METROLOGIC INSTRUMENTS, INC. MS9535 Voyager BT ® Series Single-Line Hand Held Laser Scanner Installation and User's Guide.
Copyright © 2006 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in an y form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976.
ii T ABLE OF C ONTENTS Introduction Product Over view ............................................................................................. 1 Scanner and A ccessori es ...........................................................................
iii T ABLE OF C ONTENTS Indicato rs ........................................................................................................ 22 Audibl e ..................................................................................................
1 I NTRODUCTION MS9535 Voyager BT ® laser bar code scanner is a ne w member of Metrologic’s Voyager series. Besides featuring the patent ed technologies of an automa tic trigger and CodeGate, the Voyager BT has i ncorporated the latest Blueto oth ® wireless technology.
2 I NTRODUCTION Scanner and Accessories B ASI C K IT Part # Description MS9535-5 or MS9535-5M Voyager BT Scanner or Voyager BT Scanner with Memory 70-79004 x MS9535 VoyagerBT Wireless Hand Held Laser .
3 I NTRODUCTION Scanner and Accessories O PTIONAL A CCESSORIES Part # Description AC to DC Power Transformer- Regulated 5VDC @ 2 A Output 46-46881 Power Supply, China 46-46880 Power Supply, United Kin.
4 I NTRODUCTION Scanner Components Figure 1. Scanner Components Item # Description 1 Blue LED (see pages 23) 2 White LED (see pages 23) 3 Amber LED (see pages 23) 4 CodeGate Button 5 Output Window, La.
5 I NTRODUCTION Receiver/Charger Cradle Components Figure 2 Cradle Components Item # Description 1 Recesses for Wall Mount Hardware 2 Power and Communication Connectors 3 Cable Strain Relief Channel 4.
6 I NTRODUCTION Caution and Serial Number Labels The scanner and cradle hav e labels that provide important informatio n including; the model number, date of manufacture, serial num ber, safety and regulatory information. Figure 3 provides exam ples of these labels and their loc ations.
7 C RADLE I NSTALLATION TO THE H OST D EVICE RS232 and Light Pen 1. Turn off the host device. 2. Connect the 10-pin RJ45 male connector into the 10-pin modular jack on the bottom of the cradle. 3. Connect the 9-pin D-type Female connector of the RS232 cable to the proper COM port of the host device.
8 C RADLE I NSTALLATION TO THE H OST D EVICE Keyboard Wedge 1. Turn off the host device. 2. Connect the 10-pin RJ45 male connector into the 10-pin modular jack on the bottom of the cradle. 3. Disconnect the keyboard from host. 4. Connect the “Y” ends of the communication cable to the keyboard and keyboard port on the host device.
9 C RADLE I NSTALLATION TO THE H OST D EVICE Stand Alone Keyboard 1. Turn off the host system. 2. Connect the 10-pin RJ45 male connector into the 10-pin modular jack on the bottom of the cradle. 3. Connect the 6-pin Mini-DIN male connector of the keyboard cable to keyboard port on the host device.
10 C RADLE I NSTALLATION TO THE H OST D EVICE IBM 1. Turn off the host device. 2. Connect the 10-pin RJ45 male connector into the 10-pin modular jack on the bottom of the cradle. 3. Connect the IBM SDL connector to the IBM port on the host device. 4. Plug the power supply into the power jack on the bottom of the cradle.
11 C RADLE I NSTALLATION TO THE H OST D EVICE Low Speed USB Important Notes for Voyag er BT USB Interface Scanners In order for the Voyager BT to scan and char ge properly both the po wer supply and the USB communication ca ble must be attached before the host device is turned on.
12 C RADLE I NSTALLATION TO THE H OST D EVICE Low Speed USB 6. Turn on the host device. 7. Establish communicatio n between the sca nner and cradle. See page 15 for complete instructions on Establishing Bluetooth Communication bet ween the scanner and cradle.
13 C RADLE I NSTALLATION TO THE H OST D EVICE Full Speed USB (Powered by External Power Supply) 1. Turn off the host device. 2. Connect the 10-pin RJ45 male connector into the 10-pin modular jack on the bottom of the charger cradle. 3. Connect the USB A type connector to the USB port on the host device.
14 C RADLE I NSTALLATION TO THE H OST D EVICE Full Speed USB (Powered by the Host Device) 1. Turn off the host device. 2. Connect the 10-pin RJ45 male connector into the 10-pin modular jack on the bottom of the charger cradle. 3. Connect the female DC power jack of the USB cable to the center power jack on the bottom of the charger cradle.
15 E STABLISHING B LUETOOTH C OMMUNIC ATION Between the Scanner and the Cradle Bluetooth communication between the scan ner and cradle must be established before the Vo yagerBT can be used for normal op eration.
16 E STABLISHING B LUETOOTH C OMMUNIC ATION When the MS9535 Acts as a Client to Other Bluetooth Devices The MS9535 scanner can also link to other Bluetooth compatible devices such as a desktop computer, laptop computer, or printer. As a default, the MS9535 will act as the client to another Bluetoot h devic e.
17 E STABLISHING B LUETOOTH C OMMUNIC ATION When the MS9535 Acts as a Server to Other Bluetooth Devices Scan the Provide Service bar code b elow to enable the MS9535 to act as a server and be detected by another Blu e tooth device. This will allo w other Bluetooth devices to send inquiries to the scann er and attempt communication.
18 T HE MI9535-5 XX R ECEIVER / C HARGER C RADLE Charging Guidelines and Low Battery Indicators The scanner should be full y charged prior to being placed into service. Metrolog ic recommends that Bluetooth communication bet ween the scanner and the cradle be established first before charging.
19 T HE MI9535-5 XX R ECEIVER / C HARGER C RADLE Safety Precautions for Lithium Batteries • Do not place b atteries in fire or heat the batteries. • Do not store batteries near fire or other high temperature locations. • Do not store or carry batteries together with metal objects.
20 T HE MI9535-5 XX R ECEIVER / C HARGER C RADLE Communication Protocols The MI9535-5 xx crad le works as a receiver and a charger f or the MS9535. Receiver Once Bluetooth communication has been establish ed between the scanner and cradle, the cradle will act as a receiver for the barcode dat a transmitted from the scanner.
21 S CANNER O PERATION Modes of Operation Auto-Trigger Mode z Auto Trigger, In-Stand z Auto-triggers while in the stand z Bar code is automatically decoded and tra nsmitted CodeGate Mode z CodeGate, O.
22 S CANNER O PERATION Indicators Audible When the scanner is in operation, it provides audi ble feedback. T hese sounds indicate the status of the scanner . Eight settings are avail able for the tone of the beeper (normal, 6 alternate tones an d no tone).
23 S CANNER O PERATION Indicators Visual The MS9535 has three LED indicat ors (blue, white and amber) locat ed on the head of the scanner. When the scanner is in operation, th e flashing or stationary activity of the LEDs indicates the stat us of the scanner and the current scan.
24 S CANNER O PERATION Indicators Visual Alternating Fla shing of Blue and White This indicates the scanner is in configuration mode. T wo razzberry tones indicate that an invali d bar code has been scanned while in this mode . If the scanner is in RangeGate active mode, this indic ates the SRAM of the scanner becomes full.
25 S CANNER O PERATION Indicators Failure Modes Flashing Blue a nd one Razzberry Tone This indicates the scanner has experience d a laser sub-system failure. Return the unit for repair to an authorized servic e center. Flashing Blue and White w ith Two Razzberry Tones This indicates the scanner has experi enced a scanning mechanism failure.
26 S CANNER O PERATION Depth of Field by Bar Code Element Width* Minimum Bar Code Elemen t Width A B C D E F G H J K mm .13 .15 - - .19 - .25 .33 .53 - mils 5.2 5.7 - - 7.5 - 10 13 21 - Figure 12. Depth of Field by Bar Code Element W idth * All specifications are subj ect to change without notice.
27 S CANNER O PERATION IR Activation Range Figure 13. IR Activation Range * All specifications are subj ect to change without notice..
28 S CANNER O PERATION Cable Removal Before removing the cable from the scanner, Metrologic rec ommends that the power on the host device is off and the po wer supply has been disconn ected from the PowerLink cable 1. Locate the small ‘pin- hole’ on the bottom of the cradle near the cable.
29 T ROUBLESHOOTING G UIDE The following guide is for reference purpos es only. Contact a Metrologic representative at 1-800-ID-Metro or 1-800-43 6-3876 to preserve the limited warranty terms. Symptoms Possible Causes Solution The scanner has no LEDs, beeper or laser while seated in cradle.
30 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The scanner emits 3 beeps on power up. A non-volatile RAM failure may have occurred. Contact a Metrologic customer service representat ive, if the unit will not hold the configuration. The scanner emits a continuous razz tone on power – up.
31 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The scanner scans a bar code, but locks up after the first scan. The white LED stays on. The scanner is configured to support some form of host handshaking but is not receiving the signal.
32 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The scanner scans the bar code but there is no data. Make sure the scanner is configured for the appropriate mode. The scanner scans but the data is not correct. Make sure that the proper PC type AT, PS2 or XT is selected.
33 D ESIGN S PECIFICATIONS Scanner and Cradle Specif ications Operational Light Source: Visible Laser Diode 650 nm ± 10 nm Laser Power: 0.96 mW (peak) Depth of Scan Field: 0 mm – 203 mm (0” – 8”) 0.330 mm (13 mil) bar code at default setting Scan Speed: 72 ± 2 scan lines per second Scan Pattern: Single scan line Minimum Bar Width: 0.
34 D ESIGN S PECIFICATIONS Scanner and Cradle Specif ications Electrical Scanner: 5.2VDC ± 0.25V Input Voltage: Cradle: 5.0VDC ± 0.25V Cradle Power: 0.6 W Operating 1.15 W Scanner Power: Sleep 150 mW Operating 230 mA@5VDC Scanner Current: Sleep 30mA@ 5VDC Cradle Current: Cradle: 120 mA @ 5VDC DC Transformers: Class II; 5.
35 D EFAULT S ETTINGS - C OMMUNICATION P ARAMET ERS Many functions of the scanner and cradle ca n be “configured” – that is, enabled or disabled. The scanner and cradle are sh ipped from the factory configured to a set of default conditions. The default par ameter has an asterisk (*) in the charts on the following pages.
36 D EFAULT S ETTINGS - C OMMUNICATION P ARAMETERS Parameter Default RS232 Light Pen IBM 46XX KBW USB Mod 43 Check on Code 39 9 9 9 9 9 MSI-Plessey 10/10 Check Digit 9 9 9 9 9 MSI-Plessey Mod 10 Check.
37 D EFAULT S ETTINGS - C OMMUNICATION P ARAMETERS Parameter Default RS232 Light Pen IBM 46XX KBW USB Infinite Same sy mbol timeout 9 9 9 9 9 Inter-char acter delay Configurable in 1 msec steps (max 2.
38 D EFAULT S ETTINGS - C OMMUNICATION P ARAMETERS Parameter Default RS232 Light Pen IBM 46XX KBW USB UPC Prefix 9 9 9 UPC Suffix 9 9 9 Carriage Re turn * 9 9 9 Line Feed-Dis abled by default i n KBW .
39 D EFAULT S ETTINGS - C OMMUNICATION P ARAMET ERS Parameter Default RS232 Light Pen IBM 46XX KBW USB † Code Selects with Configur able Code Length Locks 3 avail 9 9 9 9 9 Configurable P refix char.
40 U PGRADING THE F LASH ROM F IRMWARE The MetroSet 2 program also allows the user of a Metrologic scanner to quickly upgrade to a new or custom version of soft ware. It requires the use of a personal computer running under Windo ws 95 or greater and the use of a communication port.
41 C RADLE AND C ABLE T ERMINATIONS Cradle Pinout Connections There are interface and p ower ports lo cated on the bottom of each MI953 5-5 xx cradle. The number of ports and t ype of connection varies by cradle model and the interface required.
42 C RADLE AND C ABLE T ERMINA TIONS Cradle Pinout Connections MI9535-538 Low Speed USB Port 10-Pin, RJ45 Pin Function 1 Ground 2 RS232 T ransmit Output 3 RS232 Rece ive Input 4 RTS Output 5 CTS Input 6 Reserved 7 Reserved 8 Reserved 9 Reserved 10 Shield Ground USB Type B Pin Function 1 VCC 2 D- 3 D+ 4 Ground Figure 18.
43 C RADLE AND C ABLE T ERMINA TIONS Cradle Pinout Connections MI9535C540 Full Speed USB 10-Pin, RJ45 Pin Function 1 Ground 2 RS232 T ransmit Output 3 RS232 Rece ive Input 4 RTS Output 5 CTS Input 6 D+ 7 USB +5V 8 D- 9 Reserved 10 Shield Ground Figure 20.
44 C RADLE AND C ABLE T ERMINA TIONS Cable Connector Configurations (Host End) RS232/Light Pen Cable MLPN 54-54000x-N Pin Function 1 Shield Ground 2 RS232 T ransmit Output 3 RS232 Rece ive Input 4 DT .
45 C RADLE AND C ABLE T ERMINA TIONS Cable Connector Configurations Full Speed USB Cable with power from Register MLPN 54 -54073x Pin Function 1 +5VDC 2 D- 3 D+ 4 Ground 5 Ground 6 +12V 7 +12V 8 Groun.
46 C RADLE AND C ABLE T ERMINATIONS Cable Connector Configurations Keyboard Wedge Po werLink Cable 54-54002 x -3 Pin Function 1 Keyboard Clock 2 Keyboard Data 3 No Connect 4 Power Ground 5 +5 Volts DC.
47 R EGULATORY C OMPLIAN CE Safety ITE Equipment IEC 60950-1, EN 60950-1 Laser Laser Class 1: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2 Caution Use of controls or adjustments or performan ce of procedures other t han those specified herein may result in hazardous laser light exposure.
48 R EGULATORY C OMPLIAN CE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022, EN300 328 V1.6. 1, EN301 489-17 V1.2.1 Immunity CISPR 24, EN 55024 Changes or modifications not expressly approved by the party respo nsible for compliance could void the user’s authority to operate the equipment.
49 R EGULATORY C OMPLIAN CE EMC Changes or modifications not expressly approved by the party respo nsible for compliance could void the user’s authority to operate the equipment.
50 L IMITED W ARRANTY The MS9535 VoyagerBT ® scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A facility and its Suzhou, China facility. The MS9535 VoyagerBT scanners have a two (2) year limited warranty from the date of manufacture.
51 P ATENTS For patent information, please refer to www.honeywellaidc.com/patents ..
52 I NDEX A AC .................................. see power accessories ............................... 2, 3 address bar code ......... 5, 15, 16, 17 amber LED .................. see indicator authentic ate ................................. 39 B battery .
53 I NDEX pin-ho le........................................ 28 pinout .................................... 41– 46 power..................... 3, 18, 19, 33, 34 R range ................... 21, 26, 27, 34, 35 RangeGate ............................ 21, 39 razzberry tone .
54.
.
November 2006 Version 0 1 Printed in the USA 7 0 -7 9 0 0 4 F.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Metrologic Instruments MS9535 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Metrologic Instruments MS9535 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Metrologic Instruments MS9535 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Metrologic Instruments MS9535 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Metrologic Instruments MS9535, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Metrologic Instruments MS9535.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Metrologic Instruments MS9535. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Metrologic Instruments MS9535 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.