R G 011 Models: B30, B70, B100, B150 IMPORTANT Read and understand this manual before assembling, starting or servicing heater. Improper use of heater can cause serious injury.
100743 2 Safety Information ......................................................................... 3 Product Identification .................................................................... 4 Unpacking ..........................................
3 100743 SAFETY INFORMA TION ! W ARNINGS IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.
100743 4 Fuel Cap Lower Shell Power Cord Upper Shell Figure 3 - 150,000 BTU/Hr Model Handle Fuel Cap Lower Shell Side Cover Fuel Tank Figure 1 - 30/70,000 BTU/Hr Models Side Cover Fuel Tank Lower Shel.
5 100743 UNP A CKING 1. Remove all packing items applied to heater for shipment. 2. Remove all items from carton. 3. Check items for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater. ASSEMBL Y (For 90,000 and 150,000 BTU/Hr Models Only) These models are furnished with wheels and handles.
100743 6 THEOR Y OF OPERA TION The Fuel System: The air pump forces air through the air line. The air is then pushed through the burner head nozzle. This air causes fuel to lift from the tank. A fi ne mist of fuel is sprayed into the combustion chamber.
7 100743 VENTILA TION ! W ARNING Follow the minimum fresh, outside air ventilation requirements. If proper fresh, outside air ventilation is not provided, carbon monoxide poisoning can occur. Provide proper fresh, outside air ventilation before running heater.
100743 8 OPERA TION Continued Figure 8 - Flame-Out Control Reset Button, 150,000 BTU/Hr (Optional Extra) Continued PREVENT A TIVE MAINTENANCE SCHEDULE Item How Often How To Fuel tank Flush every 150-200 hours See Storage above. of operation or as needed.
9 100743 Continued Item How Often How To Spark plug Clean and regap every 600 See Spark Plug , pages 12 and 13. hours operation or replace as needed. Fan blades Clean every season or as needed.
100743 10 150 SHELL REMOVAL EA/EB Euro PV 020 Upper Shell Fan Guard Figure 12 - Fuel Filter Removal, 30/70,000 BTU/Hr Models Figure 11 - Upper Shell Removal, 150,000 BTU/Hr Model Figure 9 - Upper Shell Removal, 30/70,000 BTU/Hr Models Figure 10 - Upper Shell Removal, 90,000 BTU/Hr Model Side Cover Fuel Filter (30/70,000 BTU/Hr Models) 1.
11 100743 150 FUEL FILTER REMOVAL PFA/P 043 Fuel Filter (90,000 BTU/Hr Model) 1. Remove side cover screws using 5/16" nut-driver. 2. Remove side cover. 3. Pull upper fuel line off fuel fi lter neck. 4. Carefully pry bushing, lower fuel line, and fuel fi lter out of fuel tank.
100743 12 Spark Plug (30,000 BTU/Hr Model) 1. Remove upper shell (see page 10). 2. Remove fan (see page 19). 3. Remove fuel and air line hoses from nozzle assembly. 4. Remove spark plug wire from spark plug. 5. Remove two screws using 5/16" nut-driver and remove burner strap.
13 100743 Spark Plug (70/90/150,000 BTU/Hr Models) 1. Remove upper shell (see page 10). 2. Remove fan (see page 19). 3. Remove spark plug wire from spark plug. 4. Remove spark plug from burner head using 13/16" open-end wrench. 5. Clean and regap spark plug electrodes to .
100743 14 Air Output, Air Intake, and Lint Filters 1. Remove upper shell (see page 10). 2. Remove filter end cover screws using 5/16" nut- driver. 3. Remove filter end cover. 4. Replace air output and lint filters. 5. Wash or replace air intake filter (see Preventative Maintenance Schedule, page 8).
15 100743 Nozzle (30,000 BTU/Hr Model) 1. Remove upper shell (see page 10). 2. Remove fan (see page 19). 3. Remove fuel and air line hoses from nozzle assem- bly. 4. Turn nozzle assembly 1/4 turn to left and pull toward motor to remove. 5. Place plastic hex-body into vise and lightly tighten.
100743 16 Nozzle (70/90,000 BTU/Hr Models) 1. Remove upper shell (see page 10). 2. Remove fan (see page 19). 3. Remove fuel and air line hoses from burner head. 4. Remove spark plug wire from spark plug. 5. Remove spark plug from burner head using 13/16" open-end wrench.
17 100743 Nozzle (150,000 BTU/Hr Model) 1. Remove upper shell (see page 10). 2. Remove fan (see page 19). 3. Remove spark plug wire from spark plug. 4. Remove spark plug from burner head using 13/16" open-end wrench. 5. Loosen flare nut using 3/4" open-end wrench.
100743 18 Pump Rotor (Procedure if rotor is binding) 1. Remove upper shell (see page 10). 2. Remove filter end cover screws using 5/16" nut- driver. 3. Remove filter end cover and air filters. 4. Remove pump plate screws using 5/16" nut- driver.
19 100743 Fan IMPORTANT: Remove fan from motor shaft before removing motor from heater. The weight of the motor resting on the fan could damage the fan pitch. 1. Remove upper shell (see page 10). 2. Use 1/8" allen wrench to loosen setscrew which holds fan to motor shaft.
100743 20 WIRING DIA GRAMS Ignitor White Brown Blue Green/Yellow Photocell Spark Plug Flame- Out Control B Reset Button R Red Blue White Blue White Red Red Orange Terminal Board Motor Green/ Yellow Re.
21 100743 WIRING DIA GRAMS Blue Green/Yellow 230V/50Hz White Red Orange Terminal Board Ignitor Spark Plug Motor Green/ Yellow Brown Red Orange Figure 40 - Wiring Diagram, 30,000 BTU/Hr EEI Model Ignit.
100743 22 A CCESSORIES Purchase accessories from your local dealer. AIR GAUGE KIT - HA1180 For all models. Special tool to check pump pressure. HEAVY DUTY WHEELS AND HANDLE KIT - HA1202 For heavy duty applications. Makes your heater even more portable and convenient.
23 100743 ILLUSTRA TED PA R T S BREAKDO WN WHEELS AND HANDLES FOR 90,000 AND 150,000 BTU/Hr MODELS KEY PART PART 90,000 150,000 NO. NUMBER DESCRIPTION QTY.
100743 24 ILLUSTRA TED PA R T S BREAKDO WN 30,000 BTU/Hr 18-1 18-2 18-3 18-4 18-5 18-6 18-7 18-8 18-9 18-10 18-11 18-12 18-13 18-14 18-15 18-16 18-17 18-18 Motor and Pump Assembly 1 2 3 4 5 6 7 8 9 11.
25 100743 This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. P ARTS LIST 30,000 BTU/Hr KEY PART PART NO.
100743 26 ILLUSTRA TED PA R T S BREAKDO WN 70,000 BTU/Hr 18-1 18-2 18-3 18-4 18-5 18-7 18-8 18-9 18-10 18-11 18-12 18-14 18-15 18-16 18-18 18-17 18-6 PFA/P 007 MOTOR & PUMP 70 EAI/EBI 18-13 Motor .
27 100743 P ARTS LIST 70,000 BTU/Hr This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part.
100743 28 1 2 3 4 5 7 8 9 10 11 12 13 14 15 16 (2) 17 18 19 20 25 26 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 6 21 22 23 24 45 44 27 28 PFA/P 010 MOTOR & PUMP 100 EAI/EBI ILLUSTRA TED PA R T S.
29 100743 P ARTS LIST 90,000 BTU/Hr This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part.
100743 30 1 2 3 4 5 7 8 9 10 11 12 13 14 15 16 17 18 19 20 22 9 23 24 25 26 27 28 29 30 31 13 32 9 32 33 34 9 35 36 37 40 41 42 43 9 45 47 9 48 44 49 50 51 32 52 6 39 38 21 53 9 54 55 46 BURNER HEAD 1.
31 100743 This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. P ARTS LIST 150,000 BTU/Hr KEY PART PART NO.
100743 32 W ARRANTY AND REP AIR SER VICE POSE. IN ANY EVENT IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PAR- TICULAR PURPOSE ARE LIMITED TO THE DURATION OF THIS EXPRESS WARRANTY. Any transportation charges, costs of installation, duty, taxes or any other charges whatsoever must be borne by the user.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Master Lock B150 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Master Lock B150 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Master Lock B150 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Master Lock B150 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Master Lock B150, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Master Lock B150.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Master Lock B150. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Master Lock B150 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.