Manuale d’uso / di manutenzione del prodotto OM-220 390F del fabbricante Miller Electric
Vai alla pagina of 48
Axcess W ire Feeder Processes Description Wire Feeder OM-220 390F 2006 − 08 MIG (GMA W) W elding Pulsed MIG (GMAW -P) Flux Cored (FCA W ) W elding ™ File: Advanced Manufacturing Systems V isit our website at www.
Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual specification sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .
T ABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
dec_wire_2/04 Declaration of Conformity for European Community (CE) Products This information is provided for units with CE certification (see rating label on unit). Note Manufacturer : European Contact: Miller Electric Mg. Co. Mr . Danilo Fedolfi, 1635 W .
OM-220 390 Page 1 SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING som _3/05 Y W arning: Protect yourself and others from injury — read and follow these precautions. 1-1. Symbol Usage Means W arning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols.
OM-220 390 Page 2 Arc rays from the w elding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin.
OM-220 390 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring − be sure power supply system is properly sized, rated, and protected to handle this unit.
OM-220 390 Page 4 1-5. Principal Safety Standards Safety i n W elding, Cutting, and Allied Processes, ANSI Standard Z49.1, from Global Engineering Documents (phone: 1-877-413-5184, website: www .
OM-220 390 Page 5 SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE A V ANT UTILISA TION som _3/05 Y A vertissement : se protéger et protéger les autres contre le risque de blessure — lire et respecter ces consignes.
OM-220 390 Page 6 Le rayonnement de l’arc du procédé de soudage génère des rayons visibles et invisibles intenses (ultraviolets et infrarouges) susceptibles de provo- quer des brûlures dans les yeux et sur la peau. Des étincelles sont projetées pendant le soudage.
OM-220 390 Page 7 2-3 . Da ngers s upplé mentai res en r ela tion avec l’insta llation, le fonctionneme nt et l a maintenanc e Risque D’INCENDIE OU D’EXPLO- SION. D Ne pas placer l’appareil sur , au-dessus ou à proximité de surfaces inflammables.
OM-220 390 Page 8 2-5. Princi pales normes de sécur ité Safety in W elding, Cutting, and Allied Processes, ANSI Standard Z49.1, de Global Engineering Documents (téléphone : 1-877-413-5184, site In- ternet : www .
OM-220 390 Page 9 SECTION 3 − DEFINITIONS 3-1. W arning Label Definitions 1 1.1 1.2 1.3 3 3.1 3.2 3.3 4 4.1 + 2 2.1 2.2 + + 56 + 2.3 S-178 936 W arning! Watch Out! There are possible hazards as shown by the symbols.
OM-220 390 Page 10 3-2. Manufacturer ’ s Rating Label For CE Products 225 622-A For label location see Section 5-3. 3-3. Symbols And Definitions Some symbols are found only on CE products.
OM-220 390 Page 1 1 SECTION 4 − INTRODUCTION 4-1. Specifications T ype of Input Power W elding Power Source T ype Wire Feed Speed Range Wire Diameter Range W elding Circuit Rating Overall Dimensions W eight 40 V olts DC 10 Amperes Axcess Series Standard: 40 T o 1400 ipm (1.
OM-220 390 Page 12 Ref. 801 915 / Ref. 803 501-B 1 Welding Power Source 2 Wire Feeder 3 Gas Cylinder 4 Gas Hose 5 Network Feeder Cable 6 Negative ( − ) Weld Cable 7 W orkpiece 8 V oltage Sensing Lead Recommended for Accu-pulse a nd RMD (optional). .
OM-220 390 Page 13 5-3. Rear Panel Connections And Rotating Drive Assembly 802 825-A / 803 503-B 3 4 1 9-Pin Network Receptacle 2 Shielding Gas V alve Fitting Requires fitting with 5/8-18 right- hand threads.
OM-220 390 Page 14 5-4. 9-Pin Network Receptacle Information 9 Pin Pin Information A Capacitor C1 to ground B Shield G F C V olt sense H G E F D Can low I H D E E Can high A B I C D F +24 volts dc common B C G + 24 volts dc H Motor voltage +40 volts dc common I Motor voltage +40 volts dc 5-5.
OM-220 390 Page 15 5-6. Installing And Threading W elding Wire Ref. 156 929-A / Ref. 150 922 / Ref. 156 930 / 802 954 / S-0627-A T ools Needed: . Be sure that outlet cable has proper size liner for the welding wire size. When installing gun, position liner extending from outlet wire guide as close a s possible to drive rolls without touching.
OM-220 390 Page 16 5-7. Feeder Display At Power Up 1 Upper Display 2 Lower Display 2 1 Power Source Upper Display Lower Display Axcess Axcs 300/450/675 10 44 V oltage Range Net W ait DTEC OFF Process Setup Adj ust F eeder Setup V t A 219 71 1-A 5-8.
OM-220 390 Page 17 SECTION 6 − OPERA TION 6-1. Operational T erms The following is a list of terms and their definitions as they apply to the interface unit in the wire feeder: General T erms: Arc Adjust T erm used to represent arc length adjustments in pulse programs.
OM-220 390 Page 18 General T erms: Sequence Selecting Sequence will allow setting of preflow , start, crater , and postflow times and parameters. Preflow Setting a time value for gas flow prior to arc start.
OM-220 390 Page 19 6-3. Front Panel Sections See Section 6-5 See Section 6-6 See Section 6-9 See Section 6-8 See Section 6-7 See Section 6-4 Process S etup Adjust Feeder Setup V t A 219 71.
OM-220 390 Page 20 6-4. Program Push Button 1 3 2 1 Program Display The number of the active program is displayed. 2 Program Push Button 3 Program Push Button LED The LED lights to indicate that programs can be changed using the Adjust knob. Momentarily p ress butt on to illuminate LED.
OM-220 390 Page 21 6-6. Lower Display 1 Lower Display The lower display shows WFS (wire feed speed), AMPS (amperage), ARC CTL (arc control), or Time. The feeder displays only preset wire speed at idle (not welding). While welding, the average amperage is displayed.
OM-220 390 Page 22 6-7. Feeder Set Up Push Button 1 Feeder Set Up Push Button LED 2 Feeder Set Up Push Button • Press button to choose Sequence. Feeder Set Up push-button LED will illuminate. 3 Sequence LED • When the Feeder Set Up button is pressed once, the Sequence LED will illuminate and the upper display will show sequence options.
OM-220 390 Page 23 6-9. Process Set Up Push Button • Press the Process Set Up push button the first time will illuminate the button LED and the Process LED. The upper and lower displays will be used for Accu-pulse and only the lower display for MIG, Pulse and RM D (optional) to show the current process installed in this program.
OM-220 390 Page 24 6-10. Jog/Purge The Jog/Purge switch provides the following functions: • Pressing left side of the Jog/Purge switch allows the operator to feed wire without energizing the weld power or gas valve circuit. The wire will feed at a 50 ipm rate for 3 seconds, then the rate ramps up to 700 ipm until the Jog switch is released.
OM-220 390 Page 25 6-1 1. Reset Mode 198 993 / 803 504-B . Reset mode is not active when Program Lock is enabled. Th e reset mode allows the operator to reload factory program settings for all eight active programs in the unit. . System configuration data will be lost during the Reset operation.
OM-220 390 Page 26 SECTION 7 − SETTING SEQUENCE P ARAMETERS 7-1. Sequence Parameters In A Program . For more information on Sequence mode, see Feeder Set Up Push Button in Section 6-7 . We ld Time can only be set by using an o ptional PD A w ith File Management/WaveWriter soft ware.
OM-220 390 Page 27 SECTION 8 − MAINTENANCE 8-1. Routine Maintenance Y Disconnect power before maintaining. . Maintain more often during severe conditions.
OM-220 390 Page 28 8-2. Diagnostics ERR T ACH • The tach error occurs 2 seconds after the loss of tachometer feedback. The motor speed is re gu la ted through the monitoring of voltage and current. Press Jog/Purge button to clear error . ERR MOTR • The motor error indicates that the motor has been drawing too much current for too long.
OM-220 390 Page 29 8-2. Diagnostics (Continued) WELD W AIT • The weld wait erro r indicates unit was not ready for a weld sequence. Press Jog/ Purge button to clear error . MOTR COM • The motor communication erro r indi- cates motor board lost data communica- tions.
OM-220 390 Page 30 8-3. T roubleshooting Y Disconnect power before troubleshooting T rouble Remedy Wire feeds, shielding gas flows, but electrode wire is not energized. Check and secure weld cable connections (see Section 5-2). Electrode wire feeding stops or feeds erratically during welding Check gun trigger connection.
OM-220 390 Page 31 Notes.
OM-220 390 Page 32 SECTION 9 − ELECTRICAL DIAGRAM Figure 9-1. Circuit Diagram.
OM-220 390 Page 33 21 1 005-E.
OM-220 390 Page 34 SECTION 10 − P ARTS LIST 803 506-C . Hardware is common and not available unless listed. 12 18 20 2 1 3 16 17 7 15 8 11 9 10 6 19 14 11 10 13 5 22 4 − Fi g 10-3 21 − Fig 10-2 Figure 10-1.
OM-220 390 Page 35 Description Part No. Item No. Figure 10-1. Main Assembly Quantity 1 159 647 INSULA TOR, motor clamp 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 159 646 CLAMP , motor base 1 .
OM-220 390 Page 36 803 507-D . Hardware is common and not available unless listed. 2 3 4 5 6 7 9 10 11 8 12 13 14 16 17 16 19 20 21 22 23 24 25 1 15 Figure 10-2. Control Box Description Part No. Dia. Mkgs. Item No. Figure 10-2. Control Box (Fig 10-1 Item 21) Quantity 1 178 936 LABEL, warning general precautionary wordless CE WF 1 .
OM-220 390 Page 37 Description Part No. Dia. Mkgs. Item No. Figure 10-2 . Control Box (Fig 10-1 Item 21) (Continued) Quantity 22 21 1 073 NAMEPLA TE, lower 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-220 390 Page 38 See T able 10-1 For Drive Roll & Wire Guide Kits . Hardware is common and not available unless listed. 802 950-B 9 29 28 35 30 31 32 27 34 26 33 23 22 25 24 21 1 4 3 2 5 6 8 7 4 5 1 2 3 6 16 15 20 10 15 13 18 11 12 14 19 18 17 Figure 10-3.
OM-220 390 Page 39 Description Part No. Dia. Mkgs. Item No. Figure 10-3. Drive Assembly , Wire (Fig 10-1 Item 4) (continued) Quantity 24 134 834 HOSE, SAE .187 ID x .410 OD (order by ft) 2ft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Notes.
Notes.
Notes.
Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 2006 − 01 Y our distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours.
PRINTED IN USA © 2006 Miller Electric Mfg. Co. 2006 − 01 Miller Elect ric Mfg. Co. An Illinois T ool W or ks Compa ny 1635 West S pencer S treet Applet on, WI 5 4914 US A International He adquarter.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Miller Electric OM-220 390F è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Miller Electric OM-220 390F - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Miller Electric OM-220 390F imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Miller Electric OM-220 390F ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Miller Electric OM-220 390F, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Miller Electric OM-220 390F.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Miller Electric OM-220 390F. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Miller Electric OM-220 390F insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.