For A Ethernet Interface Module User’s Manual (Hardware) AJ71E71N-B5T, A1SJ71E71N-B5T AJ71E71N-B2, A1SJ71E71N-B2 Thank you for buying the Mitsubishi general- purpose progr ammable logi c contro ller MELS EC-A Se ries Prior to use, pl ease read both this manual and detailed manual thoroug hly and familiarize yourself with the product.
A- 1 DA NGER CA UTION ! SAFETY PRECAUTIONS ! (Alw ays read before starti ng use) W hen using Mitsubishi eq uipment, thoroug hly read thi s manual and the associated manuals introduced in the manual . Also pay careful attention to safety and handle the module properly .
A- 2 [INSTA LLA TION PRECA UTIONS] CA UTION ! Install so that the tabs at the bottom of the module fit securely into the base unit mounting holes. ( The AnS series module shall be fastened by scr ews in the base uni t at the specified torque.
A- 3 Rev isions The manual number is given on the bottom lef t of the back cover. Print Date Manual Number Revi sion Jan., 2002 IB(NA)- 0800203-A First pr inting This manual confers no industrial property r ights or any rig hts of any other kind, nor does it confer any patent lic enses.
A- 4 CONTENTS 1. Overv iew ................................................................................................................... .......... 1 2. Performance Specifications .................................................................
A- 5 A bout the Manuals The following product are av ailable for this equipment. Refer to the table gi ven below to choose suitable manuals. Related Manual Manual name Manual No.
1 1. Ov erview This manual ex plains how to i nstall the follow ing Ethernet i nterface modules (abbrev iated as E71 hereafter) for A series PLC CPU and how to wir e them with ex ternal dev ices. After unpacking E71, v erify that the follow ing parts ar e contained.
2 2. Performance Specification s The performance specifications of E71 is shown bel ow. See CPU module user’s manual to be used for E71 general speci fications. Specifications Topic 10BASE5 10BASE2 10BASE-T Data tran smission speed 10 Mbps Transmission method Base band Max imum distance between nodes 2500 m (8202.
3 Notes (1) Each item in the transmi ssion specifications gi ves supplementary explanati on. • W hen connected by 10BASE2, 10BASE5 Segment leng th Segment leng th Node Node Node Node Node Transceive.
4 3. Settings and Names o f Each Part A J71E7 1N-B2 RUN RDY BSY SW.ERR. COM.ERR. CPU R/W BUF1 BUF2 BUF3 BUF4 BUF5 BUF6 BUF7 BUF8 TEST TEST ERR. MODE SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 A J71E7 1N-B5 T MODE 0:ONL INE 1:OFFL INE 2:TES T1 3:TES T2 4:TES T3 10BAS E-T EXT .
5 No Desig nation Contents 1) Display LED Refer to (1) 2) Operation mode setting switch Refer to (2) 3) Exchang e condition setting switch Ref e r to (3) 4) 10BASE-T connector Connector for connecting the E71 to the 10BASE-T.
6 Rema rk The order of the display LEDs is show n below. RUN RDY BSY SW.ERR. COM.ERR. CPU R/W BUF1 BUF2 BUF3 BUF4 BUF5 BUF6 BUF7 BUF8 TEST TEST E RR. RUN RDY BSY SW.
7 (3) Communicati ons exchange condi tion setting sw itch setting Set the conditions for data communication w ith other nodes. Communications exchang e condition setting switch Switch Setting desig nation Setting contents Selects the line processi ng when the TCP ULP time out error occurrence.
8 4. Loading a nd Installa tion The following is ex planations of the handling precautions and installation envir onment whic h is common to modules w hen handling E71 from unpacki ng to installati on. For the details of loadi ng and installati on of the module, refer to User’s M anual of CPU module to be used.
9 5. Connection to a Netw ork The following is an ex planation of the connection method of the E71 to the 10 BASE-T, 10BASE5 or the 10BASE2. Point (1) Installati on procedures of the network require sufficient safety measures. For the execution of such operations as ter minal processing of connection cable, trunk line cable etc.
10 5.1 Connecting to t he 10BA SE-T (A J71E71N-B5T, A 1 SJ71E71N-B5T) For A J71E71N-B5T <Connection pr ocedure> 1) Connect the tw isted pair cabl e and the hub.
11 6. External Dime nsions (1) AJ71E71N- B5T A J71E71N-B5T 13.8 ( 0.52 ) 106 ( 4.17 ) 37.5 ( 1.48 ) 250 (9.84) MODE 10BASE-T EXT.PW SW8 SW1 SW2 SW3 SW4 SW5 SW6 SW7 (FG ) EXT.PW OFF ON 10BASE5 ( 1) R1 ( 2) R2 0 8 F 7 E 6 D 5 C 4 B 3 A 2 9 1 BUF1 BUF2 BUF3 BUF4 BUF5 BUF6 BUF7 BUF8 TEST TEST ERR.
12 (2) A1SJ71E71N- B5T A 1SJ71E71N- B5T RUN RDY BSY SW.ERR. COM.ERR . TEST TEST ERR. CPU R/W MODE 0:ON LINE 1:OFFLINE 2:TES T1 3:TES T2 4:TES T3 10BASET 10BASE5 A1SJ 71E7 1N-B 5T BUF1 BUF2 BUF3 BUF4 BUF5 BUF6 BUF7 BUF8 0 8 F 7 E 6 D 5 C 4 B 3 A 2 9 1 ( 1) R1 ( 2) R2 93.
Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi ; machine damage or lost pr ofits caused by faults in the Mitsubi shi products; damage,.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Mitsubishi A1SJ71E71N-B2 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Mitsubishi A1SJ71E71N-B2 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Mitsubishi A1SJ71E71N-B2 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Mitsubishi A1SJ71E71N-B2 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Mitsubishi A1SJ71E71N-B2, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Mitsubishi A1SJ71E71N-B2.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Mitsubishi A1SJ71E71N-B2. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Mitsubishi A1SJ71E71N-B2 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.