Manuale d’uso / di manutenzione del prodotto SC36A del fabbricante Majestic
Vai alla pagina of 24
SR/SC Series "A" W oodburning Fireplace For Models: SC36A, SR36A SC42A, SR42A For use in U.S./Canada Underwriter's Laboratories Report No. MH6018 DO NOT DISCARD THIS MANUAL: Retain for future use. 948 SR cover 1 1/18/97 948 SC cover 1 1/18/97 7412948 7/08 Rev .
2 SR/SC Series "A" W oodb ur ning Fireplace 7412948 Safety Information PLEASE READ THIS MANUAL BEFORE INST ALLING AND USING FIREPLACE. IMPORT ANT : Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty .
3 SR/SC Series "A" W oodb ur ning Fireplace 7412948 5/8" (16mm) 1/2" (13mm) 1/2" 36" (914mm) 38 " (971mm) 40" (1016mm) 5/8" (16mm) 22 &.
4 SR/SC Series "A" W oodb ur ning Fireplace 7412948 5/8" (16mm) 1/2" (13mm) 1/2" 42" (1067mm) 38 " (971mm) 46" (1 168mm) 5/8" (16mm) 22 .
5 SR/SC Series "A" W oodb ur ning Fireplace 7412948 Chase Installation Insulation methods shown are optional for cold climate, not a requirement for unit operation.
6 SR/SC Series "A" W oodb ur ning Fireplace 7412948 Chimney Requirements - Offset Installations 0 0 0 0 0 3" 1 1" 1 0 0 0 0 8 ¹⁄₄ " 20" 0 1 0 0 0 1 1 ¹⁄₄ ".
7 SR/SC Series "A" W oodb ur ning Fireplace 7412948 L 1 L 1 L T MODEL SK 2 W ALL CHIMNEY TOT AL LENGTH (L T ) INST ALLED LENGTH (L 1 ) SK81 SK818 SK83 SK84 1 1 " 17 .
8 SR/SC Series "A" W oodb ur ning Fireplace 7412948 Insulating Fireplace Enclosure for Cold Climates If you live in a cold climate, it is not required but highly recommended that you insulate fireplace enclosure to eliminate cold air penetration as much as possible.
9 SR/SC Series "A" W oodb ur ning Fireplace 7412948 Framing Framing can be constructed before or after the fireplace is set in place, however , most installers build the frame before setting the fireplace. Frame fireplace with 2 x 4 lumber or heavier materials.
10 SR/SC Series "A" W oodb ur ning Fireplace 7412948 Straight-Up Chimney Installation T o mark the centerline of the flue, put the fireplace in final position and measure out from the wall: 9 ¹⁄₄ " (235mm). Mark a spot on the ceiling directly above the fireplace.
1 1 SR/SC Series "A" W oodb ur ning Fireplace 7412948 NOTE: Safety strips are not required over noncom- bustible floors where all supports at the base of the fireplace are noncombustible. Four (4) nailing flanges are incorporated on each cor- ner of the surround.
12 SR/SC Series "A" W oodb ur ning Fireplace 7412948 Continue installing the pipe as required until pipe is installed up through the ceiling. At this point, you must install a firestop spacer . Installing the Firestop Spacer in the Ceiling Hole A firestop spacer is used to keep pipe spaced properly and required for safety .
13 SR/SC Series "A" W oodb ur ning Fireplace 7412948 NOTE: In the U.S., it is a good idea, although not al- ways required, to install an attic insulation shield where blown-in insulation is planned to be used in the attic. Install the attic insulation shield with the flanges on its base extending down into the framing hole.
14 SR/SC Series "A" W oodb ur ning Fireplace 7412948 Installing T op Housing or T ermination Follow the installation instructions provided with the chimney termination you have selected. Installing Chimney In a Chase Refer to Page 5, Figure 5 for an illustration of a typical chase installation.
15 SR/SC Series "A" W oodb ur ning Fireplace 7412948 MA81 rev . 8/5/97 1 " Ref. Combustible materials are permitted within a shaded area shown in Figure 23 titled Minimum W all Clearances. * ** MA81 Fig. 22 Combustible mantle clearances.
16 SR/SC Series "A" W oodb ur ning Fireplace 7412948 Hearth Installation A hearth extension is required to protect a combustible floor in front of the fireplace. Refer to Figure 23 for mini- mum dimensions and mounting detail. NOTE: Hearth Extension must not cover the air inlet opening of a fireplace.
17 SR/SC Series "A" W oodb ur ning Fireplace 7412948 COMMON MA TERIALS AND F ACTORS MA TERIAL K* R MINIMUM THICKNESS EH2416 Common Brick 0.458 5.0 1.09 0.50 in.** 0.10 5.46 in.** (MHSC) R V alue is for 1/2 inch. * Units of K = BTU/SQ FT/HR/˚F/IN ** Thickness of Listed Material FP533ADD Addendum 6/1/99 djt 8/4/99 changed .
18 SR/SC Series "A" W oodb ur ning Fireplace 7412948 Installing Line for Gas Logs MHSC fireplaces are designed to accept a 1/2" (13 mm) gas line for installation of an approved gas appliance. (MHSC manufactures a wide variety of gas logs for use in MHSC fireplaces.
19 SR/SC Series "A" W oodb ur ning Fireplace 7412948 1 2 3 4 5 6 a b c 7 8 9 10 1 1 12 948 SR/SC parts 5/16/00 djt d 14 13 e MHSC reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
20 SR/SC Series "A" W oodb ur ning Fireplace 7412948 The following accessories for this appliance are available from your local Majestic Fireplaces distributor . Should you need additional information beyond what your distributor can furnish, contact: MHSC, 149 Cleveland Drive, Paris, KY 40361, Attn: T echnical Services.
21 SR/SC Series "A" W oodb ur ning Fireplace 7412948 Chimney Components Round T op T ermination T op used to terminate chimney at roof. RL TSK8 (Flashing not included.) Round T op T ermination - T op used to terminate chimney at chase. RL TSK8L Extended (Flashing not included.
22 SR/SC Series "A" W oodb ur ning Fireplace 7412948 Chimney Collar Enclosure Installs on the "over the chimney collar" of the CCE-SK fireplace; provides outside air to assist in cooling the chimney system. Attic Insulation Shield Used to prevent insulation from coming in AIS-SK contact with the chimney system.
23 SR/SC Series "A" W oodb ur ning Fireplace 7412948 LIMITED W ARRANTY Factory-Build Fireplace and Components (Except Blowers) What is Covered and For How Long Five-Y ear Coverage: For five.
MHSC 149 Cleveland Drive • Paris, Kentucky 40361 www .mhsc.com.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Majestic SC36A è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Majestic SC36A - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Majestic SC36A imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Majestic SC36A ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Majestic SC36A, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Majestic SC36A.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Majestic SC36A. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Majestic SC36A insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.