Vai alla pagina of 34
MDG50PCC Install a tion Manual 50 lb Sin g le P o c k et / Phase 7 / Coin Part No. 1 13198 - 5 A VERTISSEMENT : Assurez-vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d’incendie ou d’explosion ou pour éviter tout dommage matériel, toute blessure ou la mort.
“IMPORT ANT NO TE T O PURCHASER” Information must be obtained from your local gas supplier on the instructions to be followed if the user smells gas.
IMPOR T ANT YOU MUST DISCONNECT AND LOCK OUT THE ELECTRIC SUPPL Y AND THE GAS SUPPL Y OR THE STEAM SUPPL Y BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINE T O ALLOW ACCESS FOR CLEANING , ADJUSTING , INST ALLA TION, OR TESTING OF ANY EQUIPMENT PER OSHA (Occupational Safety and Health Administration) ST ANDARDS.
W ARNING The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJURY OR FIRE COULD RESUL T . IMPOR T ANT PLEASE OBSER VE ALL SAFETY PRECAUTIONS displayed on the equipment and/or specified in the installation manual included with the dryer .
Table of Contents SECTION I SAFETY PRECAUTIONS .................................................................................................................. 2 SECTION II SPECIFICA TIONS ............................................................
2 Maytag Co. 1 13198 - 5 SECTION I SAFETY PRECAUTIONS W ARNING: For your safety , the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury , or loss of life. W ARNING: The dryer must never be operated with any of the back guards, outer tops, or service panels removed.
1 13198 - 5 Maytag Co. 3 7. A program should be established for the inspection and cleaning of lint in the burner area, exhaust ductwork, and area around the back of the dryer . The frequency of inspection and cleaning can best be determined from experience at each location.
4 Maytag Co. 1 13198 - 5 M AXI M U M CAPACI T Y ( DR Y W EI G H T ) 50 l bs 22. 7 kg BASKET ( T U M BL ER ) DI AM ET ER 32 - 3/ 4” 83. 2 cm BASKET ( T U M BL ER ) DEPT H 37 - 1/ 2” 95. 3 cm BASKET ( T U M BLER ) M O T O R 3/ 4 h p 0. 560 kW DO O R O PE N I N G ( D I A M ET E R ) 21- 1/ 2” 54.
1 13198 - 5 Maytag Co. 5 NOTE: Manufacturer reserves the right to make changes in specifications at any time without notice or obligation. SPECIFICA TIONS – GAS ONL Y.
6 Maytag Co. 1 13198 - 5 SECTION III INST ALLA TION PROCEDURES Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.
1 13198 - 5 Maytag Co. 7 4. Provisions for adequate air supply must be provided as noted in this manual (refer to Fresh Air Supply Requirements in Section D ). 5. Clearance provisions must be made from combustible construction as noted in this manual (refer to Dryer Enclosure Requirements in Section C ).
8 Maytag Co. 1 13198 - 5 NOTE: Air considerations are important for proper and efficient operation. Dryers may be positioned sidewall to sidewall. However , a 1/16” (1.59 mm) minimum allowance must be made for opening and closing of the control door .
1 13198 - 5 Maytag Co. 9 E. EXHAUST REQUIREMENTS Exhaust ductwork should be designed and installed by a qualified professional. Improperly sized ductwork will create excessive back pressure, which res.
10 Maytag Co. 1 13198 - 5 NOTE: Ductwork should be laid out in such a manner where allowances are made at rear area of the dryer for removal of rear service panels or guards. SINGLE DR YER VENTING HORIZONT AL VENTING When a single 8-inch (20.32 cm) horizontal vent is used, the ductwork to the outlet cannot exceed 20 feet (6.
1 13198 - 5 Maytag Co. 11 MUL TIPLE DR YER (COMMON) VENTING If it is not feasible to provide separate exhaust ducts for each dryer , ducts for individual dryers may be channeled into a common main duct. Each dryer is provided with a back draft damper .
12 Maytag Co. 1 13198 - 5 GAS ELECT R I CAL SER VI CE S PECI FI C AT I O N S ( PER DR Y ER ) NOTES : A . B. Wh en fu ses ar e u sed t h ey mu s t b e du al elem en t, tim e del ay , cu rr en t l imit in g, c l ass R K 1 or R K 5 ON LY .
1 13198 - 5 Maytag Co. 13 IMPOR T ANT : Figures shown are for non-reversing models only . For reversing models contact the factory . 3. Grounding A ground (earth) connection must be provided and installed in accordance with state and local codes.
14 Maytag Co. 1 13198 - 5 A ground lug is provided in the rear electrical box to connect your service ground. G . GAS INFORMA TION It is your responsibility to have ALL plumbing connections made by a qualified professional to ensure that the gas plumbing installation is adequate and conforms to local and state regulations or codes.
1 13198 - 5 Maytag Co. 15 T Y P E OF GAS Li qu i d Pro pan e Con v er si on Ki t Par t Nu m ber B tu/ ho ur Ra ti n g kcal / hr Rat i ng N at u r al Li qu i d P ropan e Qty .
16 Maytag Co. 1 13198 - 5 3. Piping Connections ALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LA TEST EDITION, or in Canada, CAN/CGA-B149.
1 13198 - 5 Maytag Co. 17 NOTE: A water column test pressure of 3.5 inches (8.7 mb) for natural gas and 10.5 inches (26.1 mb) for liquid propane (L.P .) dryers is required at the gas valve pressure tap of each dryer for proper and safe operation. A 1/8” N.
18 Maytag Co. 1 13198 - 5 I. PREOPERA TIONAL TESTS ALL dryers are thoroughly tested and inspected before leaving the factory . However , a preoperational test should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit or due to marginal location (installation) conditions.
1 13198 - 5 Maytag Co. 19 6. The dryer should be operated through one (1) complete cycle to ensure that no further adjustments are necessary and that ALL components are functioning properly . BASKET (TUMBLER) COA TING The basket (tumbler) is treated with a protective coating.
20 Maytag Co. 1 13198 - 5 SECTION IV SER VICE/P AR TS INFORMA TION A. SER VICE Service must be performed by a qualified trained technician, service agency , or gas supplier . If service is required, contact the dealer from whom the Maytag equipment was purchased.
1 13198 - 5 Maytag Co. 21 SECTION V W ARRANTY INFORMA TION A. RETURNING W ARRANTY CARDS Before any dryer leaves the manufacturer ’ s test area, a warranty card is placed on the back side of the main door glass.
22 Maytag Co. 1 13198 - 5 SECTION VI ROUTINE MAINTENANCE A. CLEANING A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from various areas of the dryer , as well as throughout the ductwork system. The frequency of cleaning can best be determined from experience at each location.
1 13198 - 5 Maytag Co. 23 W ARNING: THE ACCUMULA TION OF LINT IN THE EXHAUST DUCTWORK CAN CREA TE A POTENTIAL FIRE HAZARD. W ARNING: DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND VENTILA TION AIR. W ARNING: INSPECT AND REMOVE ANY LINT ACCUMULA TION, WHICH CAN CAUSE THE BACK DRAFT DAMPER TO BIND OR STICK.
24 Maytag Co. 1 13198 - 5 D. LINT DRA WER REMOV AL T o remove the lint drawer from the dryer pull drawer out approximately halfway . Rotate/move lint drawer stop hinge (refer to the illustration below ) downward and pull the drawer out.
1 13198 - 5 Maytag Co. 25 SECTION VII DA T A LABEL INFORMA TION When contacting the Maytag dealer certain information is required to ensure proper service/parts information. This information is on the data label af fixed to the left side panel area behind the top control (access) door .
26 Maytag Co. 1 13198 - 5 SECTION VIII PROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENT COMPONENTS 1. Microprocessor Controller (Computer) Board a . Upon completing installation of the replacement microprocessor controller (computer) board, reestablish power to the dryer .
1 13198 - 5 Maytag Co. 27 2. For Models with Direct Spark Ignition (DSI) Module (T ype I) Theory of Operation: Start the drying cycle. When the gas burner ignites within the chosen trial for ignition time (6-seconds), the flame sensor detects gas burner flame and signals the DSI module to keep the gas valve open as long as there is a call for heat.
28 Maytag Co. 1 13198 - 5 SECTION IX MANUAL RESET BURNER HI-LIMIT INSTRUCTIONS This dryer was manufactured with a manual reset burner hi-limit thermostat, which is monitored by the Phase 7 computer .
1 13198 - 5 Maytag Co. 29 Notes _____________________________________________________________________________________________________________________ __________________________________________________.
Part No. 1 13198 5 - 09/2 4 /08 - 0.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Maytag MDG50PCC è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Maytag MDG50PCC - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Maytag MDG50PCC imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Maytag MDG50PCC ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Maytag MDG50PCC, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Maytag MDG50PCC.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Maytag MDG50PCC. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Maytag MDG50PCC insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.