Revision 1.0 Page i ® ® RIM100 Run Indicator Module User’s Manual Revision 1.0 Copyright © 2008 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N.
RIM100 User's Manual Page ii Revision 1.0 Revision History Revision Description 1.0 Original document.
Revision 1.0 Page iii ® ® Table of Contents 1 Introduc tion .................................................................................................................. ......... 1 1.1 Firmware Revi sion ...........................
.
Revision 1.0 Page 1 ® ® 1 Introduction Congratulations on your purchase of the Maretron Run Indicator Module (RIM100). Maretron has designed and built your RIM100 to the hi ghest standards for years of dependable and accurate service.
RIM100 User's Manual Page 2 Revision 1.0 3. Mount the RIM100 (Section 2.3 ) 4. Connect the RIM100 (Section 2.4 ) 5. Configure the RIM100 (Section 2.
Revision 1.0 Page 3 ® ® 2.3 Mounting the RIM100 Attach the RIM100 securely to the vessel usi ng the included stainle ss steel mounting screws or other fasteners as shown in Figure 1 below .
RIM100 User's Manual Figure 2 – NMEA 2000 ® Connector Face Views 2.4.2 Monitored Load Connections The RIM100 monitored load connections are made by connecting to the 12-pin terminal strip on the top of the unit. First, remove the four screws at the co rners of the unit detaching the splash guard from the unit.
® ® WARNING: The voltages present on AC circui ts can cause electrocution. Before making any electrical connections to the RIM100, ensure that power is removed from all AC circuits that will be connected to the RIM100. Only restore AC power after all connections have been made to the RIM100 and the splash guard has been re-installed.
RIM100 User's Manual Power Switch RIM100 Screw Terminals Monitored DC Load + To DC - Breaker Panel Fuse Fuse User-Supplied Components 1 2 5 4 3 6 7 8 9 10 11 12 V1+ V2- V2+ V1- V3+ V3- V4+ V4- V5+ V5- V6+ V6- Figure 4 – DC Load Connection Diagram 2.
Revision 1.0 Page 7 ® ® 2.5.2 Channel #1 - #6 Mode You must configure the RIM100 as to whether a particular ch annel should be enabled. The allowable values for this parameter are as follows: • “Enable” (default) – Use this value if t he channel is being used to monitor a load.
RIM100 User's Manual Page 8 Revision 1.0 • Check the security of the c able connected to the NMEA 2000 ® co nnector, and tighten if necessary. • Check the security of all of the load connections on t he top of the unit and tighten if necessary.
Revision 1.0 Page 9 ® ® 5 Technical Specifications As Maretron is constantly impr oving its products, all specificat ions are subject to change without notice.
RIM100 User's Manual Page 10 Revision 1.0 Environmental Parameter Value IEC 60945 Classification Exposed Degree of Protection IP64 Operating Temperature -25°C to 55°C Storage Temperature -40°C to 70°C Relative Humidity 93%RH @40° per IEC60945-8.
® ® 7 Installation Template Please check the dimensions before using the fo llowing diagram as a template for drilling the mounting holes because the printing proc ess may have distorted the dimensions. Figure 5 – Mounting Surface Template Revision 1.
RIM100 User's Manual Page 12 Revision 1.0 8 Maretron (2 Year) Limited Warranty Maretron warrants the RI M100 to be free from defects in m aterials and workm anship for t wo (2) years from the date of original purchase.
Revision 1.0 Appendix A – NMEA 2000 Interfacing Page A1 ® ® Appendix A – NMEA 2000 ® Interfacing RIM100 NMEA 2000 ® Periodic Data Transmitted PGNs PGN 127501 – Binary Switch Bank Status The .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Maretron Run Indicator Module RIM100 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Maretron Run Indicator Module RIM100 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Maretron Run Indicator Module RIM100 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Maretron Run Indicator Module RIM100 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Maretron Run Indicator Module RIM100, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Maretron Run Indicator Module RIM100.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Maretron Run Indicator Module RIM100. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Maretron Run Indicator Module RIM100 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.