Manuale d’uso / di manutenzione del prodotto HCB 2062 del fabbricante Liebherr
Vai alla pagina of 17
HC/HCB 20 7083 319-00 Installation Instructions For Fully Integrated NoFr ost Combined Refrigerator-Freezers HC 2062 HCB 2062.
2 PLEASE READ AND FOLLOW THESE INSTRUCTIONS These instructions contain Warning and Caution statements. This inf or mation is impor tant f or safe and efficient installation.
3 I nst alla tIon G uIdelInes ELECTROCUTION HAZARD Electrical grounding required. This appliance is equipped with a three-prong (grounding) polarized plug f or your protection a gainst possible shock hazar ds. • Do not remove the round gr ounding prong fr om the plug.
Unit Dimensions - Figure 1 Unit V enting - Figure 3 HC/HCB 20 appliances do not require any v entilation openings in the cabinet. The required airflow is directed through the toe kic k area. It is impor tant to use the provided co ver grille f or the v entilation opening.
Cabinet Opening Dimensions - Figure 4 Figure 4 IMPORT ANT Do not install the shut-off v alve behind the appliance . IMPORT ANT The free length of the water supply line m ust be at least 31-1/2" (800 mm) when the tube comes out of the pre- scribed opening.
Figure 5 The panels should be at least 5/8 inch (16 mm) thick to allo w the connecting rails to be f astened to them. IMPORT ANT The maximum panel thic kness is 3/4" (19 mm).
Figure 6 IMPORT ANT The maximum panel thic kness is 3/4" (19 mm). Cabinet Opening C Refrigerator door panel D 80" (2032 mm) 45 - 3/4" (1162 mm) 84" (2134 mm) 49 - 3/4" (1264 m.
Secure the appliance in place so it does not tip f orward when the fully stock ed door is opened. The anti tipping brac ket is provided with the appliance . 1. Mark the center line of the appliance on the back wall. Align the anti tipping brac ket center to this line.
Figure 12 Cover strips - Figure 12 Bef ore connection to the water supply , the cov er strips provided must be fitted to the appliance . It is necessar y because the appliance will be mo v ed into its recess.
10 I ce m aker Figure 14 • The solenoidvalv e has a metr ic R3/4 male connector . A R3/4 (metric) to a 1/4" OD adapter is supplied with the ice maker . • Inser t thewater strainerprovided into the OD adapter with the cavity downw ards.
11 I ce m aker Figure 16 Figure 17 9. Open the shut-off v alve f or the water supply and check the entire w ater system for leaks . IMPORT ANT After star ting up the appliance, the w ater pipe system must be purged of an y air . Ref er to chapter "Bleeding the ice maker" in the operating instructions.
Fasten the appliance in the r ecess - Figure 20 F asten the appliance in the recess through the upper and low er hinges of the refr igerator doors . Use 2 screws f or each hinge. screws (4 x 16 mm) Befor e mounting the door panels - Figure 21 Remov e cov er 1 and unscrew the upper attachment brac ket 2 of both refrigerator doors.
Mounting the attachment brackets onto the door panels - Figure 22 Mark lines on the refr igerator door panels as sho wn in Figure 22. Align the dismounted brac kets of the refrigerator doors to the lines on the refrigerator door panels as shown in Figure 22 a.
Mounting the r efrigerator door panels - Figures 24 - 33 The description is for one panel only . The procedure is the same f or both panels. 1. Open the refrigerator door and hang the panel on the adjusting bolts (Figure 24) . 2. Scre w on the hex n uts to the adjusting bolts and finger tighten temporarily (Figure 24) .
T o mak e it possible to f asten the refr igerator panel at the bottom the soft-stop cylinder must be dismantled. 5. Gr asp the soft-stop cylinder and pull down (Figure 26) . The soft-stop cylinder retracts in the detached state. Figure 26 Figure 27 6.
13. Extend the soft-stop cylinder and connect with the ball stud (Figure 32) . Figure 32 Figure 33 14. Click co v er into place (Figure 33) . Figure 31 12. F asten the refr iger ator panel using the same screws that held the lo wer brac ket bef ore remov al (Figure 31) .
Mounting the ventilation grille - Figure 34, 35 1. Pull out the bottom freez er draw er . 2. Remo ve the b lue protection film from the dust filter provided and inser t the filter into its opening in the toe kick area as sho wn in Figure 34 . Attach the filter at the bottom, press down the button and clic k into place.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Liebherr HCB 2062 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Liebherr HCB 2062 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Liebherr HCB 2062 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Liebherr HCB 2062 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Liebherr HCB 2062, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Liebherr HCB 2062.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Liebherr HCB 2062. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Liebherr HCB 2062 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.