Manuale d’uso / di manutenzione del prodotto XMT 456CV del fabbricante Miller Electric
Vai alla pagina of 44
OM-203 034N 2007 − 10 Processes MIG (GMA W) W elding With Optional Equipment: Pulsed MIG (GMAW -P) XMT 456 CC/CV: Multiprocess W elding Description Invision 456P: Invision 456P: XMT 456 CC/CV: R Invision 456P And X M T 4 5 6 C C / C V (400 V olt Models) R File: MIG (GMA W) V isit our website at www.
Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual specification sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .
T ABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
dec_stat_6/05 Declaration of Conformity for European Community (CE) Products . This information is provided for units with CE certification (see rating label on unit). Manufacturer : European Contact: Miller Electric Mg. Co. Mr . Danilo Fedolfi, 1635 W .
OM-203 034 Page 1 SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING som _2007 − 04 7 Protect yourself and others from injury — read and follow these precautions. 1-1. Symbol Usage DANGER! − Indicates a hazardous situation which, if not avoided, will result in death or serious injury .
OM-203 034 Page 2 W elding produces fumes and gases. Breathing these fumes and gases can be hazardous to your health. FUMES AND GASES can be hazardous. D Keep your head out of the fumes. Do not breathe the fumes. D If inside, ventilate the area and/or use local forced ventilation at the arc to remove welding fumes and gases.
OM-203 034 Page 3 D Read and follow instructions on compressed gas cylinders, associated equipment, and Compressed Gas Association (CGA) publication P-1 listed in Safety Standards. 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard.
OM-203 034 Page 4 1-4. California Proposition 65 W arnings W elding or cutting equipment produces fumes or gases which contain chemicals known to the State of California to cause birth defects and, in some cases, cancer. (California Health & Safety Code Section 25249.
OM-203 034 Page 5 SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE A V ANT UTILISA TION fre_som_2007 − 04 7 Se protéger et protéger les autres contre le risque de blessure — lire et respecter ces consignes.
OM-203 034 Page 6 Il reste une TENSION DC NON NÉGLIGEABLE dans les sources de soudage onduleur quand on a coupé l’alimentation. D Arrêter les convertisseurs, débrancher le courant électrique et décharger les condensateurs d’alimentation selon les instructions indiquées dans la partie Entretien avant de toucher les pièces.
OM-203 034 Page 7 LES ACCUMULA TIONS DE GAZ risquent de provoquer des blessures ou même la mort. D Fermer l’alimentation du gaz protecteur en cas de non-utilisation. D V eiller toujours à bien aérer les espaces confi- nés ou se servir d’un respirateur d’adduction d’air homologué.
OM-203 034 Page 8 LES FILS DE SOUDAGE peuvent provoquer des blessures. D Ne pas appuyer sur la gâchette avant d’en avoir reçu l’instruction. D Ne pas diriger le pistolet vers soi, d’autres per- sonnes ou toute pièce mécanique en enga- geant le fil de soudage.
OM-203 034 Page 9 2-5. P ri nc ipa le s no rm es d e sé cu ri té Safety i n W elding, Cutting, and Allied Processes, ANSI Standard Z49.1, de Global Engineering Documents (téléphone : 1-877-413-5184, site Internet : www .
OM-203 034 Page 10.
OM-203 034 Page 1 1 SECTION 3 − DEFINITIONS 3-1. Manufacturer ’ s W arning Label Definitions W arning! Watch Out! There are possible hazards as shown by the symbols. 1 Electric shock from welding electrode or wiring can kill. 1.1 Wear dry insulating gloves.
OM-203 034 Page 12 > 60 s V S-179 190-A V V 1 Warning! W atch Out! There are possible hazards as shown by the symbols. 2 Electric shock from wiring can kill. 3 Disconnect input plug or power before working on machine. 4 Hazardous voltage remains on input capacitors after power is turned off.
OM-203 034 Page 13 3-2. Symbols And Definitions A Amperage Panel Alternating Current (AC) V V oltage Output Circuit Breaker Remote On Of f Gas Tungsten Arc W elding Negative V oltage Input Direct Curr.
OM-203 034 Page 14 3-4. Manufacturer ’ s Rating Labels 217 204-C / 223 527-B . CV Model . CC/CV Model.
OM-203 034 Page 15 SECTION 4 − INST ALLA TION . This manual contains information on CC and CC/CV units. Differences between models are noted throughout this manual.
OM-203 034 Page 16 4-3. V olt-Ampere Curves V olt-ampere curves show mini- mum and maximum voltage and amperage output capabilities of unit. Curves of other settings fall be- tween curves shown. va_curve1 4/95 − SA-181 561 / SA-181 562 CC Modes CV Modes 4-4.
OM-203 034 Page 17 4-5. Selecting A Location loc_2 3/96 - 800 61 1 / 802 260 1 Lifting Forks Use lifting forks to move unit. Extend forks beyond opposite side of unit. 2 Lifting Handles Use handles to lift unit. 3 Hand Cart Use cart or similar device to move unit.
OM-203 034 Page 18 4-7. W eld Output T erminals And Selecting Cable Sizes ! ARC WELDING can cause Electromagnetic Interference. T o reduce possible interference, keep weld cables as short as possible, close together, and down low , such as on the floor.
OM-203 034 Page 19 4-8. Connecting Weld Output Cables 803 778-B ! T urn off power before connecting to weld output terminals. ! Failure to properly connect weld cables may cause excessive heat an d start a fire, or damage your ma- chine.
OM-203 034 Page 20 4-10. 1 15 V olts AC Duplex Receptacle Ref. 801 524-A 1 1 15 V 7 A AC Receptacle Power is shared between duplex receptacle and Remote 14 recep- tacle (see Section 4-9). 2 Circuit Breaker CB1 3 Circuit Breaker CB2 CB 1 protects 1 15 volts ac portion of duplex receptacle and Remote 14 receptacle from overload.
OM-203 034 Page 21 4-12. Connecting Input Power ssb2.4* 1/94 − 801 523-B / 801 946 T ools Needed: 5/16 in Input Filter Board L1 =GND/PE ! T urn Off welding power source, and check voltage on input capacitors according to Section 6-3 before pro- ceeding.
OM-203 034 Page 22 SECTION 5 − OPERA TION 5-1. Front Panel Controls For CV Only Models 1 Power On/Off Switch . The fan motor is thermostatically controlled and only runs when cooling is needed.
OM-203 034 Page 23 5-3. Meter Functions For CV Only Models . The meters display the actual weld output values for approximately three seconds after the arc is broken. Mode Meter Reading At Idle Meter Reading While W elding MIG Preset V olts Blank VA 24.
OM-203 034 Page 24 5-5. Meter Functions For CC/CV Models . The meters display the actual weld output values for approximately three seconds after the arc is broken. Mode Meter Reading At Idle Panel Control (GT AW) Actual V olts (OCV) Preset Amps VA 80.
OM-203 034 Page 25 5-6. Mode Switch Settings For CC/CV Models . Th e SMA W modes provide the Adaptive Hot Start ™ feature, which automatically increases the output amperage at the start of a weld should the start require it. This eliminates electrode sticking at arc start.
OM-203 034 Page 26 5-7. Lift-Arc TIG Procedure For CC/CV Models With Mode switch in the Lift-Arc TIG position, start an arc as follows: 1 TIG Electrode 2 W orkpiece T ouch tungsten electrode to work- piece at weld start point, hold electrode to workpiece for 1-2 seconds , and slowly lift electrode.
OM-203 034 Page 27 SECTION 6 − MAINTENANCE & TROUBLESHOOTING 6-1. Routine Maintenance ! Disconnect power before maintaining. . Maintain more often during severe conditions.
OM-203 034 Page 28 6-3. Removing Case and Measuring Input Capacitor V oltage Turn Of f welding power source, a nd disconnect input power . 1 Outside Handle Screws T o loosen top, remove two outside handle screws from both handles and all side bolts.
OM-203 034 Page 29 6-4. V oltmeter/Ammeter Help Displays . Al l directions are in reference to th e front of the unit. All circuitry referred to is located inside the unit. 1 Help 0 Display Indicates a shorted thermistor R T2 on the left side of the unit.
OM-203 034 Page 30 6-5. T roubleshooting T rouble Remedy No weld output; unit completely inop- erative. Place line disconnect switch in On position (see Section 4-12 ). Check and replace line fuse(s), if necessary , or reset circuit breaker (see Section 4-12 ).
OM-203 034 Page 31 Notes.
OM-203 034 Page 32 SECTION 7 − ELECTRICAL DIAGRAM Figure 7-1. Circuit Diagram For CV Only Welding Power Source.
OM-203 034 Page 33 203 505-A.
OM-203 034 Page 34 Figure 7-2. Circuit Diagram For CC/CV Welding Power Source.
OM-203 034 Page 35 204 950 − B.
OM-203 034 Page 36 SECTION 8 − P ARTS LIST . Hardware is common and not available unless listed. 802 261-E 68 67 57 56 55 52 10 61 60 47 43 36 38 37 36 35 34 30 8 7 6 5 4 66 3 PC2 PC1 4 65 64 63 62 59 58 54 53 51 46 50 49 48 46 45 44 4 42 41 40 39 33 32 31 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 9 2 1 Figure 8-1.
OM-203 034 Page 37 Description Part No. Dia. Mkgs. Item No. Figure 8-1. Complete Assembly Quantity 1 187 234 Cover , T op 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-203 034 Page 38 Description Part No. Dia. Mkgs. Item No. Figure 8-1. Complete Assembly (Continued) Quantity 48 180 732 Boot, Neg Output Stud 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 2007 − 01 Y our distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours.
PRINTED IN USA © 2007 Miller Electric Mfg. Co. 2007 − 01 Miller Elect ric Mfg. Co. An Illinois T ool W orks Compa ny 1635 West S pencer S treet Applet on, WI 5 4914 US A International He adquarters.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Miller Electric XMT 456CV è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Miller Electric XMT 456CV - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Miller Electric XMT 456CV imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Miller Electric XMT 456CV ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Miller Electric XMT 456CV, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Miller Electric XMT 456CV.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Miller Electric XMT 456CV. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Miller Electric XMT 456CV insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.