Manuale d’uso / di manutenzione del prodotto PLT200 del fabbricante Monarch
Vai alla pagina of 14
Pocket Laser T ach 200 (PL T200) T achometer / Rate Meter / T ot alizer / Timer MONARCH INSTRUMENT Instruction Manual 15 Columbia Drive Amherst, NH 03031-2334 USA Phone: (603) 883-3390 Fax: (603) 886-3300 E-mail: support@monarchinstrument.com Website: www.
SAFEGUARDS AND PRECAUTIONS W ARNING - This product emits a visible beam of laser light. Avoid exposure to the laser radiation. The use of optical viewing aids (binoculars, for example) may increase the ocular hazard. CAUTION - The laser beam should not be intentionally aimed at people or animals.
T ABLE OF CONTENTS T ABLE OF CONTENTS 1 . 0 OVERVIEW ............................................................................. 1 2 . 0 FEA TURE LOCA TIONS ............................................................ 1 3 .0 LCD DISPLA Y SYMBOLS ...
1 1. 0 OVERVIEW The Pocket Laser T ach 200 is a precision hand-held multifunction T achometer , Ratemeter , T otalizer and Timer . It is programmable to display directly in Revs, Inches, Feet, Y ards, Miles, Centimeters and Meters or function as a stopwatch or interval timer .
2 3.0 LCD DISPLA Y SYMBOLS On T arget Indicator . Blinks on whenever there is an input signal. Will appear to be solid on at higher frequencies. Low Battery icon. Indicates that the batteries are low and need to be replaced. T imes T en icon. Indicates that the value shown is ten times that which is displayed.
3 4.0 PL T200 SPECIFICA TIONS Laser Specifications: Classification: Class 3R (per IEC 60825-1 Ed 1.2 2001-8) Complies with FDA performance standards for laser products except for deviations pursuant to Laser Notice No. 50, dated July 26, 2001. Maximum Laser Output: 3mW Pulse Duration: Continuous Laser W avelength: 650 nm Beam Divergence: < 1.
4 Contact Specifications (continued): Accuracy: Revs: ±0.05% of reading (RPM) or resolution limit (with no slippage) Linear: ± 0.5% of reading or resolution limit (with no slippage) Contact Measurements Ranges: T ACHOMETER: Revolutions per Minute (RPM) 0.
5 Contact Measurements Ranges (continued): RA TES: Wheel Circumference: Y ards per Hour 10cm: 3.281 to 131,233 YPH 12 in: 10.000 to 240,000 YPH Miles per Hour 10 cm: 0.002 to 74.564 MPH 12 in: 0.006 to 136.36 MPH Centimeters per Second 10 cm: 0.084 to 3,333.
Display: 5 x 0.5” (12.7mm) numeric digits plus 5 Alpha-numeric LCD Batteries: 2 “AA” 1.5 V (DC) alkaline included (Note: Batteries are NOT rechargeable.) Battery Life: 30 hours continuous typical with batteries provided External Input: Absolute max: -0.
7 5.0 PREP ARA TION FOR MEASUREMENT 5. 1 Non-Contact Preparation For Internal operation (Red laser) or External operation using optional Remote Optical Sensor (ROS-Red LED). 5 .2 Direct Contact Preparation For External operation ONL Y using optional Remote Contact Assembly (RCA).
8 5 .3 Connecting External Sensors Plug sensor into Input socket Tighten screw securely into flat on shaft. Remote Optical Sensor (ROS-P) Install with pin in shaft fully seated in slot.
9 6.0 T ACHometer Mode 6 .1 T ACHometer Setup 1. Turn Power ON 2. Enter Setup Mode 3. Enter selection of Mode 4. Select T ACH Mode 5. Save and advance 6.
NONE , 1 , 2 or 3 OR Repeat until desired decimal places displayed Unit will remember these settings (including lock on/off) even if turned off and back on. OR Repeat until desired Units displayed DONE , then Units selected 10 7. Select Units 8. Save and advance 9.
11 Measure Recall Max Recall Min If unit Locked on: Power OFF Min Speed Max Speed Automatic after 90 seconds if unit not Locked on OR Press and hold Lock on 6 .2 T ACHometer Operation Resets Max/Min OR 12 1. Turn Power ON 2. Enter Setup Mode 3. Enter selection of Mode 4.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Monarch PLT200 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Monarch PLT200 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Monarch PLT200 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Monarch PLT200 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Monarch PLT200, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Monarch PLT200.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Monarch PLT200. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Monarch PLT200 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.