Manuale d’uso / di manutenzione del prodotto EM316T1 del fabbricante MRV Communications
Vai alla pagina of 23
EM316 T 1 EM316 E 1 Fiber Driver Modem User’s Guide.
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PA GE 2 Registration Card Your name: Mr./Ms____________ _______________________________ Organization: _________________ _______Dept.
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PA GE 3 EM316E1 EM316T1 Fiber Driver Modem User’s Guide.
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PA GE 4 TABLE OF CONTENTS 1 INTRODUCTION 2 HARDWARE INSTALLATION 3 TROUBLESHOOTING 4 TECHNICAL SPECIFICATIONS 5 CONTACT INFORMATION 6 GLOSSARY 7 OR.
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PA GE 5 1 INTRODUCTION About this Manual Before unpacking please refer to section 2 (Hardware Installation) This manual is a guide to the installa tion and operation of the EM316E1/T1 Fiber Modem.
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PA GE 6 Features • Modules can be Inserted / Removed without powering off the chassis • Extensive Network Management Support when used with EM316NM • Provide Fiber Link for T1(ANSI T 1.403) or E1 (G.
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PA GE 7 Connectivity Connectors Used Fiber: ST, or SC-APC (for single fiber) UTP: RJ48-MDI Coax: BNC (2 connectors: 1 for TX, 1 for RX) Cable Requi.
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PA GE 8 Display Information (LED Definition) • PWR/NMS: illuminates when unit is powered (green colo r), flashes (green color) when remote or local loop back is enabled by management.
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PA GE 9 Typical Applications EM316E1/T1 (Fiber Modem).
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 10 Configuration Jumper Settings: (Factory Default) DO NOT CHANGE THE JUMPER SETTINGS BELOW JUMPER SETTINGS RESULTS JP2 OPEN Factory Use Only .
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 11 EM316E1 Jumper Settings for E1 120 Ω Application : 1) Install jumpers between JP3 pins 1 and 2, 2) No jumpers on JP4 and JP5 open, (all pi ns are open) 3) Set all switches on S1 to ON.
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 12 EM316E1 Jumper Settings for E1 75 Ω Application : 1) Install jumpers between JP3 pins 3 and 4, 2) Install jumpers between JP4 pi ns 1 and 2, JP5 pins 1 and 2 3) Set all switches on S1 to ON.
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 13 EM316T1 Jumper Settings for T1 100 Ω Application : 1.) Install jumpers between JP3 pins 1 and 2, 2.) No jumpers on JP4 and JP5 open, (all pi ns are open, no headers, not used) 3) Set RECEIVED CODE and TRANSMIT CODE on S1 to ON.
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 14 Theory of Operation Data encoding used on the EM316E1/T1 Fiber Modem consists of converting the incoming AMI B8ZS or HDB3 to a format suitable for fiber optic communication.
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 15 2 HARDWARE INSTALLATION PREP ARA TION STEP 1 Follow all Safety Regulations 1 Eliminate static electricity in the workplace by grounding operators, equipment, and devices (components and computer boards).
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 16 f) ESD protective floor or mat: The mat must be grounded through a current- limiting resistor.
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 17 UNIT INSTALLATION STEP 1 Remove required amount of bla nk panels from the NC316BU-xx. NOTE : Per FCC regulations, either a panel or a module should always cover chassis slots. FIGURE 1.1 Take out the required amount of blank panels.
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 18 STEP 3 Insert the module into the NC316BU-xx unit NOTE: To avoid damaging any components on the m odule, handle it by the edges, using your thumb to push it securely inside the ch assis. Do not use excessive force, but make sure the module is fully inserted in the chassis.
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 19 3 TROUBLESHOOTING The Fiber Driver series are highly reliable units. If there are any operating problems, the fault probably lies in some other aspect of the configuration.
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 20 4 TECHNICAL SPECIFICATIONS Electrical 5VDC @ 2 Amps Max Hot Swappable Operating Temperature Range 0 ° C - +50 ° C (32 ° F – 122 ° F) .
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 21 5 CUSTOMER SUPPORT Contact Information If you have any questions, please do not hesitate to contact us at: Americas Support MRV (East Coast USA) 295 Foster Street Littleton, MA 01460-2016 Tech Support: (800) 338-5316 Tech Support: (978) 952-4700 E-mail: support@fiberdriver.
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 22 5 GLOSSARY Complete definition of networking term s (jargon) used in this manual, may be found on our ftp site: ftp://ftp.fiberdriver.com/pub/doc/Glossary.pdf 6 ORDERING INFORMATION Please visit us at http://www.
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 23 Place Stamp Here ---------- ---------------- ------------------ ---- ---------- ---------------- ------------------ ---- ---------- ---------------- ------------------ ---- 8928 Fullbright Avenue Chatsworth, California 91311 U .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il MRV Communications EM316T1 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del MRV Communications EM316T1 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso MRV Communications EM316T1 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul MRV Communications EM316T1 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il MRV Communications EM316T1, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del MRV Communications EM316T1.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il MRV Communications EM316T1. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo MRV Communications EM316T1 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.