Manuale d’uso / di manutenzione del prodotto 625 del fabbricante Miller Electric
Vai alla pagina of 48
PowCon Arc Stud 625 W elding System R Pro cess Descrip ti on Arc W elding Power Source OM -216 244J 2007 − 03 Stud (SW) W elding ™ File: STUD WELDING (SW) V isit our website at www.
Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual specification sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .
T ABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
OM-216 244 Page 1 SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING som _3/05 Y W arning: Protect yourself and others from injury — read and follow these precautions. 1-1. Symbol Usage Means W arning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols.
OM-216 244 Page 2 Arc rays from the w elding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin.
OM-216 244 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring − be sure power supply system is properly sized, rated, and protected to handle this unit.
OM-216 244 Page 4 1-5. Principal Safety Standards Safety i n W elding, Cutting, and Allied Processes, ANSI Standard Z49.1, from Global Engineering Documents (phone: 1-877-413-5184, website: www .
OM-216 244 Pag e 5 SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE A V ANT UTILISA TION som _3/05 Y A vertissement : se protéger et protéger les autres contre le risque de blessure — lire et respecter ces consignes.
OM-216 244 Page 6 Le rayonnement de l’arc du procédé de soudage génère des rayons visibles et invisibles intenses (ultraviolets et infrarouges) susceptibles de provo- quer des brûlures dans les yeux et sur la peau. Des étincelles sont projetées pendant le soudage.
OM-216 244 Pag e 7 2-3 . Da ngers supplémenta ires en r e la tion avec l’insta lla tion, le f onc tionnem ent et l a maintenanc e Risque D’INCENDIE OU D’EXPLO- SION. D Ne pas placer l’appareil sur , au-dessus ou à proximité de surfaces inflammables.
OM-216 244 Page 8 2-5. Princi pales norm es de sécur ité Safety in W elding, Cutting, and Allied Processes, ANSI Standard Z49.1, de Global Engineering Documents (téléphone : 1-877-413-5184, site In- ternet : www .
OM-216 244 Page 9 SECTION 3 − INTRODUCTION 3-1. Specifications Amperage Range in Max. Open- Circuit RMS Amps Input at Rated Load Output, 60 Hz 3-Phase at NEMA Load V oltages and Class I Rating Rated Welding Output Range in CC Mode Circuit V oltage 480 V 575 V KV A KW 1000 A at 36 VDC, 3-Phase 27% Duty Cycle 50 − 1000A 70 VDC 55 (0.
OM-216 244 Page 10 SECTION 4 − INSTALLATION - POWER SOURCE 4-1. Selecting a Location loc_2 3/96 - Ref. ST-151 556 / 803 618-B Y Special installation may be required where gasoline or volatile liquids are present − see NEC Article 51 1 or CEC Section 20.
OM-216 244 Page 1 1 4-2. Electrical Service Guide Y CAUTION: INCORRECT INPUT POWER can damage this welding power source. This welding pow- er source requires a CONTINUOUS supply of 60 Hz ( + 10%) power at + 10% of rated input voltage. Phase to ground voltage shall not exceed +10% of rated input voltage.
OM-216 244 Page 12 4-3. Weld Output Receptacles And Selecting Cable Sizes Y ARC WELDING can cause Electromagnetic Interference. T o reduce possible interference, keep weld cables as short as possible, close together , and down low , such as on the floor.
OM-216 244 Page 13 4-4. Connecting 3-Phase Input Power 2/04 - Ref. 802 136-A Y Installation must meet all National an d Local Codes − have only quali- fied persons make this installation. Y Disconnect and lockout/tagout in- put power before connecting input conductors from unit.
OM-216 244 Page 14 803 619-B 1 Circuit Breaker CB1 CB1 protects 60 volts ac portion of Remote 4 pin receptacle from overload. Press button to reset breaker . 1 4-5. Circuit Breaker 4-6. 4 Pin Receptacle Information 4 CONTROL Socket Socket Information 3 4 GUN CONTROL 1 2 Output to control of gun solenoid; 90 volts dc.
OM-216 244 Page 15 SECTION 5 − INSTALLATION - STUD GUN Y Disconnect gun from power source before installing or removing components. 1 Chuck 2 Chuck Adapter To install chuck, align chuck in front of chuck adapter. Tap firmly on the end of chuck to seat chuck into adapter.
OM-216 244 Page 16 Foot Installation 1 Leg Screw 2 Leg W asher 3 Ferrule Grip 4 Foot 5 Leg The foot is available in 3 different sizes (small, medium, and large) and 2 different configurations (closed and split). Typically, a split foot is only used when welding headed anchors and sheer connectors.
OM-216 244 Page 17 1 Leg Screw 2 Foot 3 Ferrule 4 Ferrule Grip 5 Stud . Alignment of the foot is very important, if the foot is not aligned properly it can create bad welds in the form of hang − ups. Place a stud into the chuck and a ferrule into the ferrule grip.
OM-216 244 Page 18 Plunge Settings When Using Ferrules Plunge controls the amount of stud that is melted during the arc time. Too much plunge and the f illet will overf ill the ferrule or create excessive splatter when using a spark shield. Too little plunge and there may be in- complete f illet formation.
OM-216 244 Page 19 Th e lift controls the arc length and is a factor in controlling the heat of the welding process. Lift should be set at 3/32 or .094 in (2.
OM-216 244 Page 20 SECTION 6 − OPERATION - POWER SOURCE Amperage Time (ms) POWER SELECT ADJUST OUTPUT ON READY WORK STUD GUN CONTROL 6-1. Front Panel Controls 232 187-A 1 1 Power Switch Use switch to turn unit On/Off.
OM-216 244 Page 21 Notes 16 Gauge (.063 in) 22 Gauge (.031 in) 24 Gauge (.025 in) 20 Gauge (.037 in) 18 Gauge (.050 in) 14 Gauge (.078 in) 1/8 in (.125 in) 3/16 in (.
OM-216 244 Page 22 6-2. Time/Amperage Control 1 T ime/Amperage Select Button Depress button to select T ime/Amperage control. 2 Time Meter 3 Amperage Meter 4 Time/Amp Adjustment Control Rotate knob clockwise to increase time/am- perage S Time - (5-1000 milliseconds) S Amperage - (50-1000 amps) Rotate knob counterclockwise to decrease time/amperage.
OM-216 244 Page 23 STUD COUNT READY OUTPUT ON ADJUST SELECT TIME AMPERAGE STUD COUNT READY OUTPUT ON ADJUST SELECT TIME AMPERAGE STUD COUNT READY OUTPUT ON ADJUST SELECT TIME AMPERAGE STUD COUNT READY OUTPUT ON ADJUST SELECT TIME AMPERAGE Ready Amperage Adjustment - Push select button once.
OM-216 244 Page 24 SECTION 7 − OPERATION - STUD GUN Y Disconnect gun from power source before installing or removing compo- nents. The stud gun automates the stud welding process.
OM-216 244 Page 25 7-3. W elding Sequence Gun is properely positioned and main gun spring is partially compressed. T rigger is pressed and the stud lifts off the work. An arc is created and melts the stud and parent material. After arcing is complete, the main spring plunges the stud into the molten pool of metal.
OM-216 244 Page 26 SECTION 8 − MAINTENANCE & TROUBLESHOOTING 8-1. Routine Maintenance Y Disconnect power before maintaining. . Maintain more often during severe conditions.
OM-216 244 Page 27 Notes.
OM-216 244 Page 28 8-3. Maintenance Procedures for Stud Gun When is Maintenance Required? Maintenance requirements will vary with environment and usage.
OM-216 244 Page 29 4 Chuck Adapter (2): Unscrew chuck adapter counter clockwise from cable clamp adapter . Important that chuck adapter is tight on cable clamp adapter to form a tight connection. An effective way of removing the adapter is to insert a round rod through two of the chuck eject holes.
OM-216 244 Page 30 8-4. T roubleshooting Help Aids 1 Stud Count LED 2 Ready LED 3 Output LED 803 618-B 2 3 1 Front Panel Error Indication Ready LED Status Possible Symptom Remedy Normal/None On No problem N/A HELP 1 Of f Malfunction in the primary power cir- cuit.
OM-216 244 Page 31 8-6. T roubleshooting - Stud Gun T rouble Remedy Hang up - Stud looks like it’s sitting on a pedestal with an hour glass shape Check alignment of the foot. a pe d es t a l w ith an h our g l ass s h ape Service the gun to ensure lift/release actions are functioning properly .
OM-216 244 Page 32 Notes.
OM-216 244 Page 33 SECTION 9 − ELECTRICAL DIAGRAMS 232 194-A Figure 9-1. Circuit Diagram For 460/575 V olt Models.
OM − 216 244 Page 34 SECTION 10 − P ARTS LIST FOR POWER SOURCE Ref. 803 724-C . Hardware is common and not available unless listed. Figure 10-1. Parts Assembly.
OM-216 244 Page 35 Description Part No. Dia. Mkgs. Item No. Figure 10-1. Parts Assembly Quantity 1 +224 966 Wrapper 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM − 216 244 Page 36 Description Part No. Dia. Mkgs. Item No. Figure 10-1. Parts Assembly (Continued) Quantity 44 207 725 Heat Sink, Power Module 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-216 244 Page 37 Notes SOCKET/WRENCH SELECTION T ABLE (U.S. ST ANDARD) SOCKET/WRENCH SELECTION T ABLE (METRIC) Specifications Socket or Wrench Size Specifications Socket or W rench Size Bolt Diameter Decimal Equivalent Bolt Nut Bolt Diameter U.S. Decimal Equivalent Bolt Nut 1/4 in .
OM − 216 244 Page 38 SECTION 1 1 − P ARTS LIST FOR STUD GUN 803 815-A . Hardware is common and not available unless listed. 1 2 3 4 5 6 8 7 12 13 14 11 10 23 9 24 4 25 27 26 29 30 28 27 22 23 33 35 36 37 32 31 34 15 16 17 18 19 20 21 38 40 41 42 39 Figure 1 1-1.
OM-216 244 Page 39 Description Part No. Dia. Mkgs. Item No. Figure 1 1-1. Parts Assembly Quantity 1 217 397 Front Cover Jam Nut 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM − 216 244 Page 40 SECTION 12 − OPTIONS AND ACCESSORIES 12-1.Plunge Dampener The plunge dampener controls how fast the melted stud drops into the molten weld pool. There are three typical dampeners: S Soft (D rating) S Medium (E rating) S Hard (F rating) Hard dampeners are typically only used for large diameter, extremely heavy studs.
Notes W or k l i k e a P r o ! Pros wel d and cut safel y . Read the safety rules at the beginni ng of this m anual..
Notes 229895 MA TERIAL THICKNESS GAUGE.
Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 2007 − 01 Y ou r distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours.
PRINTED IN USA © 2007 Miller Electric Mfg. Co. 2007 − 01 Miller Elect ric Mfg. Co. An Illinois T ool W orks Comp any 1635 West Spenc er S treet Applet on, W I 54914 USA International He adquarter s.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Miller Electric 625 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Miller Electric 625 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Miller Electric 625 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Miller Electric 625 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Miller Electric 625, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Miller Electric 625.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Miller Electric 625. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Miller Electric 625 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.