1 m Vermont Castings Jefferson Vent Free Gas Heater 20003447b / 0701 INST ALLER / CONSUMER SAFETY INFORMA TION PLEASE READ THIS MANUAL BEFORE INST ALLING AND USING APPLIANCE. W ARNING! IF THE INFORMA TION IN THIS MANUAL IS NOT FOLLOWED EXACTL Y , A FIRE OR EXPLOSION MA Y RESUL T CAUSING PROP- ERTY DAMAGE, PERSONAL IN- JUR Y OR LOSS OF LIFE.
2 2 Vermont Castings Jefferson Vent Free Gas Heater Table of Contents Heater Dimensions ............................... 3 Safety Information ................................ 4 General Information ............................. 5 Installation Requirements .
3 m Vermont Castings Jefferson Vent Free Gas Heater Fuel NG LP Manifold Pressure Min./Max. 1.7”/3.5” 5.4”/1 1.0” (RP) 4.4”/10.0” (MP) Min. Inlet Supply Pressure for adjustment: 5.5”w .c. 1 1.0”w .c. Max. Inlet Supply Pressure for adjustment: 14.
4 4 Vermont Castings Jefferson Vent Free Gas Heater Safety Infor mation W ARNINGS IMPORT ANT : READ THIS OWNER’S MANUAL CAREFULL Y AND COMPLETEL Y BEFORE TR YING TO AS- SEMBLE, OPERA TE OR SER VICE THIS HEA TER.
5 m Vermont Castings Jefferson Vent Free Gas Heater General Infor mation V ent Free Features The JUVS Gas Heater is an unvented gas appliance tested and listed to the ANSI standard Z21.1 1.2.2000. The V ent Free Gas Heater is configured to use Natural Gas, (JUVSRN, JUVSMN ) or Propane (JUVSRP , JUVSMP).
6 6 Vermont Castings Jefferson Vent Free Gas Heater W ARNING This heater must have fresh air for proper opera- tion. If it does not, poor fuel combustion could result. Read the following instructions to ensure proper fresh air supply for this and other fuel- burning appliances in your home.
7 m Vermont Castings Jefferson Vent Free Gas Heater 4. Compare the maximum BTU/hour rating the space can support with the total BTU/hour used by the appli- ances.
8 8 Vermont Castings Jefferson Vent Free Gas Heater Clearance Requirements Minimum Clearances to Combustible Materials Maintain clearance, (empty space), between combus- tible materials and the heater as specified. Hearth Requirements The JUVS must be installed on rigid flooring.
9 m Vermont Castings Jefferson Vent Free Gas Heater Optional Fan Kit Installation (2960/FK28) 1. Attach the fan to the rear shroud by engaging the upper flange of the fan skirt under the lower edge of the shroud and secure the skirt with the four screws and one star washer provided.
10 10 Vermont Castings Jefferson Vent Free Gas Heater Connect the Gas Supply Line Check the Rating Plate attached by a steel cable to the firebox, to confirm that you have the appropriate firebox for the type of fuel to be used. This appliance should only be connected by a qualified gas technician.
11 m Vermont Castings Jefferson Vent Free Gas Heater Install ON/OFF Switch (R Models only) The switch assembly parts are found in the parts bag. 1. Attach switch assembly to left rear side of stove shroud using two screws and existing holes in shroud.
12 12 Vermont Castings Jefferson Vent Free Gas Heater Operation PILOT ON OFF PILOT ADJ L O H I TPTH TH TP Piezo Ignitor Gas Control Knob Regulator Control Knob HV104 Fig.
13 m Vermont Castings Jefferson Vent Free Gas Heater Fig. 23 Proper flame pattern with Regulator in HIGH position. ST1 16 Thermopile* Fig. 24 Correct Pilot Flame. (*JUVSM pilots do not have Thermopile) Pilot Orifice ST1 17a Lifting Flame Weak Flame Fig.
14 14 Vermont Castings Jefferson Vent Free Gas Heater 4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. Turn off all electrical power to the fireplace.
15 m Vermont Castings Jefferson Vent Free Gas Heater Maintenance W ARNING Dust and debris accumulation can result in poor performance. Inspect the valve compartment, burner parts and log set frequently and clean these parts monthly or as often as accumulation warrants.
16 16 Vermont Castings Jefferson Vent Free Gas Heater T roubleshooting Follow these procedures in the order presented. W ARNING TURN OFF HEA TER AND ALLOW T O COOL COMPLETEL Y BEFORE SERVICING. CONDITION POSSIBLE CAUSE SOLUTION No spark at pilot when Ignitor is operated.
17 m Vermont Castings Jefferson Vent Free Gas Heater Troubleshooting cont’d. CONDITION POSSIBLE CAUSE SOLUTION Pilot lights but flame goes out when Control Knob is released. 1. Control Knob not fully depressed or held in long enough. 2. Gas supply line shut-off valve is not fully open.
18 18 Vermont Castings Jefferson Vent Free Gas Heater W ARNING If you smell gas: • Shut off gas supply • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor ’ s phone.
19 m Vermont Castings Jefferson Vent Free Gas Heater Jefferson V ent Free Gas Heater Item/Model Number Part Number 1. Log Set Complete 20003482 1a. Back Log 20003483 1b. Upper Left Log 20003487 1c. Upper Right Log 20003486 1d. Left Log 20003485 1e. Right Log 20003484 2.
20 20 Vermont Castings Jefferson Vent Free Gas Heater Item/Model Number Part Number JUVS (continued) 10. Wire Harness 57265 1 1. Handle Damper - Maplewood 1600664 12. Front Handle Assembly (Brass) 5004240 13. Right Log Bracket 20003019 14. Left Log Bracket 20003020 15a.
21 m Vermont Castings Jefferson Vent Free Gas Heater W arranty Limited Three Y ear W arranty The V ermont Castings, Majestic Products Company (Manufac- turer) warrants that this V ent Free Gas Heater .
22 22 Vermont Castings Jefferson Vent Free Gas Heater © The V ermont Castings Majestic Products Company 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7885 www.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Majestic Appliances 3101 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Majestic Appliances 3101 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Majestic Appliances 3101 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Majestic Appliances 3101 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Majestic Appliances 3101, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Majestic Appliances 3101.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Majestic Appliances 3101. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Majestic Appliances 3101 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.