647 BFC cover 8/18/00 djt M400BFC Balanced Flue (Closed Combustion) Heat-Circulating Fireplace For use in the U.S. / Canada Underwriter ’s Laboratories Report No.
2 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 M400BFC Listed UL127 / ULC-S610 Standard for Factory Built Fireplaces Safety Information ...................................................................................... 3 Specifications and Framing .
3 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Safety Information Please Read This Manual Before Installing and Using Fireplace IMPORT ANT : Read all instructions and warnings carefully before starting installation. Failure to follow these instruc- tions may result in a possible fire hazard and will void the warranty .
4 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 M400BFC Balanced Flue Heat-Circulating Fireplace Fig. 1 M400BFC specifications and framing. 6 " (16mm) 56O " (13mm) 56O ".
5 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 FP554a BFC Fireplace and chase parts identification circulating model 8/21/00 djt T ermination Cap Storm Collar Pan Flashing Draftstop Stando.
6 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 D Rise B G H B Offset C E 6 FT . G H A Hearth Floor Chimney Section CHIMNEY FLUE EXIT Elbow FP269 MBUF 5/16/96 rev . 5/25 TCS8A Support Example 1 Example 2 Example 3 Chimney Requirements - Offset Installations Notes: G + H cannot exceed 20 feet.
7 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Planning Information Preplanning an installation is very important to ensure safety and to save time and money . An installer must predetermine where a fireplace will be set and how the chimney system will be run.
8 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Chimney Supports The chimney system is supported by the fireplace for vertical chimney heights less than 30’ (9 m) above the hearth. Chimney supports are required if the vertical height exceeds 30’ (9 m).
9 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 FPC555a Platform insulation BFC model 8/21/00 djt Hard Flat Surface Insulation Platform FPC555a Fig.
10 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Offset Installation In order to clear an obstruction, it may be necessary to offset chimney from vertical. This is accomplished by using elbows. Use the 30° Offset Elbow table on Page 5 to determine proper offset and parts required.
1 1 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Positioning, Safety Strips, Securing the Fireplace Slide fireplace into position. Lift the fireplace front slightly and slide the metal safety strips under front bottom edge about 1 Zx ” (38 mm), allowing the remainder to extend in front of firebox.
12 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Installing the Chimney System Start by attaching the first chimney section to the collar on top of the fireplace. Install the pipe as pictured in Figure 14. When you get a good lock, you will hear the pipe clearly snap together .
13 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Firestop spacers are not available for , nor are they required on vertical walls. DO NOT put any sealant around the area where the outer pipe slides through the firestop spacer . If you seal this area, it may cause a fire hazard.
14 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 FRONT VIEW SIDE VIEW Air Space Clearances FPC559a BFC AIR SP ACES circulating models 8/21/00 djt Standoff Combustible framing material MUST NOT penetrate AIR SP ACE (shaded areas).
15 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 MA81 rev. 8/5/97 1 Zx " Ref. B C Combustible materials are permitted within a shaded area shown in Figure 21 titled Minimum W all Clearances. * * * MA81 Fig. 20 Combustible mantel clearances.
16 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Side W all Protection Adjacent combustible side walls that are within mini- mum dimensions shown in Figure 24 of the fireplace opening must be protected with MHSC W all Shield Model SP40 or a specifically built wall shield described in Figure 18.
17 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 W ARNING: Hearth extension must be installed in accordance with Figure 23 and must not cover the bottom front opening of the circulating model.
18 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Installing Line for Gas Logs MHSC fireplaces are designed to accept a 1/2” (13 mm) gas line for installation of an approved gas appliance. (MHSC manufactures a wide variety of gas logs for use in MHSC fireplaces.
19 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 647 BFC parts 2008 2/08 djt 1 2 3 5 6 7 8 9 10 1 1 12 13 14 16 15 19 18 17 4 24 20 22 21 25 23 23 26 27 28 29 MHSC reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
20 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 M400BFC Balanced Flue Fireplace (continued) 17. Blower Assembly - FKSX-A 20000620 18. Grate Retainer 2353179 19. Junction Box Assembly 3126161 20. Ceramic Glass Panel (two per fireplace) 30004352 21.
21 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 The following accessories for this appliance are available from your local Monessen distributor . Should you need ad- ditional information beyond what your distributor can furnish, contact: MHSC, 149 Cleveland Drive, Paris, KY 40361, Attn: T echnical Services.
22 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 Chimney Components Component Description Model Number Chimney Support Used to support chimney for each of TCS8A 30’ vertical height and 6.
23 M400BFC Balanced Flue Heat-Circulating Fireplace 87D1505 LIMITED W ARRANTY Factory-Build Fireplace and Components (Except Blowers) What is Covered and For How Long Five-Y ear Coverage: For five yea.
MHSC 149 Cleveland Drive • Paris, Kentucky 40361 www .mhsc.com.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Monessen Hearth M400BFC è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Monessen Hearth M400BFC - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Monessen Hearth M400BFC imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Monessen Hearth M400BFC ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Monessen Hearth M400BFC, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Monessen Hearth M400BFC.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Monessen Hearth M400BFC. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Monessen Hearth M400BFC insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.