® ® Revision 1.0 Page i TMP100 Temperature Module User’s Manual Revision 1.0 Copyright © 2008 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N.
TMP100 User's Manual Page ii Revision 1.0 Revision History Revision Description 1.0 Original document.
® ® Revision 1.0 Page iii Table of Contents 1 Introduc tion .................................................................................................................. ......... 1 1.1 Firmware Revi sion ...........................
TMP100 User's Manual Page iv Revision 1.0 Table of Appendices Appendix A – NMEA 2000 ® Interfacing ............................................
® ® Revision 1.0 Page 1 1 Introduction Congratulations on your purchase of the Ma retron Temperature Modul e. Maretron has designed and built your TMP 100 to the highest standards for years of dependable and accurate service.
TMP100 User's Manual Page 2 Revision 1.0 - Ambient Air Temperature Probe (-20° C to 80°C or -4°F to 176°F) - Ring Terminal Probe (-20°C to 80°C or -4°F to 176°F) - Immersion Probe for Tanks or Plenums (-20°C to 80°C or -4°F to 176°F) - Exhuast Gas Temperature Probe (0°C to 900°C or 32° to 1652°F) 1.
® ® Revision 1.0 Page 3 2.3 Mounting the TMP100 Attach the TMP100 securely to the vessel usi ng the included stainle ss steel mounting screws or other fasteners as shown in Figure 1 below .
TMP100 User's Manual Figure 2 – NMEA 2000 ® Connector Face Views 2.4.2 Temperature Probe Connections The TMP100 temperature probe connections are made by connecting to the 12-pin terminal strip on the top of the unit. First, remove the f our screws at the corners of the unit detaching the splash guard from the unit.
® ® 2.4.2.1 Exhaust Gas Temperature (EGT) Probe The TP-EGT-1 exhaust gas temper ature probe may be used to measure temperatures other than exhaust gas temperatures; however, the TP -EGT-1 exhaust gas temperature probe is the only TMP100 temperature probe that has su fficient range to measure exhaust gas temperature.
TMP100 User's Manual Please refer to Figure 4 for connecting the TMP100 to a TR3K ring/under bolt thermistor temperature probe, TP-AAP-1 ambient air te mperature probe, or TP-IP-1 immersion temperature probe.
® ® Revision 1.0 Page 7 Temperature, Inside Tem perature, Engine Room Te mperature, Main Cabi n Temperature, Live Well Temperature, Bait Well Te mperature, Refrigeration Te mperature, Heating System Temperature, Freezer Temper ature, Exhaust Gas Temper ature, and User Defined Temperature #129-#144.
TMP100 User's Manual Page 8 Revision 1.0 2.5.5.3 Installation Description… The TMP100, along with all other Level A certified NMEA 2000 devices, has two user- programmable installation description fields.
® ® Revision 1.0 Page 9 5 Technical Specifications As Maretron is constantly impr oving its products, all specificat ions are subject to change without notice.
TMP100 User's Manual Page 10 Revision 1.0 128723 Temperature, High Range (Exhaust Gas Temperatur e) 0.5 times/second Electrical Parameter Value Comment Operating Voltage 9 to 32 Volts DC Voltage Power Consumption 50 mA NMEA 2000 ® Interface Load Equivalence Number (LEN) 1 NMEA 2000 ® Spec.
® ® 7 Installation Template Please check the dimensions before using the fo llowing diagram as a template for drilling the mounting holes because the printing proc ess may have distorted the dimensions. Figure 5 – Mounting Surface Template Revision 1.
TMP100 User's Manual Page 12 Revision 1.0 8 Maretron (2 Year) Limited Warranty Maretron warrants the TMP100 to be free from defects in materials and workm anship for t wo (2) years from the date of original purchase.
® ® Revision 1.0 Appendix A – NMEA 2000 Interfacing Page A1 Appendix A – NMEA 2000 ® Interfacing TMP100 NMEA 2000 ® Periodic Data Transmitted PGNs PGN 130310 – Environmental Parameters ( not.
TMP100 User's Manual Page A2 Appendix A – NMEA 2000 Interfacing Revision 1.0 PGN 130312 –Temperature The TMP100 uses this PGN to provide a regul ar transmission of various temperatures. The factory default for periodic transmission rate is once every two seconds.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Maretron TMP100 Exhaust Gas Temperature Probe TP-EGT-1 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Maretron TMP100 Exhaust Gas Temperature Probe TP-EGT-1 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Maretron TMP100 Exhaust Gas Temperature Probe TP-EGT-1 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Maretron TMP100 Exhaust Gas Temperature Probe TP-EGT-1 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Maretron TMP100 Exhaust Gas Temperature Probe TP-EGT-1, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Maretron TMP100 Exhaust Gas Temperature Probe TP-EGT-1.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Maretron TMP100 Exhaust Gas Temperature Probe TP-EGT-1. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Maretron TMP100 Exhaust Gas Temperature Probe TP-EGT-1 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.