743000 BLDV 7 cover 74D3000 5/10 Rev .
74D3000 BLD V7 Se r ies Gas F ireplace .
74D3000 3 BLD V7 Se r ies Gas F ireplace 4. Never install the fireplace • in a recreational vehicle • where curtains, furniture, clothing, or other flam- mable objects are less than 4" from the front, top, or sides of the fireplace • in high traffic areas • in windy or drafty areas 5.
74D3000 4 BLD V7 Se r ies Gas F ireplace 1. Do n ot use this fire pla ce to cook food or burn paper or other objects.
74D3000 5 BLD V7 Se r ies Gas F ireplace • This appliance has been certified for use with either natural or propane gas. See appropriate data plates. • This appliance is not for use with solid fuels.
74D3000 6 BLD V7 Se r ies Gas F ireplace R - Rough Opening Width Rough Opening Height Rough Opening Depth A B C .
74D3000 7 BLD V7 Se r ies Gas F ireplace Read this homeowner manual thoroughly and follow all instructions carefully . Inspect all contents for shipping dama ge and i mmed iate ly inform your deale r i f any da mage is found.
74D3000 8 BLD V7 Se r ies Gas F ireplace Plan for the installation of your appliance.
74D3000 9 BLD V7 Se r ies Gas F ireplace The combustible area above the facing must not protrude more than 3/4" from the facing.
74D3000 10 BLD V7 Se r ies Gas F ireplace The fireplace must be secured to the floor and/or to framing studs as shown in Figure 5. Use two () wood screws or masonry/ concrete screws to secure fireplace to the floor . Use four (4) screws to attach fireplace to framing.
74D3000 1 1 BLD V7 Se r ies Gas F ireplace Consult local building codes before beginning the installation. The installer must make sure to select the proper vent system for installation.
74D3000 1 BLD V7 Se r ies Gas F ireplace V V V V V V V X X X D E B B B C B M B A J K F L VENT TER.
74D3000 13 BLD V7 Se r ies Gas F ireplace FP 23 36 fl ex v ent t op Outside Corner Inside Corner T ermination Clearances T ermination clearances for buildings with combustible and noncombustible exteriors.
74D3000 14 BLD V7 Se r ies Gas F ireplace When using twist lock pipe it is not necessary to use sealant on the joints.
74D3000 15 BLD V7 Se r ies Gas F ireplace .
74D3000 16 BLD V7 Se r ies Gas F ireplace .
74D3000 17 BLD V7 Se r ies Gas F ireplace VO584-100 Vent Opening 2/99 djt 9 B, ” (44 mm) Min.
74D3000 18 BLD V7 Se r ies Gas F ireplace .
74D3000 19 BLD V7 Se r ies Gas F ireplace . Remove soil to a depth of approximately 16” (406 mm) below base of snorkel.
74D3000 0 BLD V7 Se r ies Gas F ireplace 1 2 3 4 1 2 3 4 12” Min. Figure 24 - Maximum Elbow Usage FP1 179 .
74D3000 1 BLD V7 Se r ies Gas F ireplace TWL101a T wist Lock Pipe 2/8/99 djt 3 #5 Sheet Metal Screws per Joint Sealant Storm Collar TWL101a Figure 29 - Roof Flashing 2 ft.
74D3000 BLD V7 Se r ies Gas F ireplace Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace.
74D3000 3 BLD V7 Se r ies Gas F ireplace A listed manual shutoff valve must be installed upstream of the appliance. Union tee and plugged 1/8" NPT pres- sure tapping point should be installed upstream of the appliance.
74D3000 4 BLD V7 Se r ies Gas F ireplace 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal.
74D3000 5 BLD V7 Se r ies Gas F ireplace Figure 33 - Removing Glass Frame 1. Remove access panel by lifting up and out. . Release two clamps (500 model has three clamps) on b ottom of fireplace.
74D3000 6 BLD V7 Se r ies Gas F ireplace A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a junction box at the desired location on the wall.
74D3000 7 BLD V7 Se r ies Gas F ireplace 3. Remove logs. 4. Remove grate from engine by lifting up. 5. Remove hearth brick and wall brick panels. 6. Disconnect the gas line to the valve. 7. Remove screws securing engine base to firebox floor and lift engine up to remove.
74D3000 8 BLD V7 Se r ies Gas F ireplace KT505 install blower Start Position Installed Position KT505 Figure 38 - Blower Installation Position Some older units are not equipped with mounting brackets. V elcro and magnets are used to mount blowers to sidewall and floor .
74D3000 9 BLD V7 Se r ies Gas F ireplace This appliance is equipped with a pilot which must be lit with built-in piezo ignitor while following these instructions exactly .
74D3000 30 BLD V7 Se r ies Gas F ireplace PILOT O F F P I L O T O N FP1935 control knob p.
74D3000 31 BLD V7 Se r ies Gas F ireplace PILOT O F F P I L O T O N O F F P I L O T O N PILO.
74D3000 3 BLD V7 Se r ies Gas F ireplace .
74D3000 33 BLD V7 Se r ies Gas F ireplace 1. This should be done before framing the fireplace.
74D3000 34 BLD V7 Se r ies Gas F ireplace T o Junction Box in Fireplace Optional AC Module { White Black Optional Light White Black { Optional Blower White Black { Optional Aux. Green Plug in Connector Connector Pin T o Control Board Input 300 W att Max.
74D3000 35 BLD V7 Se r ies Gas F ireplace To Junction Box In Fireplace WHITE BLACK WHITE BLACK BLACK WHITE GREEN Connector Pin To Contro l Box { { Optional Light Optional AUX Blower (300w Max) FP2684 .
74D3000 36 BLD V7 Se r ies Gas F ireplace B L A C K B L A C K WHITE GREEN BLACK BLACK WHITE Receptacle Junction Box 120V AC Speed Control FP2685 BL OT SDV blower wiring .
74D3000 37 BLD V7 Se r ies Gas F ireplace This appliance is equipped with an ignition device which automatically lights the pilot.
74D3000 38 BLD V7 Se r ies Gas F ireplace 1. Read the safety information above.
74D3000 39 BLD V7 Se r ies Gas F ireplace .
74D3000 40 BLD V7 Se r ies Gas F ireplace All System configuration/setup is done on the Command Center .
74D3000 41 BLD V7 Se r ies Gas F ireplace .
74D3000 4 BLD V7 Se r ies Gas F ireplace Figure 54 - Rock wool placement 1 . Place rock wool on burner to provide glowing embers.
74D3000 43 BLD V7 Se r ies Gas F ireplace 5. Place the left upper log (#6) at an angle by matching the rectangular notch on the bottom of this log with the rectangular protrusion on the side of the left front log (#5). The split end should point toward the front.
74D3000 44 BLD V7 Se r ies Gas F ireplace Keep the control compartment, logs, and burner areas surrounding the logs clean by vacuuming or brushing at least twice a year .
74D3000 45 BLD V7 Se r ies Gas F ireplace The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person.
74D3000 46 BLD V7 Se r ies Gas F ireplace 1.
74D3000 47 BLD V7 Se r ies Gas F ireplace 4. Frequent pilot outage problem. 5.
74D3000 48 BLD V7 Se r ies Gas F ireplace OPERA TION Install batteries and/or plug in the AC board Flip the master switch (rocker switch) to the ON pos.
74D3000 49 BLD V7 Se r ies Gas F ireplace 4 3 7 6 2 5 743000 BLDV 7 parts 1.
74D3000 50 BLD V7 Se r ies Gas F ireplace .
74D3000 51 BLD V7 Se r ies Gas F ireplace .
74D3000 5 BLD V7 Se r ies Gas F ireplace 743000 BLDV SC par ts 1 2 3 4.
74D3000 53 BLD V7 Se r ies Gas F ireplace 1.
74D3000 54 BLD V7 Se r ies Gas F ireplace 1 6 5 2 3 4 743000 BLDV log parts 1.
74D3000 55 BLD V7 Se r ies Gas F ireplace V ertical V ent T ermination .
74D3000 56 BLD V7 Se r ies Gas F ireplace Horizontal V ent T ermination.
74D3000 57 BLD V7 Se r ies Gas F ireplace.
74D3000 58 BLD V7 Se r ies Gas F ireplace This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts.
74D3000 59 BLD V7 Se r ies Gas F ireplace The fol.
149 Cleveland Drive • Paris, Kentucky 40361 www .mhsc.com Based on CSA P .4.1-09 Based on CSA P .4.1-09 Recher chez dans la broc hure les caractéristique de rendement énergétique de f oyer au gaz Énerguide Selon CSA P .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Monessen Hearth BLDV400N/PV7;N/PSC7 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Monessen Hearth BLDV400N/PV7;N/PSC7 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Monessen Hearth BLDV400N/PV7;N/PSC7 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Monessen Hearth BLDV400N/PV7;N/PSC7 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Monessen Hearth BLDV400N/PV7;N/PSC7, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Monessen Hearth BLDV400N/PV7;N/PSC7.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Monessen Hearth BLDV400N/PV7;N/PSC7. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Monessen Hearth BLDV400N/PV7;N/PSC7 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.