Manuale d’uso / di manutenzione del prodotto PCS150R del fabbricante LG Electronics
Vai alla pagina of 26
© Copyright 201 1, LG Electronics U.S.A., Inc. PCS150R Pro:Centric™ Server Installation & Setup Guide W arranty P/N: 206-4157 (Rev A).
2 206-4157 W ARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE P ARTS INSIDE. REFER TO QUALIFIED SERVICE PERSONNEL.
3 206-4157 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water . 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufac- turer's instructions.
4 206-4157 (Continued from previous page) 21. Damage Requiring Service Unplug this product from the wall power out- let and refer servicing to qualied service personnel under the following conditions: a. If th e po we r- su pp ly c or d or pl ug is d am ag ed.
5 206-4157 (Continued from previous page) B. Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. T o ventilate the system nor- mally and avoid overheating, leave at least 1 inch (2.
6 206-4157 S a f e t y W a r n i n g s ....................... 2 Important Safety Instructions. . . . . . . . . . . . 3 – 5 T able of Contents / Setup Checklist . . . . . . . . 6 PCS150R Product Description . . . . . . . . . . . . 7 Rear and Front Panel Overviews .
7 206-4157 PCS150R Product Description The PCS 150 R Pr o:Ce ntri c serv er is a stan d-al one , re mote ly-c ont roll ed pro cess or and con tro ller for the Pro :Cen tric sys tem . This device can be used to capture data from an Internet source, assemble the data as display pages, and output the pages in DTV format over an ASI or RF interface.
8 206-4157 Rear and Front Panel Overviews PO WER -I N 12 V D C / 4 .0 A ETH ERN ET -1 / ET HER NET -0 ASI-OUT RS-232 RS-232 Port ASI Out NETWORK (Ethernet) Ports RF-OUT USB ..... .... USB Ports RF Out Power Supply/Cord Disconnect Device The AC mains plug is used as the disconnect device.
9 206-4157 Rack-mount Considerations A. Elevated Operating Ambient If installed in a closed or multi-unit rack as sem bly , the oper ati ng am bie nt te mpe ratu re of th e rack envi ron men t may be gre ate r tha n ro om am bie nt.
10 206-4157 System Setup Combiner RF Coaxial Cable RF Cable ASI Out PCS150R IF Out QAM Modulator ASI In IF In RF Out DTV Upconv er ter Network Room Receiver Room Receiver Room Receiver RF Distribution.
1 1 206-4157 T ypical System Installation (see also T ypical Setup Flow Charts and VPN Network Connections Overview diagrams) 1. If your system is using ASI output, make the following two connections; otherwise, go to step 2. • Connect a 75 ohm BNC-to-BNC coaxial cable between ASI OUT on the PCS150R and ASI IN on the modulator .
12 206-4157 (Continued from previous page) 6. Plug the AC power cord into a powered AC line receptacle. When power is applied, the ST A TUS LED on the PCS150R front panel will light, and you will see boot-up messages on the PC.
13 206-4157 This section describes configuration options for the PCS150R. Note: Before you proceed with any additional server configuration, the system should be installed and operating as described in the system setup procedure on pages 1 1 and 12. Also note that configuration updates will generally require that you reset the PCS150R.
14 206-4157 Example: PCS150R Main Menu - -- -- - -- - M ai n Me nu - -- -- - -- - in fo S ys te m i nf or ma ti on vi de o C on fi g ur e vi de o pa ra me t er s se ti p S et up TC P /I P tz T im ez o.
15 206-4157 Configure Video Parameters This option enables you to view current settings and/or configure new settings, as required. 1. Log in to the PCS150R as described on page 13.
16 206-4157 PCS150R Configuration Options (Cont.) (Continued from previous page) • Elementary PID: There are four Elementary PIDs. T ype 4 , 5 , 6 , or 7 , depending on which Elementary PID you wish to change, and press Enter . At the En te r n ew va lu e f or E le me n ta ry P ID # [ ]: prompt, type the new Elementary PID and press Enter .
17 206-4157 PCS150R Configuration Options (Cont.) (Continued from previous page) 3. Either: • Continue with step 4 for information on modifying the conguration a PCS150R Ethernet port. • Go to step 9 for information on modifying the DNS conguration.
18 206-4157 PCS150R Configuration Options (Cont.) (Continued from previous page) 10. When you are nished with network conguration, type exit at the Network Conguration Menu > prompt.
19 206-4157 PCS150R Configuration Options (Cont.) (Continued from previous page) 4. The system displays the following prompt for a location, followed by a list of options: P l e a s e i d e n t i f y a l o c a t i o n s o t h a t t i m e z o n e r u l e s c a n b e s e t c o r r e c t l y .
20 206-4157 PCS150R Configuration Options (Cont.) Change the Login Password 1. Log in to the PCS150R as described on page 13. 2. At the Co m ma nd > prompt, type pwd and press Enter . The system prompts for the current password: C ha ng i ng pa ss w or d fo r ad mi n O ld pa ss w or d: 3.
21 206-4157 PCS150R Configuration Options (Cont.) Update PCS150R Application or OS Software via Serial Link Cau tion : Do NOT init iate simu ltan eous menu ses sions whi le a softw are upd ate is in pro gres s.
22 206-4157 PCS150R Configuration Options (Cont.) (Continued from previous page) The system will display progress messages as well as the result of the update process (which may take several minutes). 4. When the update is successfully completed, the system may prompt you to reset the PCS150R.
23 206-4157 T roubleshooting / Specifications Specifications Dimensions Height: 1.692 inches (42.977 mm) Width: 19.0 inches (482.6 mm) (for EIA standard 19-inch rack mount) Depth: 8.
24 206-4157 Document Revision History / Notes Notes Document Revision History Date Description May 201 1 Revision A: New document Product documentation is available online at: www .
25 206-4157 The follo wing GPL ex ecuta bles and L GPL lib rarie s use d in thi s prod uct a re su bject to t he GP L V ers ion 2 .0/LG PL V er- sio n 2.1 Licen se Agree ments : GPL EXECUT ABLES: Lin ux ke rnel 2.6.3 3, L TI B 10. 1.1, bas h-2.05 b, bu sybox -1.
206-4157 Revision A Copyright 201 1, LG Electronics U.S.A., Inc. Broa dcas t Prod ucts We lcom e to the LG fam ily! W e bel ieve tha t you wi ll be p lease d with your n ew PCS 150R P ro:C entri c Serv er . Pleas e read thi s warr anty caref ully , it is a “LIM ITED WA RRAN TY” as def ined under Feder al Law .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il LG Electronics PCS150R è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del LG Electronics PCS150R - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso LG Electronics PCS150R imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul LG Electronics PCS150R ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il LG Electronics PCS150R, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del LG Electronics PCS150R.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il LG Electronics PCS150R. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo LG Electronics PCS150R insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.