Pro cesses Descrip ti on Multiprocess W elding Arc Welding Power Source OM -229 409E 2007 − 11 EXTREME 360 CC/CV Auto-Line.
.
T ABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
OM-229 409 Page 1 SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING som _2007 − 04 7 Protect yourself and others from injury — read and follow these precautions. 1-1. Symbol Usage DANGER! − Indicates a hazardous situation which, if not avoided, will result in death or serious injury .
OM-229 409 Page 2 W elding produces fumes and gases. Breathing these fumes and gases can be hazardous to your health. FUMES AND GASES can be hazardous. D Keep your head out of the fumes. Do not breathe the fumes. D If inside, ventilate the area and/or use local forced ventilation at the arc to remove welding fumes and gases.
OM-229 409 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring − be sure power supply system is properly sized, rated, and protected to handle this unit.
OM-229 409 Page 4 1-4. California Proposition 65 W arnings W elding or cutting equipment produces fumes or gases which contain chemicals known to the State of California to cause birth defects and, in some cases, cancer . (California Health & Safety Code Section 25249.
OM-229 409 Page 5 SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE A V ANT UTILISA TION fre_som_2007 − 04 7 Se protéger et protéger les autres contre le risque de blessure — lire et respecter ces consignes.
OM-229 409 Page 6 Il reste une TENSION DC NON NÉGLIGEABLE dans les sources de soudage onduleur quand on a coupé l’alimentation. D Arrêter les convertisseurs, débrancher le courant électrique et décharger les condensateurs d’alimentation selon les instructions indiquées dans la partie Entretien avant de toucher les pièces.
OM-229 409 Page 7 LES ACCUMULA TIONS DE GAZ risquent de provoquer des blessures ou même la mort. D Fermer l’alimentation du gaz protecteur en cas de non-utilisation. D V eiller toujours à bien aérer les espaces confi- nés ou se servir d’un respirateur d’adduction d’air homologué.
OM-229 409 Page 8 LES FILS DE SOUDAGE peuvent provoquer des blessures. D Ne pas appuyer sur la gâchette avant d’en avoir reçu l’instruction. D Ne pas diriger le pistolet vers soi, d’autres per- sonnes ou toute pièce mécanique en enga- geant le fil de soudage.
OM-229 409 Page 9 2-5. P r in ci pa le s no r m es d e sé cu r it é Safety i n W elding, Cutting, and Allied Processes, ANSI Standard Z49.1, de Global Engineering Documents (téléphone : 1-877-413-5184, site Internet : www .
OM-229 409 Page 10.
OM-229 409 Page 1 1 SECTION 3 − INTRODUCTION 3-1. Specifications Input V oltage Amperage Range in Max. Open- Circuit RMS Amps Input at Rated Load Output, 60 Hz 3-Phase at NEMA Load V oltages and Cla.
OM-229 409 Page 12 6 Minutes W elding 4 Minutes Resting 3-3. Duty Cycle And Overheating Duty Cycle is percentage of 10 min- utes that unit can weld at rated load without overheating. If unit overheats, output stops, a Help message is displayed and cooling fan runs.
OM-229 409 Page 13 SECTION 4 − INSTALLATION 4-1. Dimensions And Weight Hole Layout Dimensions 24 in (610 A E A 1 1-3/4 in (298 mm) (610 mm) G F B 1-1 1/16 in (42 mm) 17 in (432 mm) C 15-3/4 in (400 mm) D C D 19-3/32 in (485 mm) C E 8-1 1/16 in (221 mm) 12-1/2 in (318 mm) F 1-17/32 in (39 mm) 804 801-A B G 1/4-20 UNC -2B thread W eight 80 lb (36.
OM-229 409 Page 14 4-3. Connecting 1-Phase Input Power 804 531-A ! Installation must meet all Na- tional and Local Codes − have only qualified persons make this installation. ! Disconnect and lockout/tag- out input power before con- necting input conductors from unit.
OM-229 409 Page 15 4-4. Connecting 3-Phase Input Power 804 531-A ! Installation must meet all National an d Local Codes − have only quali- fied persons make this installation. ! Disconnect and lockout/tagout in- put power before connecting input conductors from unit.
OM-229 409 Page 16 4-5. Electrical Service Guide NOTICE − INCORRECT INPUT POWER can damage this welding power source. Phase to ground voltage shall not exceed +10% of rated input voltage. NOTICE − Actual input voltage should not be 10% less than minimum and/or 10% more than maximum input voltages listed in table.
OM-229 409 Page 17 4-6. W eld Output Receptacles And Selecting Cable Sizes ! ARC WELDING can cause Electromagnetic Interference. T o reduce possible interference, keep weld cables as short as possible, close together, and down low , such as on the floor .
OM-229 409 Page 18 4-7. Remote 14 Receptacle Information Socket* Socket Information 24 VOL TS AC A 24 volts ac. Protected by circuit breaker CB2. AJ B K I 24 VOL TS AC B Contact closure to A completes 24 volts ac contactor control circuit. B K I C L NH 1 15 VOL TS AC I 1 15 volts ac.
OM-229 409 Page 19 ‘ 4-9. Optional Gas V alve Operation And Shielding Gas Connection Ref. 803 705-A / Ref. 803 691-C Obtain gas cylinder and chain to running gear , wall, or other station- ary support so cylinder cannot fall and break of f valve. 1 Cylinder 2 Regulator/Flowmeter Install so face is vertical.
OM-229 409 Page 20 SECTION 5 − OPERATION V/A ADJUST ARC CONTROL ARC CONTROL REMOTE ELECTRODE HOT 5-1. Front Panel Controls 1 Power Switch . The fan motor is thermostatically controlled and only runs when cooling is needed.
OM-229 409 Page 21 5-2. Meter Functions . The meters display the actual weld output values for approximately three seconds after the arc is broken. Mode Meter Reading At Idle Meter Reading While W elding Scratch Start TIG VA Actual V olts (OCV) Preset Amps 71.
OM-229 409 Page 22 5-4. Lift-Arc TIG Procedure With Process Switch in the Lift-Arc TI G position, start an arc as follows: 1 TIG Electrode 2 W orkpiece T ouch tungsten electrode to work- piece at weld start point, hold electrode to workpiece for 1-2 seconds , and slowly lift electrode.
OM-229 409 Page 23 SECTION 6 − MAINTENANCE & TROUBLESHOOTING 6-1. Routine Maintenance . Maintain more often during severe conditions. ! Disconnect power before maintaining.
OM-229 409 Page 24 6-3. V oltmeter/Ammeter Help Displays . All directions are in reference to the front of the unit. All circuitry referred to is lo- cated inside the unit. 1 Help 1 Display Indicates a malfunction in the primary power circuit. If this display is shown, contact a Fac- tory Authorized Service Agent.
OM-229 409 Page 25 Notes Over 80,000 trained since 1930! 400 T rade Square East, T roy , Ohio 45373 1-800-332-9448 www.weldin g .or g Star t Y our Professional W eldin g Career Now!.
OM-229 409 Page 26 SECTION 7 − ELECTRICAL DIAGRAM Figure 7-1. Circuit Diagram.
OM-229 409 Page 27 21 1 328-F.
OM-229 409 Page 28 SECTION 8 − P ARTS LIST Ref. 803 690-H 1 2 3 4 5 6 8 9 10 12 13 15 16 17 18 19 20 21 22 23 24 25 26 28 29 30 31 32 34 35 36 37 38 39 42 43 45 47 46 48 49 50 51 52 53 54 55 56 57 58 59 60 61 63 64 66 68 67 69 70 71 72 73 11 44 65 74 41 76 75 49 62 62 MOD 1 MOD 2 40 17 14 77 Figure 8-1.
OM-229 409 Page 29 Description Part No. Dia. Mkgs. Item No. Figure 8-1. Parts Assembly Quantity 1 229 541 Wrapper (Includes Insulators and Safety Labels) 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175 256 Insulator , Side Rh (Not Shown) 1 .
OM-229 409 Page 30 Description Part No. Dia. Mkgs. Item No. Figure 8-1. Parts Assembly (Continued) Quantity 37 234 126 Nut, Conduit 1.000 Npt Knurled 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-229 409 Page 31 Description Part No. Dia. Mkgs. Item No. Figure 8-1. Parts Assembly (Continued) Quantity 70 174 992 Knob, Pointer .840 Dia X .250 Id W/Spring Clip − .21 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 212 949 Label, Process 1 .
Notes Over 80,000 trained since 1930! 400 T rade Square East, T roy , Ohio 45373 1-800-332-9448 www.weldin g .or g Star t Y our Professional W eldin g Career Now!.
Notes SOCKET/WRENCH SELECTION T ABLE (U.S. ST ANDARD) SOCKET/WRENCH SELECTION T ABLE (METRIC) Specifications Socket or Wrench Size Specifications Socket or Wrench Size Bolt Diameter Decimal Equivalent Bolt Nut Bolt Diameter U.S. Decimal Equivalent Bolt Nut 1/4 in .
Notes 229895 MA TERIAL THICKNESS GAUGE.
Effective January 1, 2007 (Equipment with a serial number preface of “LH” or newer) This limited warranty supersedes all previous manufacturers warranties and is exclusive with no other guarantees or warranties expressed or implied.
PRINTED IN USA 1/07 Model Name Serial/Style Number Purchase Date (Date which equipment was delivered to original customer.) Distributor Address City State Zip Please complete and retain with your personal records.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Miller Electric EXTREME 360 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Miller Electric EXTREME 360 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Miller Electric EXTREME 360 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Miller Electric EXTREME 360 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Miller Electric EXTREME 360, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Miller Electric EXTREME 360.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Miller Electric EXTREME 360. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Miller Electric EXTREME 360 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.