Manuale d’uso / di manutenzione del prodotto EG511AE del fabbricante Makita
Vai alla pagina of 42
3ZZ9990516 EG series EG301A EG381A, EG381AE EG511A, EG511AE EG711A, EG711AE EG781A, EG781AE EG séries EG301A EG381A, EG381AE EG511A, EG511AE EG711A, EG711AE EG781A, EG781AE.
AIR INDEX Descriptive Term Applicable to Emissions Durability Period Moderate - 50 hours (engine from 0 to 80 cc) 125 hours (engine greater than 80 cc) Intermediate - 125 hours (engine from 0 to 80 cc.
EG781AE ce_GU6837 10.1.25 1:36 PM ページ002.
ENGLISH FOREWORD Thank you for purchasing a Makita generator . This manual covers operation and maintenance of the Makita generators. All information in this publication is based on the latest production information available at the time of approval for printing.
CONTENTS 1. SAFETY PRECAUTIONS ・・・・・・・・・・・・・・・・ 1 2. SPECIFICA TIONS ・・・・・・・・・・・・・・・・・・・ 3 3. COMPONENTS ・・・・・・・・・・・・・・・・・・・・ 4 4. PRE-OPERA TION CHECKS ・・・・・・・・・・・・・・・ 7 5.
1. SAFETY PRECAUTIONS − 1 − ENGLISH Please make sure you review each precaution carefully. Do not operate the generator near gasoline or gaseous fuel because of the potential danger of explosion or fire. Do not fill the fuel tank with fuel while the engine is running.
− 2 − Do not contact the generator to a commercial power line. Connection to a commercial power line may short circuit the generator and ruin it or cause electric shock hazard. Use the transfer switch for connecting to domestic circuit. WARNING Engine becomes extremely hot during and for some time after operation.
2. SPECIFICA TIONS − 3 − ENGLISH MODEL T ype Starting system L mm mm mm mL L kg Model T ype Vo ltage regulating system VA (W) Rated output Rated current AC Output Rated voltage Fuel tank capacity Engine oil capacity Spark plug Dry weight Specifications are subject to change without notice.
3. COMPONENTS − 4 − Fuel tank Fuel gauge Engine switch Choke lever Oil drain plug Oil gauge (oil filler) Spark plug cap Air cleaner Exhaust outlet Tank cap Fuel strainer ( Fuel valve ) Muffler cover Recoil starter Recoil starter handle Control panel EG301A, EG381A, EG381AE, EG51 1A, EG51 1AE EG781AE ce_GU6837 10.
− 5 − ENGLISH Control panel Fuel tank Fuel gauge Engine switch Recoil starter handle Choke lever Oil gauge (oil filler) Spark plug cap Air cleaner Muffler Tank cap Recoil starter Oil drain plug EG71 1A, EG71 1AE, EG781A, EG781AE EG781AE ce_GU6837 10.
− 6 − ï EG301A EG51 1A, EG51 1AE EG71 1A, EG71 1AE EG781A, EG781AE EG381A, EG381AE Pilot lamp AC receptacle 20A Earth ( ground ) terminal AC circuit breaker AC circuit breaker DC receptacle DC ci.
4. PRE-OPERA TION CHECKS − 7 − ENGLISH Upper level Oil filler cap (Oil gauge) Lower level CHECK ENGINE OIL Before checking or refilling oil, be sure generator is located on stable and level surface with engine stopped. ■ Remove oil filler cap and check the engine oil level.
− 8 − ■ Check fuel level at fuel level gauge. ■ If fuel level is low , refill with unleaded automotive gasoline. ■ Be sure to use the fuel filter screen on the fuel filter neck.
− 9 − ENGLISH CHECKING COMPONENT P ARTS Check following items before starting engine: ■ Fuel leakage from fuel hose, etc. ■ Bolts and nuts for looseness. ■ Components for damage or breakage. ■ Generator not resting on or against any adjacent wiring.
− 10 − GROUNDING THE GENERA TOR ■ To ground the generator to the earth, connect the grounding lug of the generator to the grounding spike driven into the earth or to the conductor which has been already grounded to the earth.
5. OPERA TING PROCEDURES − 11 − ENGLISH (a) T urn the Engine switch to the position "ON". (b) T urn the AC circuit breaker to the position "OFF".
− 12 − Pull briskly (e) [ Recoil starter model] Pull the starter handle slowly until passing the compression point (resistance will be felt), then return the handle to its original position and pull briskly . ■ If the engine fails to start after several attempts, repeat above procedures with choke lever returned to "OPEN" position.
− 13 − ENGLISH (g ) After the engine started, return the choke lever gradually to "OPEN" position. Choke lever CLOSE OPEN (h) W arm up the engine without a load for a few minutes.
− 14 − (a) Make sure the pilot lamp is turned on. (b) T urn off the switch (es) of the electrical appliance (s) before connecting to the generator .
− 15 − ENGLISH TABLE 1 NOTE : When the AC circuit breaker turns off during operation, the generator is over loaded or the appliance is defective. Stop the generator immediately , check the appliance and / or generator for overloading or detect and have repaired as necessary by Makita factory or authorized service center .
− 16 − (d) T urn the AC circuit breaker to the position "ON". (e )T urn on the switch of the appliance. ON ON OFF GFCI RECEPT ACLE After starting the engine, check the GFCI for proper functioning by the following test procedure. ■ Push blue TEST button, The red RESET button will pop out exposing the word TRIP .
− 17 − ENGLISH Switch position Lower V oltage Receptacle Higher V oltage Receptacle 120V Activated full rated output N.A 120/240V Activated half of rated output Activated full rated output FULL POWER SWITCH (Except EG301A) Select the voltage using the FULL POWER SWITCH in accordance with the electrical appliance.
− 18 − (2) DC APPLICA TION (Only for charging 12 volt battery) DC receptacle (Only for charging 12 volt battery) For charging 12 voltage battery , 12V -8.3A (100W) of maximum AC power can be taken out from the DC receptacle by means of the exclusive DC cable.
− 19 − ENGLISH ■ Do not use both AC and DC output at the same time. ■ Install correct positive (red) or negative (black) cable to the correct polarity on the battery . ■ Connect and disconnect DC cable with engine stopped. ■ An explosive hydrogen gas is discharged through vent holes in the battery during the charging process.
− 20 − STOPPING THE GENERA T OR (a) T urn off the power switch of the electric equipment and unplug the cord from receptacle of the generator . (b) T urn the AC circuit breaker to the "OFF" position. (c) Allow the engine about 3 minutes to cool down at no-load before stopping.
6. W A TT AGE INFORMA TION − 21 − ENGLISH Some appliances need a "surge" of energy when starting. This means that the amount of electrical power needed to start the appliance may exceed the amount needed to maintain its use.
VOL T AGE DROP IN ELECTRIC EXTENSION CORDS When a long electric extension cord is used to connect an appliance or tool to the generator , a certain amount of voltage drop or loss occurs in the extension cord which reduces the effective voltage available for the appliance or tool.
7. SP ARK ARRESTER − 23 − ENGLISH In a dry or wooded area, it is recommendable to use the product with a spark arrester . Some areas require the use of a spark arrester . Please check your local laws and regulations before operating your product .
DAIL Y INSPECTION Before running the generator , check the following service items: Excessive vibration,noise Clean air cleaner element Safe surroundings Enough clean engine oil Leakage of gasoline an.
− 25 − ENGLISH *Note: 1. Initial oil change should be performed after first twenty (20) hours of operation. Thereafter change oil every hundred (100) hours. Before changing oil, check for a suitable way to dispose of old oil. Do not pour it down into sewage drains, onto garden soil or into open streams.
ENGINE OIL CHANGE ■ Change engine oil every 100 hours. (For new engine, change oil after 20 hours.) (a) Drain oil by removing the drain plug and the oil filler cap while the engine is warm. Oil drain plug (b) Reinstall the drain plug and fill the engine with oil until it reaches the upper level on the oil filler cap.
− 27 − ENGLISH CLEANING AND ADJUSTING SP ARK PLUG (a) If the plug is contaminated with carbon, remove it using a plug cleaner or wire brush. (b) Adjust the electrode gap to 0.6 to 0.7 mm (0.024 to 0.028 in.). Gap 0.6 to 0.7 mm ( 0.024 to 0.028 in.
− 28 − This is done because if the length of the brush gets any shorter , its contact pressure with the slip ring will decrease, resulting in a drop in generator efficiency and the output voltage. Check the brush every 500 hours to confirm its length.
− 29 − ENGLISH Brush Maintenance Essentials (Disassembly and Assembly) Disassembly 1. Remove the two flange bolts (M5 x 20), then remove the bracket cover . 2. Remove the two flange bolts (M5 x 16), then remove the brush. Assembly 1. While pressing the brush against the slip ring, secure it (1.
10. PREP ARA TION FOR ST ORAGE − 30 − The following procedures should be followed prior to storage of your generator for periods of 6 months or longer . ■ Drain fuel from fuel tank carefully by disconnecting the fuel line. Gasoline left in the fuel tank will eventually deteriorate making engine- starting difficult.
11 . TROUBLESHOOTING − 31 − ENGLISH When generator engine fails to start after several attempts, or if no electricity is available at the output socket, check the following chart.
12. WIRING DIAGRAM − 32 − PL AC winding 2 AC winding 1 Y Y Grn/Y Org Y/R Blk RR R Blu Blu Gry Grn/Y Grn/Y Blk Ignition coil Oil sensor switch Spark plug Oil sensor unit Y Blk W W W Brn Y Y.
− 33 − ENGLISH PL AC winding 2 AC winding 1 Y Y Grn/Y Org Y/R Blk RR R Blu Blu Gry Grn/Y Grn/Y Blk Ignition coil Oil sensor switch Spark plug Oil sensor unit Y Blk WW W Brn Y Y Blu Brn Brn Y Blu B.
− 34 − Org Y/R Blk Blk Ignition coil Oil sensor switch Spark plug Oil sensor unit Y AC winding 2 AC winding 1 Y Y Grn/Y Brn Y Y Brn Brn Y Blu Blu Brn ROTOR S TATO R Slip ring Sub coil DC winding A.
− 35 − ENGLISH PL AC winding 2 AC winding 1 Grn/Y Org Y/R Blk RR Blu Blu Gry Grn/Y Grn/Y Blk Ignition coil Oil sensor switch Spark plug Oil sensor unit Y Blk W W W Brn Blu Blu Blu Blu R Grn Grn W .
− 36 − PL GENERA TOR CONTROL BOX ENGINE Org Y/R Blk Blk Ignition coil Oil sensor switch Spark plug Oil sensor unit Y AC winding 2 AC winding 1 Blu Blu Grn/Y Brn Blu Blu R Grn Grn W W W Brn ROTOR S.
Makita Corporation 3-11-8, Sumiyoshi-cho Anjo, Aichi 446-8502 Japan ISSUE EMD-GU7037 PRINTED IN JAPAN May 2010 IMPRESO EN JAPÓN Mayo 2010.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Makita EG511AE è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Makita EG511AE - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Makita EG511AE imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Makita EG511AE ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Makita EG511AE, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Makita EG511AE.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Makita EG511AE. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Makita EG511AE insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.