Migmatic 221/253 Processes Description MIG (GMA W) W elding Flux Cored (FCA W ) W elding Arc Welding Power Source Wire Feeder OM-229 038D 2007−04 Effective with serial number 226 214 R.
Thank you and congratulations on choosing Miller . Now you can get the job done and get it done right. W e know you don’ t have time to do it any other way . That’ s why when Niels Miller first started building arc welders in 1929, he made sure his products offered long-lasting value and superior quality .
T ABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
dec_stat_Milan_6/05 Declaration of Conformity for European Community (CE) Products This information is provided for units with CE certification (see rating label on unit).
OM-229 038 Page 1 SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING som _3/05 Y W arning: Protect yourself and others from injury — read and follow these precautions. 1-1. Symbol Usage Means W arning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols.
OM-229 038 Page 2 Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin. Sparks fly off from the weld.
OM-229 038 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring − be sure power supply system is properly sized, rated, and protected to handle this unit.
OM-229 038 Page 4 1-5. Principal Safety Standards Safety i n W elding, Cutting, and Allied Processes, ANSI Standard Z49.1, from Global Engineering Documents (phone: 1-877-413-5184, website: www .
OM-229 038 Page 5 SECTION 2 − DEFINITIONS W arning! W atch Out! There are possible hazards as shown by the symbols. 1 Electric shock can kill. 1.1 W ear dry insulating gloves. Do not touch electrode with bare hand. Do not wear wet or damaged gloves.
OM-229 038 Page 6 W arning! Watch Out! There are possible hazards as shown by the symbols. Electric shock from wiring can kill. Disconnect input plug or power before working on machine.
OM-229 038 Page 7 1 Warning! W atch Out! There are possible hazards as shown by the symbols. 2 Electrical shock from wiring can kill. 3 Read Owner ’ s Manual before working on this machine 4 W ear approved safety glasses 5 Electrode Positive (Straight Polarity) 6 Electrode Negative (reverse Poalrity) 1 2 4 3 5 6 2-1.
OM-229 038 Page 8 SECTION 3 − INST ALLA TION 3-1. Specifications Rated Output Max. Rated Input Amperage at Rated Output Rated Output Max. Open Circuit Rated Input Amperage at Rated Output Dimension W eight Model 100% 60% 20% Open Circuit V oltage 220/230 V AC 50Hz Dimension (mm) W eight (kg) 221 90 A 18.
OM-229 038 Page 9 3-3. V olt-Ampere Curves Th e volt-ampere curves show the normal minimum and maximum voltage and amperage output capabilities of the welding power source. Curves of other settings fall between the curves shown. Model 253 MIN MAX Model 221 3-4.
OM-229 038 Page 10 3-5. Installing Wire Spool and Adjusting Hub T ension 072573-B When a slight force is needed to turn spool, tension is set. 24 mm (15/16 in) Use compression spring with 200 mm (8 in) spools.
OM-229 038 Page 1 1 3-7. Electrical Service Guide Migmatic Model 221 253 Input V oltage 220/230 230 400 Input Amperes at Rated Output 26 23 13 Max Recommended Standard Fuse or Circuit Breaker Rating i.
OM-229 038 Page 12 B. 3-Phase 803 766-A Y Installation must meet all National an d Local Codes − have only quali- fied persons make this installation.
OM-229 038 Page 13 3-9. Installing Drive Rolls and Wire Guide 1 Securing Screw 2 Inlet Wire Guide Loosen screw . Slide tip as close to drive rolls as possible without touching. Tigh ten screw . 3 Anti-W ear Guide Install guide as shown. 4 Drive Roll The drive roll consists of two dif fer- ent sized grooves.
OM-229 038 Page 14 3-10. Threading W elding Wire and Adjusting Pressure Roll T ension 1 Wire Spool 2 Welding Wire 3 Inlet Wire Guide 4 Pressure Adjustment Knob 5 Drive Roll 6 Outlet Wire Guide 7 Gun Conduit Cable Lay gun cable out straight. 4 7 5 6 2 1 T ools Needed: 150 mm .
OM-229 038 Page 15 1 Consumable Storage Compartment Press latch down to release and open door . Provides storage space for gas nozzles, contact tips, gas dif fusers.
OM-229 038 Page 16 SECTION 4 − OPERA TION 4-1. Controls for Migmatic 221/253 1 Power Switch 2 V oltage Control T urn control clockwise to increase voltage. 3 High T emperature Shutdown Light (Orange LED) 4 Digital Display* V olts/Amps/Wire Feed Speed with last value hold function.
OM-229 038 Page 17 SECTION 5 − MAINTENANCE &TROUBLESHOOTING 5-1. Routine Maintenance Y Disconnect power before maintaining. . Maintain more often during severe conditions. 3 Months Replace unreadable labels Repair or replace cracked weld cable Clean and tighten weld terminals 6 Months Blow out or vacuum inside.
OM-229 038 Page 18 5-4. T roubleshooting T rouble Remedy No weld output; wire does not feed. Be sure line disconnect switch is On (see Section 3-8). Replace building line fuse or reset circuit breaker if open. Reset circuit breaker CB1 (see Section 5-2).
OM-229 038 Page 19 Notes.
OM-229 038 Page 20 SECTION 6 − ELECTRICAL DIAGRAMS September 21, 2006 W ARNING Electric Shock Hazard S Do not touch live electrical parts. S Disconnect input power or stop engine before servicing. S Do not operate with covers removed. S Have only qualified persons install, use, or service this unit.
OM-229 038 Page 21 September 21, 2006 W ARNING Electric Shock Hazard S Do not touch live electrical parts. S Disconnect input power or stop engine before servicing. S Do not operate with covers removed. S Have only qualified persons install, use, or service this unit.
OM-229 038 Page 22 SECTION 7 − P ARTS LIST Figure 7-1. W rapper Assembly , All Models.
OM-229 038 Page 23 Description Part No. Item No. Figure 7-1. W rapper Assembly , All Models Quanti ty 1 156034005 Catch, side panel 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 156122062 Side Panel, hinged 1 .
OM-229 038 Page 24 Figure 7-2. Main Assembly for Migmatic 221.
OM-229 038 Page 25 Description Part No. Dia. Mkgs. Item No. Figure 7-2. Main Assembly for Migmatic 221 Quanti ty 1 956142538 Label 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-229 038 Page 26 Figure 7-3. Main Assembly for Migmatic 253.
OM-229 038 Page 27 Description Part No. Dia. Mkgs. Item No. Figure 7-3. Main Assembly for Migmatic 253 Quantity 230V 400V 1 956142538 Label 1 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-229 038 Page 28 T able 7-1. Drive Roll And Wire Guide Kits (2 Roll Models) Base selection of drive rolls upon the following recommended usages: 1. V -Grooved rolls for hard wire. 2. U-Grooved rolls for soft and soft shelled cored wires. 3. U-Cogged rolls for extremely soft shelled wires (usually hard surfacing types).
Notes.
Notes.
Effective January 1, 2007 This limited warranty supersedes all previous Miller warranties and is exclusive with no other guarantees or warranties expressed or implied. LIMITED W ARRANTY − Subject to the terms and conditions below , ITW W elding Products Italy S.
PRINTED IN USA © 2007 Miller Electric Mfg. Co. 1/07 I TW W elding Products Italy S.r . l. Via Privata Iseo, 6/E 20098 San Giuliano Milanese, Italy Phone: 39 (0) 2982901 Fax: 39 (0) 298290-203 email: miller@itw−welding.it Model Name Serial/Style Number Purchase Date (Date which equipment was delivered to original customer.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Miller Electric OM-229 038D è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Miller Electric OM-229 038D - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Miller Electric OM-229 038D imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Miller Electric OM-229 038D ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Miller Electric OM-229 038D, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Miller Electric OM-229 038D.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Miller Electric OM-229 038D. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Miller Electric OM-229 038D insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.