deral Comm unicat ions Comm ission (FCC) Stat ement WARN I NG: This equip ment generat es, uses, and can radi ate radio frequ enc y energy and if not installed and used in a ccordance with the instruction ma nual, may cau se interference to radio communications.
Table of Contents i Table of Contents • • • •• • • •• • • •• • • • A BOUT T HIS P UBLICATION ............................. iii Who Should Use This Publication ................... iii How t o Use This Publica tion ......
.
About This Publication iii About This Publication This User's Guide provides the information necess ary to install and configure Bus- Tech's PC I ESCON Ada pter (PBSA) t o connect a Server to an IBM Mainf rame.
iv PCI ESCON Adapter Installation Guide CHAPTER 6. TROUBLESHOOT ING – This chapter t akes the read er through some troubleshooting steps to be tried when the adapter is not working properl y. What’s Ne w in th is Release ? Plug and Play drivers for Microsoft W indows 2000 Server have been adde d to the installation kit.
Introduction 1 Chapter 1. I NTRODUCTION The PCI ESCON Adapter from Bus-Tech, Inc. is a high performance adapt er that enables PCI-based sy stems to communicate with mainfra me systems through direct IBM channel attachment.
2 PCI ESCON Adapter Installation Guide Additionally, the PCI ESCON Adapter includes TCP/IP Direct Connect fo r the Windows 2000 and NT environments. Direct Connect provides a hi gh-performance, point-.
Introduction 3 Minimum System Requirem ents Hardw are The minimum hardware requirements fo r using the PCI ESCON Adapter are: - Pentium 100Mhz - 64MB RAM for Windo ws NT Systems -128MB RAM for Windows.
.
Hardware Installa tion 5 Chapter 2. H ARDW ARE I NST ALLA TION Ins talling the Ada pter CAUTION! The PCI ESCON Adapter is a PC adapter card and as such can be damaged by Electrostatic Discharge. Before removing the adapter from it’s protective static bag, please ensure that you are free of static char ge.
6 PCI ESCON Adapter Installation Guide 4. Remove the adapter from its protective anti-static bag and insert the adapter into the chosen PCI bus slot. Make sure the adapter is fully inserted in the slot. Place a screw throug h the top of the mounting bra cket and secure ly fasten to the sy stem chassis.
Driver Insta llation 7 Chapter 3. D RIVER I NST ALLA TION The PCI ESCON Adapter offers driv ers for Micro soft's Windows 2000 Server and Microsoft Windows NT Server. This chapter disc usses installation of the drivers. Please refer to the section appropria te to your operating environment.
8 PCI ESCON Adapter Installation Guide Figure 3-2. Search the Floppy The hardware wizard will search the W indows director y and then the floppy disk. When it finds the PBSA drivers it will prompt you for approval to install (Fig ure 3-3). Figure 3-3.
Driver Insta llation 9 Figure 3-4. New Found Hardware Wizard Completing.
10 PCI ESCON Adapter Installation Guide Windows NT The PBSA network driver is alwa ys required in order to allow Windows NT to communicate with the adapter . The d river must be installed once for each PC I ESCON Adapter installed in the system. The following step-b y-step procedure will install the driver into your Wi ndows NT Server.
Driver Insta llation 11 Figure 3-6. Network Screen 3. From the Select N etwork Adapter screen (Figure 3-7), click t he H ave Disk... button. Figure 3-7.
12 PCI ESCON Adapter Installation Guide 4. The Insert Disk screen i s displayed (Figure 3-8). Figure 3-8 . Insert Disk Dialog Box With the floppy inserted into the flopp y drive point to the root director y by enterin g " A: " wher e A is y our flopp y drive and press O K .
Driver Insta llation 13 Figure 3-10. ESCON Configuration 7. As shown in Figure 3-11, the adapter should now be listed in the N etwork Adapters box . C licking Close will cause the system to configure the network and prompt you to restart the system. Figure 3-11.
.
ESCON Configuration 15 Chapter 4. ESCON C ONFIGURA TION Figure 4-1. ESCON Attached Controllers Overvie w ESCON controllers, including the PCI ESCON A dapter (PBSA) , can be co nnected to the mainframe in more than one fashion. As show n in Figure 4-1, Controller 1 is attached directl y to one of the mainfram e’s ESCON channels.
16 PCI ESCON Adapter Installation Guide Finally, using both ESCON Directors and EMIF, it is possible for a single ESCON controller to communicate with multiple Logical Partitions ( LPARs) running on multiple mainframes, using multiple ESCON channe ls.
ESCON Configuration 17 Channel Link – The address of the ESCON director port that conne cts to the mainframe this device is to communicate with. The va lue range is from 01-FE hexadecimal. In Figure 4-2 the mainfram e uses a channel link address '02 ' to communicate with S erver 1.
18 PCI ESCON Adapter Installation Guide Configur ation ESCON configuration may be defined and viewed from an y of the upper level software including the data link service for Micros oft’s Host Integration Server or SNA Server, data link control for Communications Server, TCP/ IP Passthrough, TCP/IP Direct Connect, or MPC+ for Windows.
ESCON Configuration 19 In Windows NT the ESCON configuration ma y be accessed through the system Control Panel. From the main screen of Control Panel double click the Network Ic o n (See Figure 4-4). Figure 4-4. Windows NT Control Panel Select t he Adapters tab (Figure 4-5).
20 PCI ESCON Adapter Installation Guide The Bus-Tech PCI ESCON Adapter should be included in the list. Selecting the Bus-Tech ada pter and clicking P roperties will bring up the E SCON Configuration Screen (Figure 4-6). Figure 4-6. Bus-Tech’s ESCON Configuration Screen To configure a new d evice click A dd… Figure 4-7.
ESCON Configuration 21 device A0 and A1, enter 2. Optionall y e nter a Descripti on to be associated with this device. Remember that for TCP/ IP Passthrou gh and TCP/IP Direct Connect CTC c onnections you must define two con secutive devices. Additionally for TCP/ I P Passthrough the first device must be even numbered (00, 02, 20, 4 0, A0, etc.
.
TCP/ IP Direct Connect 23 Chapter 5. TCP/IP D IRECT C ONNECT TCP/IP Direct Connect s oftware included with the P CI ESCON Adapter p rovides high-performance, point-t o-point TCP/I P communications between a Windows server (Windows 2000 or W indows NT 4.
24 PCI ESCON Adapter Installation Guide TCP/IP Direct Connect supports three link types across the ESCON channel: Channel-to-Channel (CTC), Hig h-Speed Access Services (HSAS) for UDP, or Multi- Path Channel Point-to-Point (MPCPTP). HSAS and MPCPTP require installation of MPC+ for Windows (MPC+).
TCP/ IP Direct Connect 25 2. Click OK when Setup display s it’s W elcome dialog (Figure 5-4). Figure 5-4. TCP/IP Direct Connect Install Confirmation 3.
26 PCI ESCON Adapter Installation Guide defined by the install you have just completed. Right click the connection and select Pro pe rt ie s (Figure 5-7).
TCP/ IP Direct Connect 27 7. Enter an IP address and Subnet mask to be associated with this link on the server. This is the address a mainframe-based application will use to establish contact with the Windows 2000 server (Fi gure 5-9). The address must be i n the same IP subnet as the address assigned to this link on the mainframe.
28 PCI ESCON Adapter Installation Guide Deleting a Link To remove a previousl y installed TCP/I P Direct Connect link from Windows 2000, y ou must uninstall the TCP/I P Direct Connect Adapter. This is accomplished using the Device Manager in the Windows 2000 Computer Management utilit y (Figure 5-10).
TCP/ IP Direct Connect 29 Windows NT The following step-b y-step procedure will in stall the TCP/ IP Direct Connect and configure it for use without MPC+. Installation a nd configuration of TCP/IP Direct Connect using MPC+ is discussed in the “ MPC+ for W indows NT Installation Guide ”.
30 PCI ESCON Adapter Installation Guide Figure 5-12. Adapter List with ESCON Adapter 3. Click the A dd button to add a new adapter. The Select Network Adapter dialog box will display a list of adapters includ ed with Windows NT (Figure 5-13.). Figure 5-13.
TCP/ IP Direct Connect 31 Figure 5-14.Insert Disk 5. Insert the TCP/I P Direct Connect diskette into your floppy. Click OK . 6. The Select OEM Option dialog (Figure 5-15) will display TCP/IP Direct Connect. Click OK to install the driver. Figure 5-15.
32 PCI ESCON Adapter Installation Guide Figure 5-16. Adapter Properties You must define the Link type and L ink p roperties in order to complete the install.
TCP/ IP Direct Connect 33 9. Click on Bindings. Show bindings for all adapters (Figure 5-18). Check that only the TCP/IP Protocol is bound to the TCP/IP Direct C onnect Adapter. Disable an y other service or protocol bound to TCP/IP Direct Connect. Figure 5-18.
34 PCI ESCON Adapter Installation Guide 11. Use your mouse to select TCP/I P Direct Connect from the list of Adapters bound to TCP/IP (Figure 5-20). Figure 5-20. Select TCP/IP Direct Connect 12. Enter an IP Address and Subnet Mask; defining the address that the mainframe will use to communicate with the server (Fi gure 5-21).
TCP/ IP Direct Connect 35 Figure 5-21. Assigning an IP Address to the ESCON Adapter 13. Click OK . Windows NT will complete the binding process and prompt y o u to reboot the server. You m ust reboot for network ch anges to take affe ct. Insta llation of TCP/I P Direc t Connect is complete.
36 PCI ESCON Adapter Installation Guide Link Configuration Figure 5-22. CTC Link Properties Figure 5-22 shows the pr operties that must be con figured for CTC Links. Complete these fields as follows: Mainframe I P Address – The IP address of the mainframe this connection is to communicate with .
TCP/ IP Direct Connect 37 MTU – Maximum Transmission Unit must match what is def ined on the mainframe for this conne ction or packet loss will occur. Th e recommended MTU for CTC connections is 32000. To configure MPC+ links, either HSAS or MPCPTP, please refer to the MPC+ for Windows Installation Guide.
38 PCI ESCON Adapter Installation Guide Mainf ram e Configu ration This section discusse s configuration of the ma inframe for use with TCP/IP Direct Connect over a Channel-to-Channel (CTC) link.
TCP/ IP Direct Connect 39 TC P/I P Pro f il e TCP/IP Direct Connect links require the IBM TCP/ I P protocol stack running on y our System/390. Your TCP/ IP Profile will need to be modified to support the new link.
40 PCI ESCON Adapter Installation Guide Figure 5-23. Multiple TCP/IP Direct Connect ESCON Configuration *** CHPID STA TEMENTS *** CHPID PATH=((22 )),TYPE=CNC ,SWITCH=01,SHARED *** CNTL UNIT STATEMENTS.
TCP/ IP Direct Connect 41 TCP/IP R outing TCP/ IP Direct Connect i s a Network Driver Interface Spe cificati on (ND IS) compl iant adapter driver. TC P/IP Direct Connect makes t he PCI ESCON Adapt er appear exactl y like any other Network Interfac e Card (N IC) to the Windows server.
42 PCI ESCON Adapter Installation Guide Subnet 0 207.168.12.1 – 207.168.12.62 Subnet 1 207.168.12.65 – 207.168.12.126 Subnet 2 207.168.12.129 – 207.168.12.190 Subnet 3 207.168.12.193 – 207.168.12.254 As shown, the Ethernet segment makes up subnet 0 and the Token-Ring makes up subnet 1.
TCP/ IP Direct Connect 43 Figure 5-26. TCP/IP Direct Connect Configuration Screens Notice also that the subn et these two addr esses are in is different than the subnet of the server’s LAN adapter (207.
44 PCI ESCON Adapter Installation Guide Updating Workstat ion Configurations In most existing networks today it will not be necessary to update the TCP/I P configuration on a workstation in order to allow it to connect to the mainframe using an ESCON adapter and TCP/I P Direct Connect.
TCP/ IP Direct Connect 45 Figure 5-28. Windows 95 TCP/IP Properties.
.
Troubleshooting 47 Chapter 6. T ROUBLESHOOTING If your PCI ESCON Adapter fails to initiate successfully this ch apter will provide y ou with some general troubleshooting guidelines to help you identify and fix your problem.
48 PCI ESCON Adapter Installation Guide STEP 1. With y our server powered on, check to ma ke sure both LEDs are lit. If the top LED is Green and the bottom LED is Oran ge then the adapter h as successfull y completed POST and loade d firmware. This is the normal condition prior to starting the software.
Troubleshooting 49 ESCON Configuration When the adapter loads t he emulation it also loads the ESCON device con figuration (see Chapter 4.). This configuration must match the configuration defined on your mainframe(s).
50 PCI ESCON Adapter Installation Guide Highlight the ESCON adapter and click P roperties. Figure 6-3. ESCON Device Configuration The ESCON Devices tab shows the devices confi gured for this adapter. Verify that the units defi ned here m atch those defined on the mainframe.
Troubleshooting 51 TCP/IP Direct Connect If TCP/ IP Direct Connect is configured with a link type of HSAS or MPCPTP, please refer to the section titled “Troubleshooting” in the “ MPC+ for Window s NT Installation Guide ”.
52 PCI ESCON Adapter Installation Guide Figure 6-5. TCP/IP Direct Connect Properties ; CTC connection DEVICE DEVCTC1 CTC a40 LINK LINKCTC1 CTC 0 DEVCTC1 ; HOME 207.169.12.129 LINKCTC1 GATEWAY ; ; Direct Routes - Routes that are directly connected to my interfaces.
Help and Servic e Informat ion 53 Help and Service Information If you have questions about y our new Bus-Tech p roduct, or require technical assistance, visit the Bus- Tech Web site at http:www.
54 PCI ESCON Adapter Installation Guide If possible, be at your computer. Your technical support repres entative might want to walk you through the problem during the call. Step 3: Placing the Call If you call after your warranty or maintenance con tract has expired, you might be charged a f ee.
Help and Servic e Informat ion 55 Custom er Response If you have comments or suggestions regarding our products and documentation, please send them to: BUS-TECH, I NC. 129 MIDDLESEX TURNP IKE BURLINGTON, MA 01 803 ATTENTION: CUSTOMER SUPPORT Or, call us at: (781) 272 -8200 FAX: (781) 272-0342.
.
Technical specifi cations 57 Technical S peci fications Physical Attributes Dimensions Standard Full Siz e PCI A dapter Length 12.283” Height 4.2” Power Requirements 5.5 Amp. at + 5V DC 20 mAmp. at + 12V DC 20 mAmp. at - 12V DC Operatin g Temperat ure 10 o -4 0 o C Humidity Range 0% - 90% Standards PCI 2.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Multi-Tech Systems 40-01459-D0-001 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Multi-Tech Systems 40-01459-D0-001 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Multi-Tech Systems 40-01459-D0-001 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Multi-Tech Systems 40-01459-D0-001 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Multi-Tech Systems 40-01459-D0-001, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Multi-Tech Systems 40-01459-D0-001.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Multi-Tech Systems 40-01459-D0-001. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Multi-Tech Systems 40-01459-D0-001 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.