POR T ABLE GASOLINE G E N E RA TO RS OWNER’S OPERA TION AND INST ALLA TION MANUAL R IMPORT ANT: Read and under stand this man ual before operating or ser vic- ing generator . Impr oper use of g enerator can cause serious injur y . Keep this manual f or future reference.
2 117846 POR T ABLE GASOLINE GENERA TORS R 1. Gasoline presents a hazard of fire or explosion. Gasoline is flammable. Its v apor is explosi ve. • Keep fuel out of children’ s reach. • Refuel generator in a well-vented area. Do not fill fuel tank in the dark.
3 117846 OWNER’S MANUAL E F FU EL 2 0 2 0 3 0 3 0 4 5 4 5 R ES E T T E ST E F F U E L 9. On ly a qu al ifi ed ele ct ri ca l s er vi ce per so n sho uld se rvi ce and rep air ge ner ato r. • Generator produces high voltage. Use extreme caution when working on electrical parts.
4 117846 POR T ABLE GASOLINE GENERA TORS R VENTILA TION DUST , DIR T , RAIN, AND SNOW HIGH AND LOW TEMPERA TURE OPERA TION Air tem perature affect s genera tor outp ut. Ou tpu t dro ps 1% for eac h 10° temp er at ure rise ab o ve 60° F. Ve r y lo w te mp era tu res may mak e the engi ne ha rd to st art .
5 117846 OWNER’S MANUAL * Single-phase, 1.0 po wer f actor MODEL MGH10000C MGH8500AIE Electrical Rated W attage ......................... 10,000 ............................ 8500 Rated Amperage 120 V .................................... 83.3 .......
6 117846 POR T ABLE GASOLINE GENERA TORS R ENGINE CIRCUIT BREAKER This fuse protects the battery charging cir- cuit. A short circuit will trip the break the fuse. The fuse will also break if you install battery wrong. Replace fuse if engine will not start.
7 117846 OWNER’S MANUAL ENGINE OIL W e ship the generator without oil in the engine crankcase. Y ou must add oil before starting engine. See engine owner’ s manual for specific oil type. CHECKING OIL LEVEL AND ADDING OIL Follo w steps below to check oil lev el.
8 117846 POR T ABLE GASOLINE GENERA TORS R Ampere A WG for Length of Load Cord in Feet 50' 100' 150' 2 18 18 18 3 18 18 18 4 16 16 16 5 16 16 16 6 16 16 14 8 16 14 12 10 16 14 12 12 14 .
9 117846 OWNER’S MANUAL 1 2 0 / 2 4 0 V T W IS T L O C K 1 2 0 / 2 4 0 V T W IS T L O C K 1 2 0 V T W I S T L O C K 1 2 0 V G F C I 1 2 0 V H O U R M E T E R A U T O - I D L E R E S E T R E S E T R .
10 117846 POR T ABLE GASOLINE GENERA TORS R Running Starting Equipment W atts W atts 1/2" Drill 1000 1250 T oaster 1200 1200 Coff ee maker 1200 1200 Skillet 1200 1200 14" Chain saw 1200 1500.
11 117846 OWNER’S MANUAL Reset Reset Reset Reset Reset Reset 120 Vo lt A u t o Id l e 2 0 0 V p ;t S e l e c t o r O ff O n RESE T TEST E N M 0 0 0 0 0 0 0 5 HOURS 1/10 Reset Reset Reset Reset Reset.
12 117846 POR T ABLE GASOLINE GENERA TORS R HONDA OFF ON STAR T ENGINE SW Figure 18 - Engine Switch Engine Switch 2 0 2 0 3 0 3 0 4 5 4 5 R ES E T T E ST E F F U E L OPERA TION Continued Figure 17 - C.
13 117846 OWNER’S MANUAL Reset Reset Reset Reset Reset Reset 120 Vo lt A u t o Id l e 2 0 0 V p ;t S e l e c t o r O ff O n RESE T TES T E N M 0 0 0 0 0 0 0 5 HOURS 1/10 OPERA TION Continued A UT O-IDLE OPERA TION IMPOR T ANT : Ne ver start engine with elec- trical loads connected.
14 117846 POR T ABLE GASOLINE GENERA TORS R MAINTENANCE AND REP AIRS W ARNING: Only a qualified electrical service person should service and repair the alternator on thi s gen er ato r . Us e onl y fac to ry appro ved replacement par ts. HIGH AL TITUDE OPERA TION This generator will not perform well at high altitudes without proper adjustment.
15 117846 OWNER’S MANUAL TROUBLESHOOTING W ARNING: Onl y a qualified electrical ser vice person should service and repair generator . Use only factory appro ved replacement parts. POSSIBLE CA USE 1. Defectiv e capacitor 2 . W inding short circuit or loose connections 3.
16 117846 POR T ABLE GASOLINE GENERA TORS R WIRING DIAGRAMS Resistance in Ohms Stator Stator Rotor Capacitor , Main Auxiliary Primary MFD Diodes (2) Model Winding * Winding Δ Winding † 450 V olt 800 V olt MGH8500AIE 0.41 .098 7.81 45 8 Amp MGH10000C 0.
17 117846 OWNER’S MANUAL Red Y e llo w Green/Y ellow Gr n/ Ylw Gr n/ Ylw Grn/ Ylw Green/ Y e llo w Green/ Y ello w Green/Y ello w Green/ Y ello w Green/ Y ello w T o Roll Cage T o Alternator Ground .
18 117846 POR T ABLE GASOLINE GENERA TORS R ILLUSTRA TED P ARTS LIST For Model MGH8500AIE Fuel T ank and Roll Cage 120/24 0V TWISTL OCK 120/24 0 V TWISTL OCK 120V TWISTL OCK 120V GFCI 120 V HOUR M ETE.
19 117846 OWNER’S MANUAL * A v ailable at an y hardware store. ILLUSTRA TED P ARTS LIST For Model MGH8500AIE Fuel T ank and Roll Cage This list contains replaceable parts used in your generator . When ordering parts, follow the instructions listed under Replacement P arts on page 25 of this manual.
20 117846 POR T ABLE GASOLINE GENERA TORS R 23 20 29 36 26 10 20 28 12 10 16 27 2 20 10 10 25 10 9 35 1 7 3 6 5 6 9 10 4 9 10 36 9 24 22 8 12 11 25 20 10 10 21 21 19 19 18 32 9 31 34 30 33 18 FUEL F 1.
21 117846 OWNER’S MANUAL ILLUSTRA TED P ARTS LIST For Model MGH10000C Fuel T ank and Roll Cage This list contains replaceable parts used in your generator . When ordering parts, follow the instructions listed under Replacement P arts on page 25 of this manual.
22 117846 POR T ABLE GASOLINE GENERA TORS R ILLUSTRA TED P ARTS LIST For Model MGH8500AIE Control P anel This list contains replaceable parts used in your generator . When ordering parts, follow the instructions listed under Replacement P arts on page 25 of this manual.
23 117846 OWNER’S MANUAL † Includes reference n umbers 1 through 16 ‡ Not shown Reset Reset Reset Reset Reset Reset 120 Vo lt A u t o Id l e 2 0 0 V p ; t S e l e c t o r O ff O n P 4 P 3 P 2 P .
24 117846 POR T ABLE GASOLINE GENERA TORS R 1 2 3 6 5 4 8 9 10 7 1 1 12 15 16 17 13 14 ILLUSTRA TED P ARTS LIST For Models MGH8500AIE and MGH10000C Alternator Assembl y This list contains replaceable parts used in your generator . When ordering parts, follow the instructions listed under Replacement P arts on page 25 of this manual.
25 117846 OWNER’S MANUAL P ARTS CENTRALS These Parts Centrals are priv ately o wned businesses. They hav e agreed to support our customer’ s needs by providing original replacement parts and accessories.
26 117846 POR T ABLE GASOLINE GENERA TORS R NOTES ________________________________________________________________________________________________ _____________________________________________________.
27 117846 OWNER’S MANUAL NOTES ________________________________________________________________________________________________ ______________________________________________________________________.
KEEP THIS W ARRANTY W ARRANTY INFORMA TION FIVE-YEAR LIMITED W ARRANTY GASOLINE PORT ABLE GENERA TORS DESA Specialty Products™ makes no warranty with respect to the engine and engine components not of its manuf ac- ture. The y are subject to warranties of their manufacturers.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Master Lock MGH10000C, MGH8500AIE è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Master Lock MGH10000C, MGH8500AIE - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Master Lock MGH10000C, MGH8500AIE imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Master Lock MGH10000C, MGH8500AIE ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Master Lock MGH10000C, MGH8500AIE, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Master Lock MGH10000C, MGH8500AIE.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Master Lock MGH10000C, MGH8500AIE. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Master Lock MGH10000C, MGH8500AIE insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.