Manuale d’uso / di manutenzione del prodotto G12010R del fabbricante Makita
Vai alla pagina of 44
ISSUE EMD-GU2000 PRINTED IN JAPAN October 2004 CE-SK 100 Makita Corporation 3-11-8, Sumiyoshi-cho Anjo, Aichi 446-8502 Japan 3ZZ9020161 GENERATO R INSTRUCTIONS FOR USE アメリカ ISSUE EMD-GU1539 PR.
The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. W ARNING : NOTICE FEDERAL EMISSION COMPONENT DEFECT .
FEDERAL EMISSIONS COMPONENT DEFECT W ARRANTY EMISSIONS COMPONENT DEFECT WARRANTY COVERAGE - This emission warranty is applicable in all States, except the State of California Makita U.
*The replacement parts used for required maintenance services. *Consequential damages such as loss of time, inconvenience, loss of use of the engine orequipment, etc. *Diagnosis and inspection charges that do not result in warranty-eligible service being performed.
CALIFORNIA EMISSION CONTROL W ARRANTY ST A TEMENT (This warranty does not apply in any other state.) YOUR W ARRANTY RIGHTS AND OBLIGA TIONS The California Air Resources Board and Makita U.
MAKIT A , a distributor of small off-road equipment in the U.S., warrants to the owner of 2005 and later engines that the engine (1) has been designed, built, and equipped at the time of manufacture s.
WHA T IS NOT COVERED UNDER THIS W ARRANTY This warranty does not cover any emission-related part which malfunctions, fails, or is damaged due to alterations and/or modifications such as changing, adding, or removing parts.
REP AIR AND REPLACEMENT OF EMISSION-RELA TED P ARTS It is recommended that only engine replacement parts which have been authorized and approved by MAKIT A should be used in the performance of any warranty maintenance or repairs of emission-related parts.
Thank you for purchasing a Makita generator . This manual covers operation and maintenance of the Makita generators. All information in this publication is based on the latest production information available at the time of approval for printing.
■ Check that following accessories come with your Makita Generator . (1) Instruction for use (2) Servicing tools (3) Battery mounting bracket (See page 8 and 9.) ■ Be sure to replenish with engine oil. (See page 6 for details.) G12010R排対_GU2000 05.
CONTENTS 1. SAFETY PRECAUTIONS ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ 1 2. SPECIFICA TIONS ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ ・ 4 3.
− 1 − 1. SAFETY PRECAUTIONS Do not operate the generator near gasoline or gaseous fuel because of the potential danger of explosion or fire. Do not fill the fuel tank with fuel while the engine is running. Do not smoke or use open flame near the fuel tank.
− 2 − Operate the generator on a level surface. It is not necessary to prepare a special foundation for the generator . However , the generator will vibrate on an irregular surface, so choose a level place without surface irregularities.
− 3 − Engine becomes extremely hot during and for some time after operation. Keep combustible materials well away from generator area. Be very careful not to touch any parts of the hot engine especially the muffler area or serious burns may result.
2. SPECIFICA TIONS − 4 − Model G12010R Alternator Type Brush, Self-exciting, 2-pole, Single-phase Rated voltage 120V / 240V 9500 VA A.V.R type Engine Model EH65D Type Twin cylinder, Air-cooled, 4-stroke, Overhead valve engine Displacement 653 cm 3 Fuel Automotive unleaded gasoline Oil capacity 0.
3. COMPONENTS − 5 − SPARK PLUG CAP FUEL COCK BATTERY TANK CAP SPARK PLUG CAP OIL FILLER CAP MUFFLER OIL GAUGE CONNECTOR FOR REMOTE CONTROL ELECTRIC STARTER OIL DRAIN PLUG FUEL TANK CONTROL PANEL AIR CLEANER COOLING AIR INLET PORT OIL FILTER G12010R排対_GU2000 05.
− 6 − UPPER LEVEL LOWER LEVEL OIL GAUGE Oil gauge Upper level Lower level 4. PRE-OPERA TION CHECK CHECK ENGINE OIL Before checking or refilling oil, be sure generator is located on stable and level surface with engine stopped. 1) Remove oil level gauge and check the engine oil level.
1) Check fuel level at fuel level gauge. 2) If fuel level is low , refill with automotive unleaded gasoline only . This engine is certified to operate on automotive unleaded gasoline.
− 8 − Make sure you review each warning in order to prevent fire hazard. ■ Do not refill tank while engine is running or hot. ■ Close fuel cock before refueling with fuel. ■ Be careful not to admit dust, dirt, water or other foreign objects into fuel.
− 9 − RED CABEL RED CABEL LESS THAN 10.2 in. (260 mm) LESS THAN 6.7 in. (170 mm) LESS THAN 8.1 in. (205 mm) ① Butterfly nut ┓ ② Long bolt ┣ Accessory ③ Supporting arm ┛ parts ④ Terminals and nut ④ ① ③ ② Should the connection be made in incorrect manner , the engine will be broken.
CHECK COMPONENT P ARTS Check following items before starting engine: ■ Fuel leakage from fuel hose, etc. ■ Bolts and nuts for looseness. ■ Components for damage or breakage. ■ Generator not resting on or against any adjacent wiring. CHECK GENERA T OR SURROUNDINGS − 10 − Make sure you review each warning in order to prevent fire hazard.
(1) Make sure that the no-fuse breaker is off. (2) T urn the fuel cock to the vertical (open) position (3) T urn the key switch to the " ST ART " position. If the engine won't start, turn the switch back to "RUN" position and then wait for approximately 10 seconds to try it again.
− 12 − USING ELECTRIC POWER ■ Make sure that the appliance is switched OFF before connecting it to the generator . ■ Do not move the generator while it is running. ■ Be sure to ground the generator if the connected appliance is grounded. Failure to ground unit may lead to electrical shock.
− 13 − (1) AC APPLICA TION (a) Ground the generator , using the ground terminal located at the side of the panel. (b) Before starting the engine, check that the no-fuse breaker of the generator and the power switches of the appliances are turned off.
− 14 − up to 30A up to 30A up to 20A NEMA 5-20R NEMA L5-30R NEMA L14-30R NEMA 5-20P NEMA L5-30P NEMA L14-30P GFCI (Ground Fault Circuit Interrupter) Receptacle, duplex (REC1) Locking Receptacle (R.
− 15 − The duplex 120V receptacle is protected by a GFCI (Ground Fault Circuit Interrupter). GFCI shuts off the output current from the duplex 120V receptacle when a ground fault occurs in the generator or the appliance. Please note that other receptacles are not protected by GFCI.
− 16 − MAIN POWER LINE TRANSFER SWITCH UTILITY HIGH LINE CONNECTING BOX 240V RECEPTACLE (a) When connecting a Makita generator to a house wiring, generator output power must be taken from the 240V -4P receptacle.
− 17 − Utility high line M eter box Generator House circuit breaker XW Y X ( X )( Y ) ( G ) ( W ) WY XW Y Transfer switch 240V 4P- Receptacle 120V appliance 120V appliance 240V appliance OR Generator ( X ) ( Y ) ( G ) ( W ) 240V 4P- Receptacle W X Y (c) Operating the generator .
− 18 − (e) T urn on the switch of the appliance. PILOT LAMP NOTE : When the no-fuse breaker turns off during operation, the generator is over loaded or the appliance is defective. Stop the generator immediately , check the appliance and / or generator for overloading or detect and have repaired as necessary by Makita dealer or service shop.
− 19 − (3) IDLE CONTROL SWITCH IDLE CONTROL SWITCH automatically reduces engine speed when load is OFF , and automatically increases engine speed to rated r .p.m. when load is ON. IDLE CONTROL SWITCH provides fuel economy and low noise operation at no- load running.
− 20 − CLOSE CLOSE OPEN (6) Close the fuel cock. STOPPING THE GENERA TOR (1) T urn off the power switch of the electric equipment. (2) T urn the no-fuse breaker to off. (3) Unplug the cord from receptacle of the generator . STOP RUN STOP RUN START START (4) Allow the engine to run at no-load for about 3 minutes to cool down before stopping.
6. W A TT AGE INFORMA TION − 21 − Some appliances need a "surge" of energy when starting. This means that the amount of electrical power needed to start the appliance may exceed the amount needed to maintain its use.
− 22 − To determine the total wattage required to run a particular electrical appliance or tool, multiply the voltage figure of the appliance/tool by the amperage (amps) figure of same. The voltage and amperage (amps) information can be found on a name plate which is normally attached to electrical appliances and tools.
7. SP ARK ARRESTER − 23 − SP ARK ARRESTER In a dry or wooded area, it is recommendable to use the product with a spark arrester . Some areas require the use of a spark arrester . Please check your local laws and regulations before operating your product .
8. MAINTENANCE SCHEDULE − 24 − DAIL Y INSPECTION Before running the generator , check the following service items: Excessive vibration,noise Clean air cleaner element Safe surroundings Enough clea.
− 25 − (Periodic Maintenance Schedule table) *Note 1 : Initial oil change should be performed after first twenty (20) hours of operation. Thereafter change oil every hundred (100) hours. Before changing oil, check for a suitable way to dispose of old oil.
9. "HOW -T O" MAINTENANCE − 26 − OIL FILTER ENGINE OIL CHANGE ■ Initial oil change ・・・・・ After 20 hours of operation ■ Thereafter ・・・・・ Every 100 hours of operation 1. When changing oil, stop the engine and loosen the drain plug.
− 27 − ■ Urethane Foam cleaning W ash and clean the urethane foam in kerosene. Saturate in a mixture of 3 parts kerosene and 1 part engine oil, and then squeeze to remove excess oil.
− 28 − Spark plug NGK BPR5ES (CHAMPION RN11YC) CLEANING FUEL STRAINER Dirt and water in the fuel are removed by the fuel strainer . (a) Remove the strainer cup and throw away water and dirt. (b) Clean the screen and strainer cup with gasoline. (c) T ightly fasten the cup to main body , making sure to avoid fuel leak.
− 29 − CHECKING CARBON BRUSH If the brush become excessively worn, its contact pressure with the slip ring changes and causes a roughened surface on the slip ring, resulting in irregular generator performance. Check the brush every 500 hours or if generator performance is irregular .
10. PREP ARA TION FOR ST ORAGE − 30 − The following procedures should be followed prior to storage of your generator for a period of 6 months or longer . ■ Drain fuel from fuel tank and strainer (cup) carefully by disconnecting the fuel line. Gasoline left in the fuel tank will eventually deteriorate making engine-starting difficult.
11 . TROUBLESHOOTING − 31 − When generator engine fails to start after several attempts, or if no electricity is available at the output receptacles, check the possible causes in accordance with the following table.
12. WIRING DIAGRAM − 32 − Blk/Y 53 2 4 (AC output) ( AVR ) 1 CONTROL BOX Fuel cut Ignition coil Auto choke ( Bimetal ) Electric starter Oil pressure switch Regulator Magnetic switch Charge coil Ex.
ISSUE EMD-GU2000 PRINTED IN JAPAN October 2004 CE-SK 100 Makita Corporation 3-11-8, Sumiyoshi-cho Anjo, Aichi 446-8502 Japan 3ZZ9020161 GENERATO R INSTRUCTIONS FOR USE アメリカ ISSUE EMD-GU1539 PR.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Makita G12010R è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Makita G12010R - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Makita G12010R imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Makita G12010R ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Makita G12010R, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Makita G12010R.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Makita G12010R. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Makita G12010R insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.